News

On this page, we list the main changes that affected ERIS and this web site.

Observatory News

General news concerning the status of the obervatory and UT4 can be found here

Timeline of instrument status

The following table describes the events affecting the quality or the measurement of data obtained with ERIS. Its content can be downloaded as a Comma Separated Values file.

This timeline is complete as of August 22nd, 2022.

For each event, the Start Date column indicates when the event took place. Some events cannot be defined by a single instant, but extend over sometimes several days, weeks or months. Operation with the instrument may continue while the event occurs, in which case the Ongoing flag is set. If the event had ended, the Ongoing flag is lowered and End Date is given. The Type column indicates the characteristic(s) of the event: Earthquake, Maintenance, Upgrade, Element failure, Intervention, Pipeline installation at QC, Change of nominal values or thresholds, Modification of configuration file of this database, or Other. The Instrument Modes column indicates the affected mode. The column KPI lists the affected quality control parameters identified as Key Performance Indicators (i.e., parameters following the most critical quantities); the column non-KPI lists the other affected Quality Control parameters. The Calibration Raw Types column indicates the raw types of the affected calibrations. The Calibration Breakpoint flag indicates if calibrations obtained before the event cannot be used for science data obtained after the event or if calibration data obtained after the event cannot be used with science data obtained before the event. The Comment column provides more details on the event. The History column allows one to see possible past information on the entry.

The Quality Control pages for ERIS can be accessed through the QC overview page.

Announcements

  • 31 Mar 2026: NIX is available for service and visitor mode observations with the Ks filter only, as the mechanism has been temporarily fixed in this position.
  • 09 Feb 2026: NIX is unavailable for service and visitor mode observations due to a fault with the filter wheel mechanism.
  • 29 Jan 2026: NIX is again available for service and visitor mode observations.
  • 19 Jan 2026: SPIFFIER is again available for service and visitor mode observations. NIX remains unavailable due to a new issue with the image selector wheel mechanism.
  • 07 Jan 2026: ERIS is unavaiable for service and visitor mode observations due to planned maintenance activities. The issues with NIX were resolved; however, the recommissioning could not be completed before these maintenance activities were due to start. SPIFFIER should be available again on January 19th, and NIX on January 27th.
  • 28 Nov 2025: NIX is unavailable for service and visitor mode observations due to a fault with the filter wheel mechanism and the optical bench heater.
  • 16 Jul 2025: NIX is again available for service and visitor mode observations.
  • 29 Jun 2025: NIX is unavailable for service and visitor mode observations due to a fault with the filter wheel mechanism.
  • 23 Apr 2025: NIX is again available for service and visitor mode observations.
  • 19 Apr 2025: NIX is unavailable for service and visitor mode observations due to a fault with the filter wheel mechanism.
  • 01 Feb 2025: New modes/functionalities offered for P116:
    • Pupil tracking for SPIFFIER
    • Pupil tracking for standard NIX imaging
    • Spider pupil plane mask for long-wavelength NIX imaging using pupil tracking
  • 30 Jan 2025: NIX is again available for service and visitor mode observations.
  • 25 Jan 2025: SPIFFIER is again available for service and visitor mode observations. NIX remains unavailable until at least January 30th pending a successful re-commissioning.
  • 20 Dec 2024: NIX will remain unavailable until the end of January 2025. An intervention is planned to start January 8th, with SPIFFIER being available again from January 22nd and NIX from January 30th, both subject to a succesful re-intergration of NIX and re-commissioning of both arms of the instrument.
  • 28 Oct 2024: SPIFFIER is again available for service and visitor mode observations. NIX will remain unavailable for the foreseable future.
  • 24 Oct 2024: ERIS is unavailable for service and visitor mode observations. NIX will remain unavailable for several months while a component inside the cryostat is repaired. It is planned to remount ERIS with a dummy mass instead of NIX such that SPIFFIER can be offered again. If this is feasible, it is hoped SPIFFIER will be available again mid-November.
  • 12 Oct 2024: NIX is unavaiable for service and visitor mode observations due to a fault with the optical bench heater within the cryostat.
  • 05 Apr 2024: ERIS is again available for both service and visitor mode observations.
  • 30 Mar 2024: ERIS is unavailable for service and visitor mode observations as it is being dismounted to investigate a leak discovered coming from above the instrument.
  • 30 Jan 2024: ERIS is again available for service mode observations.
  • 17 Jan 2024: ERIS is unavailable until the end of the month as it is being dismounted to investigate persistent problems with the AO periscope.
  • 11 Sep 2023: SPIFFIER is again available for service mode observations.
  • 15 Aug 2023: SPIFFIER is unavailable for service mode observations due to a technical issue with the grating wheel.
  • 13 Aug 2023: New modes/functionalities offered for P113:
    • NIX focal plane coronagraphy (FPC)
    • NIX long-slit spectroscpy (LSS)
  • 10 Mar 2023: An updated version of the ERIS ETC has been released (changelog).
  • 01 Mar 2023: New modes/functionalities offered for P112 (limits for approved P111 programs are not changed):
    • NGS AO limit changed from RP=1-11 to RP<11
    • LGS AO limit changed from RP=7-17 to RP=7-18, the BP<19 limit remains the same
    • Sparse aperture mask (SAM) interferometry
    • Non-sidereal and differential tracking
    • Seeing enhancer mode for targets without suitable tip-tilt stars
    • NIX windowing with four preset subarray sizes
  • 02 Dec 2022: ERIS science verification