Plot ? |
Symb ? |
Source * |
Average ? |
Thresholds ? |
N_ data |
QC1 parameter |
Data downloads |
Remarks |
method |
value |
unit |
method |
value |
1 |
| QC1DB |
MEDIAN |
45.3 |
ADU |
VAL | 1,50 |
31 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, average over all 16 detectors |
2 |
| QC1DB |
MEDIAN |
35.8 |
ADU |
VAL | 1,130 |
496 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, values of all detetcors |
2 |
| QC1DB |
none |
|
ADU |
none | |
31 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, values of detector 2 |
2 |
| QC1DB |
none |
|
ADU |
none | |
31 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, values of detector 3 |
2 |
| QC1DB |
none |
|
ADU |
none | |
31 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, values of detector 13 |
3 |
| QC1DB |
MEDIAN |
39.6 |
ADU |
VAL | 0.1,50 |
31 |
qc_resetdiff_rms |
this |
last_yr |
all
|
RESETDIFFRMS, stdev over all detectors |
4 |
■ | LOCAL |
none |
|
ADU |
none | |
465 |
qc_resetdiff_rms |
n/a |
Score per Detector: Green = within the thresholds |
4 |
■ | LOCAL |
none |
|
ADU |
none | |
31 |
qc_resetdiff_rms |
n/a |
Score per Detector: Red = beyond thresholds |
|
*Data sources: QC1DB: QC1 database; LOCAL: local data source
|
Plot 1 scores: 3|
| data source: | vircam_reset (QC1 database) |
dataset: | qc_resetdiff_rms | |
median: | 45.3 | ADU |
fixed thresholds: | 1...50 | ADU |
N_data plotted: | 31 |
[click plot for closeup] |
Plot 2 scores: not implemented
| data source: | vircam_reset (QC1 database) |
dataset: (numbers below apply to this dataset) | qc_resetdiff_rms | |
median: | 35.8 | ADU |
fixed thresholds: | 1...130 | ADU |
N_data plotted: | 496 |
[click plot for closeup] |
Plot 3 scores: 3|
| data source: | vircam_reset (QC1 database) |
dataset: | qc_resetdiff_rms | |
median: | 39.6 | ADU |
fixed thresholds: | 0.1...50 | ADU |
N_data plotted: | 31 |
[click plot for closeup] |
Plot 4 scores: not implemented
| data source: | local data source
|
dataset: (numbers below apply to this dataset) | qc_resetdiff_rms | ■ |
average: | none |
thresholds: | none |
N_data plotted: | 465 |
[click plot for closeup] |
This plot
Trending plot for RMS noise in MASTER_BIAS minus REFERENCE_BIAS combined product frame.
QC parameters is derived from each detector of daily RESET calibrations.
Name:
Fits header: QC.RESETDIFFRMS,
QC1 DB: qc_resetdiff_rms
Description:
RMS noise of master minus reference product frame
Setup:
DET.DIT = MINDIT = 1.0011 sec
These plots describe:
Fig. 1. Average view: The QC parameter averaged over all detectors.
This view is sensitive to common changes.
Fig. 2. Resolved View: The QC parameter resolved for all detectors.
Fig. 3. Scatter View: The standard deviation of the QC parameter, obtained from the sample of all detectors.
This view is sensitive changes of individual detectors.
Fig. 4. Scoring View: Scoring values of all 16 QC parameters.
Green = within the acceptance thresholds.
Red = beyond the acceptance thresholds.
Find more information on the VIRCAM RESET tutorial page.
General information
Click on any of the plots to see a close-up version.
The latest date is indicated on top of the plot.
If configured,
- data points belonging to the latest date are specially marked
- statistical averages are indicated by a solid line, and thresholds by broken lines
- outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
- "aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓)
- you can download the data for each parameter set if the 'Data downloads' link shows up
|