Plot ? |
Symb ? |
Source * |
Average ? |
Thresholds ? |
N_ data |
QC1 parameter |
Data downloads |
Remarks |
method |
value |
unit |
method |
value |
1 |
| QC1DB |
MEDIAN |
202 |
none |
VAL | 180,220 |
13 |
resol2 |
this |
last_yr |
all
|
spectral resolution, centre |
2 |
| QC1DB |
MEDIAN |
202 |
none |
VAL | 180,220 |
11 |
resol2 |
this |
last_yr |
all
|
spectral resolution, centre |
3 |
| QC1DB |
MEDIAN |
203 |
none |
VAL | 180,220 |
13 |
resol2 |
this |
last_yr |
all
|
spectral resolution, centre |
4 |
| QC1DB |
MEDIAN |
203 |
none |
VAL | 180,220 |
13 |
resol2 |
this |
last_yr |
all
|
spectral resolution, centre |
|
*Data sources: QC1DB: QC1 database; LOCAL: local data source
|
Plot 1 scores: 5|
| data source: | vimos_mos_wave (QC1 database) |
dataset: | resol2 | |
median: | 202 | none |
fixed thresholds: | 180...220 | none |
N_data plotted: | 13 |
[click plot for closeup] |
Plot 2 scores: 5|
| data source: | vimos_mos_wave (QC1 database) |
dataset: | resol2 | |
median: | 202 | none |
fixed thresholds: | 180...220 | none |
N_data plotted: | 11 |
[click plot for closeup] |
Plot 3 scores: 5|
| data source: | vimos_mos_wave (QC1 database) |
dataset: | resol2 | |
median: | 203 | none |
fixed thresholds: | 180...220 | none |
N_data plotted: | 13 |
[click plot for closeup] |
Plot 4 scores: 5|
| data source: | vimos_mos_wave (QC1 database) |
dataset: | resol2 | |
median: | 203 | none |
fixed thresholds: | 180...220 | none |
N_data plotted: | 13 |
[click plot for closeup] |
This plot
Trending plot for resolution (resolving power R) derived from MOS arc lamp measurements.
Only arc lamp measurements taken to calibrate MOS science observations are
used; exposures with the standard star masks are disregarded. Only
measurements with slit_width_dis=1.0 are plotted.
Resolution is measured at the blue and the red end, and at the centre of the
spectral range. The "cent" plots only show the latter; they include scoring.
The "full" plots also show the results at the blue and red ends; these are not
scored.
For LR_blue, the resolution at the blue and red ends is usually not
well determined; therefore only the central value is
plotted.
For MR, there is a similar issue at the blue end for masks with multiplexing:
spectra from slits which are at the same x position can overlap and
the pipeline then reports R=0 for the resolving power at the blue end.
Template ID: mos_cal_Arc (daytime), mos_cal_NightCalib (attached
night-time). Pipeline recipe: vmspcaldisp.
General information
Click on any of the plots to see a close-up version.
The latest date is indicated on top of the plot.
If configured,
- data points belonging to the latest date are specially marked
- statistical averages are indicated by a solid line, and thresholds by broken lines
- outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
- "aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓)
- you can download the data for each parameter set if the 'Data downloads' link shows up
|