WFI Dismounting Procedures
In the control room:
- Open an xterm on w2p2ins, and type rlogin odt5 -l fcdrun
- Now type su - vltmgr.
- Now bring down the FIERA environments by typing vccEnvStop -e wodt5.
- In the computer room, set the Toggle Switch to Analog.
- If FEROS adapter is in, Park M3.
- Main Drives OFF, Amplifiers ON.
In the dome:
- Put the telescope lock pins in (Alpha & Delta).
- Switch off the WFI controller.
- Switch off the FIERA unit.
- Switch off the PULPO unit.
- At the PULPO, disconnect cables labelled:
- Pulpo power cable
- Pulpo
- Telephone alarm (plug in the attached bypass)
- The two black optic fibers
- At the FIERA junction box (base of telescope, west side) disconnect the two arange optic fibres.
- Disconnect the N2 hose flow.
- Disconnect Adapter.
- At the WFI controller, disconnect:
- RS-232
- PULPO / SHUTTER
- X-114
- X-115
- At the FIERA rack, disconnect:
- Big black cable
- DO NOT FORGET TO DISCONNECT The Pump (at the telescope base).
- The 2 cooling hoses shielded male and female and connect one to each other
- The ground cable
- Phone mechanics, they will now dismount the WFI using the special tools kept in the big green tool box next to the electronic rack at the 2.2m dome floor.