mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
CRIRES
QC links:
CAL
CRIRES calChecker: calibration completeness monitor
Last update: 2024-11-21T11:12:32 (UT)
[?]
  Paranal date*: 2024-11-20         muc03 [?]   server: www.eso.org HQ
HELP ASSOC-RULES DETAILS
Last header: CRIRE. 2024-11-21T10:58:55.373.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
RV_MONITORING7 29.5REMINDER: take as soon as possible!
DeepFlat_H45 39.9soft REMINDER: next 18 day(s)
DeepFlat_K45 39.8soft REMINDER: next 18 day(s)
DeepFlat_L90 84.8soft REMINDER: next 32 day(s)
DeepFlat_M90 81.7soft REMINDER: next 35 day(s)
CRIRES news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   [daytime calibrations ongoing, started 08:50UT]
DATE*:   [?]
[color if science data acquired]
2024-11-14

report | NLT
2024-11-15

report | NLT
2024-11-16
SM
24
report | NLT
2024-11-17

report | NLT
2024-11-18

report | NLT
2024-11-19
10
report | NLT
2024-11-20
SM
124
report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw raw      
P...
CAL product quality:     [?]
products products products products products products products      
Data types: Setup:        
SCI_2D Y1029_w_0.2  
 
 
 
 
 
nok
[daycals ongoing]
  FLAT | WAVE Y1029_w_0.2
SCI_NOD K2166_w_0.2  
 
ok
 
 
 
ok
  all ok  
L3412_w_0.4  
 
 
 
 
 
miss
[daycals ongoing]
  FLAT | WAVE L3412_w_0.4
M4368_w_0.2  
 
 
 
 
 
ok
  all ok  
SCI_DIRECT K2192_w_0.2  
 
 
 
 
ok
 
  all ok  
L3244_w_0.2  
 
 
 
 
ok
 
  all ok  
L3262_w_0.2  
 
 
 
 
ok
 
  all ok  
L3302_w_0.2  
 
 
 
 
ok
 
  all ok  
L3340_w_0.2  
 
 
 
 
ok
 
  all ok  
L3377_w_0.2  
 
 
 
 
ok
 
  all ok  
L3412_w_0.2  
 
 
 
 
ok
 
  all ok  
L3426_w_0.2  
 
 
 
 
ok
 
  all ok  
L3426_w_0.4  
 
 
 
 
ok
 
  all ok  
M4187_w_0.2  
 
 
 
 
 
miss
[daycals ongoing]
  DARK | FLAT | WAVE M4187_w_0.2
M4211_w_0.2  
 
 
 
 
 
ok
  all ok  
M4266_w_0.2  
 
 
 
 
 
ok
  all ok  
M4318_w_0.2  
 
 
 
 
 
ok
  all ok  
M4368_w_0.2  
 
 
 
 
 
ok
  all ok  
M4416_w_0.2  
 
 
 
 
 
ok
  all ok  
M4461_w_0.2  
 
 
 
 
 
ok
  all ok  
M4504_w_0.2  
 
 
 
 
 
ok
  all ok  
 
INFORMATION SPECIFIC TO CRIRES           [?]
The following keys are used to define a SCIENCE CRIRES setup:

DET.SEQ1.DIT DIT used
DET.NDIT NDIT used
INS.WLEN.ID
INS.SLIT1.ID slit width

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 7
Range of days for the calibration memory (issue memory plus longest validity): 14
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   increm