On October 9, 2005 CONICA images have been taken with the pinhole array & different filters with and without neutral density. These data can be retrieved from here. They are meant to help estimating the astrometric shift existing between the different filters.
Table of data taken
All data have been taken with the S27 camera.Detailled list of settings here
The following provides the centroid position for 5 selected holes for each filter measured, as well as the corresponding light intensity.With the exception of the data taken with different lamp settings (seeabove table) for J, H, Ks, all data have been taken with a constant lamp setting aiming at getting an idea of the 'spectral effect' of the neutral density. For this purpose, frames with the same settings but with the lamp off have been taken (to remove the thermal effect related to the filter and not to the lamp).
'Pinhole_H_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
X
Y
FLUX
254.397
799.133
5925.50
511.720
547.032
5974.40
767.955
294.894
5512.50
763.619
803.765
5743.50
259.169
290.161
6454.70
'Pinhole_H_Full_S27.fits'
Different lamp settings DET DIT = 1.0000000 DET.NDIT = 5
X
Y
FLUX
254.330
799.152
1191.00
511.651
547.049
1176.80
767.885
294.914
1085.40
763.537
803.776
1124.80
259.107
290.182
1293.80
'Pinhole_H_NDS2_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 2
X
Y
FLUX
254.934
799.116
1134.00
511.725
547.021
1136.50
767.955
294.900
1059.00
763.634
803.225
1093.50
259.717
290.166
1226.00
'Pinhole_H_NDS_S27.fits'
Different lamp settings DET DIT = 60.0000000 DET.NDIT = 1
X
Y
FLUX
254.345
799.151
883.000
511.651
547.052
886.000
767.907
294.397
820.000
763.025
803.258
857.000
259.646
290.737
960.000
'Pinhole_J_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
X
Y
FLUX
259.162
808.013
1806.50
516.177
555.150
1876.30
773.716
302.261
1739.10
768.847
812.102
1772.70
263.963
298.078
2066.80
'Pinhole_J_Full_S27.fits'
Different lamp settings DET DIT = 10.0000000 DET.NDIT = 1
X
Y
FLUX
259.131
808.014
1545.00
516.136
555.161
1634.00
773.113
302.285
1482.00
768.239
812.101
1508.00
263.932
298.104
1766.00
'Pinhole_J_NDS2_S27.fits'
DET DIT = 10.0000000 DET.NDIT = 1
X
Y
FLUX
259.715
808.010
716.000
516.186
555.133
758.000
773.722
302.278
693.000
768.864
812.082
716.000
263.949
297.576
825.000
'Pinhole_J_NDS_S27.fits'
Different lamp settings DET DIT = 120.0000000 DET.NDIT = 1
X
Y
FLUX
259.717
808.049
271.000
516.177
555.785
276.000
773.637
302.306
274.000
769.251
812.155
264.000
263.974
298.059
311.000
'Pinhole_K_Full2_S27.fits'
DET DIT = 0.3500000 DET.NDIT = 10
X
Y
FLUX
254.198
799.063
7131.00
510.340
547.061
7096.50
766.967
295.030
6377.10
762.126
803.700
6728.20
258.979
290.291
7447.90
'Pinhole_K_Full_S27.fits'
Different lamp settings DET DIT = 1.0000000 DET.NDIT = 5
X
Y
FLUX
254.129
799.089
2198.60
510.257
547.085
2196.20
766.362
295.058
1959.80
762.050
803.721
2060.80
258.910
290.325
2285.80
'Pinhole_K_NDS2_S27.fits'
DET DIT = 5.0000000 DET.NDIT = 2
X
Y
FLUX
254.200
799.058
1230.00
510.346
547.049
1220.00
766.973
295.029
1095.50
762.136
803.699
1152.50
258.983
290.292
1290.50
'Pinhole_K_NDS_S27.fits'