NAME lamp_chk_qc.prg
VERSION 2.0 -- adapted for WAVE and FLAT for new pipeline
SYNTAX MIDAS
CALL measureQuality
from $DFS_PRODUCT/LAMP_CHECK/$DATE:
inmidas -P -j "@@ $DFO_PROC_DIR/lamp_chk_qc.prg $date $PF"
INSTRUMENT FORS2
RAWTYPE LAMP_CHECK
PURPOSE plots product WAVE and FLAT files for FORS2 QC assessment; the plots are later reviewed within certifyProducts. The plots are stored as Postscript file in $DFO_PLT_DIR.
PROCINPUT products: reduced WAVE/FLAT image
QC1TABLE trending | table(s) in QC1 database:
fors2_lamp_chk
TRENDPLOT trending | HealthCheck plot(s) associated to this procedure:
trend_report_LAMP_FlatBlue12_HC.html | trend_report_LAMP_FlatBlue34_HC.html | trend_report_LAMP_FlatRed34_HC.html | trend_report_LAMP_Ar12_HC.html | trend_report_LAMP_Ne12_HC.html | trend_report_LAMP_HeHgCd_HC.html
QC1PAGE trending | associated documentation:
QC1PLOTS
top

LAMP_Ar1.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_Ar2.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_Ne1.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_Ne2.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_He1.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_HgCd2.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatBlue1.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatBlue2.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatBlue3.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatBlue4.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatRed3.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error

LAMP_FlatRed4.png
top panel: date; name of product(red), setup parameters (filter, grism, slit, lamp)
bottom panel: QC1 parameters - integrated flux per second and its rms error
QC1PARAM QC1 parameters written into QC1 table:
QC1db names: flux | flux_err
FITS key names: LAMP FLUX | LAMP FLUXERR
ALGORITHM
CERTIF Reasons for rejection:
- none; data are used for lamp monitoring only
COMMENTS
top [2015-11-05T15:59:37]         created by qcDocu v1.1.2, a tqs tool