mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
ESPRESSO:
wavecal: ThAr lines
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
ESPRESSO trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T19:00:52 (UT)
  | now: 2024-11-21T19:27:25 (UT) muc11 QC pipeline: espdr-2.5.0 (installed 2022-06-28)
same group: ThAr_HR_1x1 ThAr_HR_2x1 ThAr_HR_4x2 ThAr_UHR_1x1 ThAr_MR_4x2 ThAr_MR_8x4
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
ESPRESSO news:  
Report news:
DATE*: [?] 2024-11-14
report | NLT
2024-11-15
report | NLT
2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 1.11e+03 NONE VAL1050,1150 184 fiba_thar_lines_tot this | last_yr | all total number of ThAr lines, fibre A
2 QC1DB MEDIAN 1.02 NONE VAL0.4,1.6 184 fiba_thar_flux_ratio this | last_yr | all median flux ratio of ThAr lines to reference line table, fibre A
3 QC1DB MEDIAN 1.12e+03 NONE VAL1050,1150 184 fibb_thar_lines_tot this | last_yr | all total number of ThAr lines, fibre B
4 QC1DB MEDIAN 1.49 NONE VAL0.4,1.6 184 fibb_thar_flux_ratio this | last_yr | all median flux ratio of ThAr lines to reference line table, fibre B
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 14|
data source:espresso_wave_thar_a
(QC1 database)
dataset:fiba_thar_lines_tot
median:1.11e+03NONE
fixed thresholds:1050...1150NONE
N_data plotted:184
[click plot for closeup]
Plot 2
scores: 14|
data source:espresso_wave_thar_a
(QC1 database)
dataset:fiba_thar_flux_ratio
median:1.02NONE
fixed thresholds:0.4...1.6NONE
N_data plotted:184
[click plot for closeup]
Plot 3
scores: 14|
data source:espresso_wave_thar_b
(QC1 database)
dataset:fibb_thar_lines_tot
median:1.12e+03NONE
fixed thresholds:1050...1150NONE
N_data plotted:184
[click plot for closeup]
Plot 4
scores: 14|
data source:espresso_wave_thar_b
(QC1 database)
dataset:fibb_thar_flux_ratio
median:1.49NONE
fixed thresholds:0.4...1.6NONE
N_data plotted:184
[click plot for closeup]
This plot

Trending plots for ThAr wavelength-calibration exposures.

The plots show the total number of ThAr lines that are used for the wavelength calibrations and the median flux ratio of these lines with respect to a reference line table.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up