mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
QC links:
CAL
VIRCAM calChecker: calibration completeness monitor (CAL4CAL)
Last update: 2023-06-12T09:49:33 (UT)
[?]
  Paranal date*: 2023-06-11         muc07 [?]   server: www.eso.org HQ
HELP ASSOC-RULES DETAILS
Last header: VCAM. 2023-06-01T10:36:30.768.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
LINEARITY9 9.8REMINDER: take as soon as possible
GAIN9 9.8REMINDER: take as soon as possible
DARKCURRENT9 13.1REMINDER: take as soon as possible!
DOME9 9.8REMINDER: take as soon as possible
VIRCAM news: End of operations on 2023-03-06

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
old issue
2023-05-31

report | NLT
2023-06-05

no data | NLT
2023-06-06

no data | NLT
2023-06-07

no data | NLT
2023-06-08

no data | NLT
2023-06-09

no data | NLT
2023-06-10

no data | NLT
2023-06-11

no data | NLT
LOST?
[not applicable
for 'cal4cal']
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files      
P...
CAL product quality:     [?]
products no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products      
Data types: Setup:        
STD H_6_5 miss
[not yet analyzed]
                DARK | TWIL H_6_5
J_6_5 miss
[not yet analyzed]
                DARK | TWIL J_6_5
Ks_6_5 miss
[not yet analyzed]
                DARK | TWIL Ks_6_5
Y_6_5 miss
[not yet analyzed]
                DARK | TWIL Y_6_5
Z_6_5 miss
[not yet analyzed]
                DARK | TWIL Z_6_5
 
INFORMATION SPECIFIC TO VIRCAM           [?]

The setup coding for twilight flat calibration frames is INS.FILT1.NAME_DET.NDIT_DET.DIT
The calChecker checks that there is a dark matching in NDIT and DIT available for twilight flat frames.

The setup coding for photometric standard star calibration frames is INS.FILT1.NAME_DET.NDIT_DET.DIT
The calChecker checks that there is a twilight flat matching in filter and a dark matching in NDIT and DIT available for standard star frames:
CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 21
Range of days for the calibration memory (issue memory plus longest validity): 29
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   increm