VIRCAM: Calibration data
RAW CALIBRATION DATA | MASTER CALIBRATION DATA | Calibration cascade | Static calibration files

RAW CALIBRATION DATA

Calibration data for VIRCAM are taken for two purposes:

  • assess the instrument status
  • reduce science data

Generally, VIRCAM calibration data are taken as daytime calibrations.

The calibration data taken are processed by QC Garching to obtain calibration solutions. These solutions come as:

  • calibration product FITS file frames (e.g. master DARK or master twilight flat frames)
  • calibration product FITS tables (e.g. linearity correction table, gain table)
The following list shows the raw calibration data together with their important fits header keys:

Frame Type DPR.TYPE Purpose
RESET BIAS monitor the Uncorr read mode (reset-read)
DOME FLAT FLAT,LAMP monitor flat field cosmetics
DARK CURRENT DARK,CURRENT monitor dark current ( ADU/sec )
LINEARITY FLAT,LAMP,LINEARITY
DARK,LINEARITY
FLAT,LAMP,CHECK
DARK,CHECK
calibrate the detector non-linearity, retrieve bad pixel
GAIN FLAT,LAMP,GAIN
DARK,GAIN
extract detector gain
DARK DARK calibrate the dark level and , hot pixel
TWILIGHT FLAT FLAT,TWILIGHT calibrate fixed pattern noise
STD STD,FLUX monior the instrumental throughput


MASTER CALIBRATION DATA
RAW CALIBRATION DATA | MASTER CALIBRATION DATA | Calibration cascade | Static calibration files

Among others, the following types of master calibration data are produced using the vircam data reduction pipeline. Only those calibrations are listed, which are certified and ingested into the archive:

Frame Type recipe Description product code N
MASTER_BIAS vircam_reset_combine master bias frame VC_MRST 5
MASTER_DOME_FLAT vircam_dome_flat_combine master dome flat VC_MDOF 5
MASTER_DARK_CURRENT vircam_dark_current retrieve dark current VC_MDCT 14
MASTER_CHANNEL_TABLE
MASTER_BPM
vircam_linearity_analyse non-linearity correction VC_MCHT
VC_MBPM
79
MASTER_READGAIN_TABLE vircam_detector_noise detector gain VC_PRGT 4
MASTER_DARK vircam_dark_combine dark level, hot pixel VC_MDRK 5
MASTER_TWILIGHT_FLAT
MASTER_CONF
vircam_twilight_flat_combine flat fielding VC_MTWF
VC_PCFM
20
JITTERED_IMAGE_STD
OBJECT_CATALOGUE_STD
CONFIDENCE_MAP_STD
ILLCORR_TAB_STD
vircam_standard_process photometric zeropoint VC_PJTI
VC_POJC
VC_PCFM
5


Calibration cascade
RAW CALIBRATION DATA | MASTER CALIBRATION DATA | Calibration cascade | Static calibration files

Like for nearly all astronomical data, the reduction of VIRCAM calibration frames requires a cascading scheme where the mutual dependencies of products and raw frames have to be respected. The MASTER_CHANNEL_TABLE can be produced from raw files only, but all the other products require the prior generation of other calibration products. The proper sequence of all these production steps is called the calibration cascade.


Static calibration files
RAW CALIBRATION DATA | MASTER CALIBRATION DATA | Calibration cascade | Static calibration files

Static calibration tables (the ones not being regularly processed from raw calibration data) come as FITS tables and are available through the calSelector archive service.

product name PRO.CATG Purpose
VC_GCTI_<yymmdd>A_Z.fits CHANNEL_TABLE_INIT detector register definition, initial gains
VC_GMMC_<yymmdd>A.fits MASTER_2MASS_CATALOGUE root file of the 2MASS photometric and astrometric catalogue
VC_GPCT_<yymmdd>A.fits PHOTCAL_TAB color coefficients, color terms
VC_GCSN_<yymmdd>A.fits SCHLEGEL_MAP_NORTH interstellar extinction map
VC_GCSS_<yymmdd>A.fits SCHLEGEL_MAP_SOUTH interstellar extinction map