SPHERE trending system: HEALTH CHECK report
Last update: 2024-11-21T05:16:59 (UT)
[enable javascript for displaying time difference!]
General news:
NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
SPHERE news:
Note that the current Health Check monitor runs with an incomplete pipeline and an incomplete set of QC1 parameters.
QCG can currently not guarantee completeness and significance at the usual level.
Report news:
Plot?
Symb?
Source *
Average ?
Thresholds ?
N_ data
QC1 parameter
Data downloads
Remarks
method
value
unit
method
value
1
QC1DB
MEDIAN
0.888255
efficiency
VAL 0.6,1.0
23
qc_med
this |
last_yr |
all
readmode = SlowPolarimetry, CAM=1
2
QC1DB
MEDIAN
0.77481
efficiency
VAL 0.6,1.0
23
qc_med
this |
last_yr |
all
readmode = SlowPolarimetry, CAM=2
3
QC1DB
MEDIAN
0.795269
efficiency
VAL 0.6,1.0
20
qc_med
this |
last_yr |
all
readmode = FastPolarimetry, CAM=1
4
QC1DB
MEDIAN
0.697755
efficiency
VAL 0.6,1.0
20
qc_med
this |
last_yr |
all
readmode = FastPolarimetry, CAM=2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1 scores: 3 |
data source: sphere_zimpol_modem_eff (QC1 database)
dataset: qc_med
median: 0.888255 efficiency
fixed thresholds: 0.6...1.0 efficiency
N_data plotted: 23
[click plot for closeup]
Plot 2 scores: 3 |
data source: sphere_zimpol_modem_eff (QC1 database)
dataset: qc_med
median: 0.77481 efficiency
fixed thresholds: 0.6...1.0 efficiency
N_data plotted: 23
[click plot for closeup]
Plot 3 scores: 3 |
data source: sphere_zimpol_modem_eff (QC1 database)
dataset: qc_med
median: 0.795269 efficiency
fixed thresholds: 0.6...1.0 efficiency
N_data plotted: 20
[click plot for closeup]
Plot 4 scores: 3 |
data source: sphere_zimpol_modem_eff (QC1 database)
dataset: qc_med
median: 0.697755 efficiency
fixed thresholds: 0.6...1.0 efficiency
N_data plotted: 20
[click plot for closeup]
This plot
The four boxes show the polarimetric phase modulation demodulation efficiency as calculated
by the pipeline recipe for
both detectors (CAM1 and CAM2) and
both readmodes (S= SlowPolarimetry and F=FastPolarimetry).
General information
Click on any of the plots to see a close-up version .
The latest date is indicated on top of the plot.
If configured,
data points belonging to the latest date are specially marked
statistical averages are indicated by a solid line, and thresholds by broken lines
outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
"aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓ )
you can download the data for each parameter set if the 'Data downloads' link shows up