[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
PIONIER trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T22:25:11 (UT)
  | now: 2024-11-21T23:01:53 (UT) muc05 QC pipeline: pioni-3.9.6 (installed 2023-06-22)
close window history: 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.00482 NONE none  15452 dark_med all (full time range) GRISM High sensitivity (polar.voltage 7100)
2 QC1DB MEDIAN 0.00478 NONE none  2742 dark_med all (full time range) GRISM Medium sensitivity (polar.voltage 5000)
3 QC1DB MEDIAN 0.00661 NONE none  619 dark_med all (full time range) GRISM Low sensitivity (polar.voltage 3000)
4 QC1DB MEDIAN 0.0012 NONE none  3366 dark_med all (full time range) GRISM+WOL High sensitivity (polar.voltage 7100)
5 QC1DB MEDIAN 0.00164 NONE none  908 dark_med all (full time range) FREE High sensitivity (polar.voltage 7100)
6 QC1DB MEDIAN -0.0192 NONE none  2842 dark_med all (full time range) FREE Medium sensitivity (polar.voltage 5000)
7 QC1DB MEDIAN -0.00532 NONE none  3 dark_med all (full time range) FREE Low sensitivity (polar.voltage 3000)
8 QC1DB MEDIAN   NONE none  0 dark_med all (full time range) FREE Low sensitivity (polar.voltage 1000)
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:0.00482NONE
thresholds:none 
N_data plotted:15452
[click plot for closeup]
Plot 2
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:0.00478NONE
thresholds:none 
N_data plotted:2742
[click plot for closeup]
Plot 3
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:0.00661NONE
thresholds:none 
N_data plotted:619
[click plot for closeup]
Plot 4
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:0.0012NONE
thresholds:none 
N_data plotted:3366
[click plot for closeup]
Plot 5
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:0.00164NONE
thresholds:none 
N_data plotted:908
[click plot for closeup]
Plot 6
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:-0.0192NONE
thresholds:none 
N_data plotted:2842
[click plot for closeup]
Plot 7
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:-0.00532NONE
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 8
scores: not implemented
data source:pionier_dark
(QC1 database)
dataset:dark_med
median:no dataNONE
thresholds:none 
N_data plotted:0
[click plot for closeup]
This plot

DARKs are taken once a day as day-time calibrations as well as at night within each OB.
The DARK taken within the night OB needs also to be monitor to ensure accurate calibration of the photometry.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up