FORS2 trending system: SCORES (quick-look)
HELP USERS-GUIDE MORE
Last update: 2024-12-22T11:18:37 (UT)
  | now: 2024-12-22T11:42:08 (UT) muc01 QC pipeline: fors-5.6.10 (installed 2024-04-19)
same group: SCR_FF_RI SCR_FF_uv SCR_FF_b   SCR_FF_RMS_RI SCR_FF_RMS_uv SCR_FF_RMS_b
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
FORS2 news:  
Report news:
DATE*: [?] 2024-12-15
no data | NLT
2024-12-16
no data | NLT
2024-12-17
no data | NLT
2024-12-18
no data | NLT
2024-12-19
no data | NLT
2024-12-20
no data | NLT
2024-12-21
no data | NLT
r...
Raw CAL displays:
no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files no CAL raw files
P...
CAL product quality:
no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products no CAL products
 
transfer   ngas [?]

HC plot | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
flux of imaging flat-field lamps (scores, last 7 days up to 2024-12-11*)
1: Chip1_b_low_gain
2|
2: Chip2_b_low_gain
2|
3: Chip1_b_high_gain
2|
4: Chip2_b_high_gain
2|
Quality comments (certified nights only):
Plot Date* AB name (linked to score report) score product quality comment
Plot 22024-12-07FORS2.2024-12-08T08:47:53.665_tpl.ab
conad slightly below the threshold.
"Date" links to complete AB product page; "AB" links to score report


Scores

This is the quick-look version of the HealthCheck (HC) Monitor. It displays scores for each HC report. Scores are flags assessing the compliance of data points with configured thresholds. A green score indicates that the corresponding instrument component is performing as expected (OK) in the monitored time range. A red score is the result of a parameter exceeding these thresholds, and may indicate a problem.

Scoring has both an automatic and an interactive component. The automatic part consists of monitoring, pipeline-processing, and flagging new data once per hour, 24/7. The interactive component is the certification step which is performed by the QC scientist. It involves the analysis of red scores: A confirmation of their validity, an assessment of the severity of the red score and its cause, and often an analysis comment in the AB monitor. In cases of serious instrument issues, feedback to Paranal operations and/or USD is given. However, this analysis step cannot be guaranteed to be available at the same time as the automatic scoring. Do not expect new analysis results during weekends, holidays or other off-duty times.

The last score, per plot, will determine the current plot score, which is displayed as a larger symbol. The other, older plot scores display only the recent history of instrument scores. As part of the automatic scoring, a red score will be automatically overwritten by any new data that produce a green score. The date of any score can be seen by mousing over its score symbol. As part of the interactive analysis, there is also the possibility for the QC scientist to manually adjust thresholds and turn a red score into a green one, or to delete a false red score. Often this occurs after interaction with Paranal staff, after discussing the significance of the alert score. Use the 'contact' link to get in touch.

If available, a table with quality comments is displayed on the scores&comments page, usually offering additional information about data with red scores. A comment may refer to the quality of the pipeline products and not necessarily to the exact parameter scored in this report. Quality comments are entered by the QC scientist as part of the analysis workflow.

Scores are based on the QC data for the last 7 days before the indicated date. This date is always the last date with data for this report.

The 'Quality comments' are collected from the QC scientist certification review and are available for certified nights.

Information on demand:
- scroll over the small symbols and see the individual dates of the underlying data.
- click on them and see the detailed score report for that particular data set.