Van der Bliek IR photometric standards
See van der Bliek et al. 1996, A&AS, 119, 547.
| Name |
RA(J2000) |
DEC(J2000) |
SpT |
J |
Err J |
H |
Err H |
K |
Err K |
L |
Err L |
L' |
Err L' |
M |
Err M |
| HR0088 |
00 22 50 |
-12 12 37 |
G3V |
5.302 |
0.011 |
4.970 |
0.006 |
4.913 |
0.006 |
4.896 |
0.021 |
|
|
4.976 |
0.008 |
| HR0721 |
02 26 59 |
-47 42 14 |
B5IV |
4.518 |
0.011 |
4.556 |
0.006 |
4.605 |
0.009 |
4.650 |
0.016 |
|
|
4.612 |
0.030 |
| HR2290 |
06 20 05 |
-48 44 15 |
G3V |
5.520 |
0.015 |
5.189 |
0.013 |
5.141 |
0.012 |
5.123 |
0.010 |
|
|
5.118 |
0.060 |
| HR2354 |
06 24 26 |
-63 25 39 |
G3III-IV |
5.375 |
0.022 |
5.053 |
0.012 |
5.004 |
0.010 |
4.989 |
0.020 |
|
|
5.003 |
0.017 |
| HR2318 |
06 24 45 |
-28 46 42 |
G2IV |
5.284 |
0.029 |
4.971 |
0.013 |
4.923 |
0.008 |
4.908 |
0.015 |
|
|
4.850 |
0.056 |
| HR2668 |
07 03 59 |
-43 37 01 |
K0V |
5.507 |
0.017 |
5.078 |
0.008 |
5.018 |
0.013 |
4.974 |
0.008 |
|
|
5.068 |
0.049 |
| HR2882 |
07 30 43 |
-37 20 25 |
G4V |
5.562 |
0.023 |
5.224 |
0.011 |
5.170 |
0.017 |
5.146 |
0.025 |
|
|
5.137 |
0.063 |
| HR5249 |
13 58 41 |
-44 48 11 |
B2IV-V |
4.342 |
0.010 |
4.430 |
0.012 |
4.507 |
0.010 |
4.575 |
0.014 |
|
|
4.534 |
0.032 |
| HR5384 |
14 23 14 |
+01 14 54 |
G1V |
5.126 |
0.012 |
4.749 |
0.009 |
4.703 |
0.006 |
4.571 |
0.023 |
|
|
4.597 |
0.014 |
| HR6070 |
16 18 18 |
-28 36 46 |
A0V |
4.831 |
0.005 |
4.799 |
0.016 |
4.813 |
0.006 |
4.807 |
0.006 |
|
|
4.717 |
0.077 |
| HR6736 |
18 03 52 |
-24 21 38 |
O8Iab: |
5.817 |
0.012 |
5.773 |
0.012 |
5.796 |
0.007 |
5.819 |
0.017 |
|
|
5.802 |
0.054 |
| HR7446 |
19 36 53 |
-07 01 39 |
B0.5III |
4.991 |
0.010 |
5.000 |
0.012 |
5.028 |
0.010 |
5.055 |
0.010 |
|
|
4.996 |
0.040 |
| HR7773 |
20 20 40 |
-12 45 32 |
B9IV |
4.842 |
0.015 |
4.846 |
0.011 |
4.859 |
0.010 |
4.893 |
0.006 |
|
|
4.887 |
0.040 |
| HR8042 |
21 02 12 |
-43 00 02 |
G3IV+ |
5.511 |
0.012 |
5.141 |
0.010 |
5.085 |
0.007 |
5.053 |
0.008 |
|
|
5.066 |
0.014 |
| HR8477 |
22 14 36 |
-41 22 15 |
G5V |
5.100 |
0.014 |
4.743 |
0.013 |
4.695 |
0.012 |
4.683 |
0.006 |
|
|
4.678 |
0.010 |
| HR8700 |
22 53 37 |
-48 35 50 |
G0V |
5.013 |
0.011 |
4.699 |
0.009 |
4.657 |
0.009 |
4.636 |
0.013 |
|
|
4.638 |
0.012 |
| HR8701 |
22 54 40 |
-70 04 30 |
G2.5IV |
4.973 |
0.017 |
4.641 |
0.007 |
4.591 |
0.005 |
4.566 |
0.009 |
|
|
4.550 |
0.019 |
| HR9076 |
23 59 55 |
-65 34 37 |
B9IV |
4.616 |
0.007 |
4.623 |
0.006 |
4.642 |
0.005 |
4.636 |
0.005 |
|
|
4.660 |
0.043 |
UKIRT IR photometric standards
| Name |
RA(J2000) |
DEC(J2000) |
SpT |
J |
Err J |
H |
Err H |
K |
Err K |
L |
Err L |
L' |
Err L' |
M |
Err M |
| BS 1140 |
03 44 48.215 |
+24 17 22.09 |
B7IV |
5.520 |
|
5.500 |
|
5.510 |
|
5.60 |
|
5.64 |
|
5.64 |
|
| HD 40335 |
05 58 13.523 |
+01 51 23.00 |
A0 |
6.555 |
|
6.473 |
|
6.452 |
|
6.43 |
|
6.43 |
|
6.41 |
|
| HD 77281 |
09 01 38.010 |
-01 28 34.76 |
A2 |
7.111 |
|
7.052 |
|
7.031 |
|
7.00 |
|
7.06 |
|
6.97 |
|
| HD106965 |
12 17 57.543 |
+01 34 31.14 |
A2 |
7.380 |
|
7.337 |
|
7.316 |
|
7.30 |
|
7.34 |
|
7.30 |
|
| HD161903 |
17 48 19.224 |
-01 48 29.72 |
A2 |
7.172 |
|
7.059 |
|
7.023 |
|
6.99 |
|
7.01 |
|
7.14 |
|
| GL 811.1 |
20 56 46.605 |
-10 26 54.61 |
dM4 |
7.832 |
|
7.185 |
|
6.946 |
|
6.70 |
|
6.69 |
|
6.68 |
|