mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
VIMOS:
IFU efficiency
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
VIMOS trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2018-04-04T03:38:12 (UT)
  | now: 2024-11-23T07:03:15 (UT) muc03 QC pipeline: vimos-2.9.19 (installed 2016-03-17)
same group: LR_blue LR_red MR HR_blue HR_orange HR_red
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
VIMOS news:  
Report news:
DATE*: [?] 2018-03-28
no data | NLT
2018-03-29
no data | NLT
2018-03-30
no data | NLT
2018-03-31
no data | NLT
2018-04-01
no data | NLT
2018-04-02
no data | NLT
2018-04-03
no data | NLT
r...
Raw CAL displays:
no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files
P...
CAL product quality:
no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.0555 none VAL0.04,0.09 1 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 1:1
1 QC1DB none   none none  0 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 2:1
2 QC1DB MEDIAN 0.0792 none VAL0.04,0.09 1 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 1:1
2 QC1DB none   none none  0 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 2:1
3 QC1DB MEDIAN 0.053 none VAL0.04,0.09 1 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 1:1
3 QC1DB none   none none  0 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 2:1
4 QC1DB MEDIAN 0.0577 none VAL0.04,0.09 1 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 1:1
4 QC1DB none   none none  0 efficiency7 this | last_yr | all efficiency at 6100A, IFU mag 2:1
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:
(numbers below apply to this dataset)
efficiency7
median:0.0555none
fixed thresholds:0.04...0.09none
N_data plotted:1
[click plot for closeup]
Plot 2
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:
(numbers below apply to this dataset)
efficiency7
median:0.0792none
fixed thresholds:0.04...0.09none
N_data plotted:1
[click plot for closeup]
Plot 3
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:
(numbers below apply to this dataset)
efficiency7
median:0.053none
fixed thresholds:0.04...0.09none
N_data plotted:1
[click plot for closeup]
Plot 4
scores: 1|
data source:vimos_ifu_std
(QC1 database)
dataset:
(numbers below apply to this dataset)
efficiency7
median:0.0577none
fixed thresholds:0.04...0.09none
N_data plotted:1
[click plot for closeup]
This plot

Trending plot for the overall IFU efficiency, measured using spectrophotometric standard stars.

The following settings are used:
LR_blue grism + OS-blue filter
LR_red grism + OS-red filter
MR grism + GG475 filter
HR_blue grism (without filter)
HR_orange grism + GG435 filter
HR_red grism + GG475 filter

For the MR and HR grisms, both IFU magnification configurations (1:1, 2:1) are plotted but only 1:1 is scored.

The thresholds for scoring are set for monitoring the quality of the individual calibration. Outliers could indicate that the measurement was done through (thin) clouds or that background subtraction could not be done properly due to high sky brightness in early twilight. Such measurements should be repeated.

Template ID: ifu_cal_Specphot. Pipeline recipe: vmifustandard.

Plots that show the efficiency vs. wavelength have been created by averaging several standard star measurements. They show the efficiency before and after the 2010 instrument upgrade. Measurements with the new HR_blue grism after April 2012 are included here.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up