mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
PIONIER:
Instrument Efficiency
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
PIONIER trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T21:00:03 (UT)
  | now: 2024-11-21T22:24:36 (UT) muc05 QC pipeline: pioni-3.9.6 (installed 2023-06-22)
same group: VIS_GRISM FREE_MS GRIWOL   FLUX_GR FR_MS GRIWOL CP
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
PIONIER news: 2023-02-06 Internal efficiency, median darks are outside KPI which is related to a pump not working. As operations continue, the thresholds have been adapted to show calibratibility and keep track of sudden anomalies.
Report news:
DATE*: [?] 2024-11-14
report | NLT
2024-11-15
report | NLT
2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
no data | NLT
r...
Raw CAL displays:
n/a n/a n/a n/a n/a n/a n/a no CAL raw files
P...
CAL product quality:
products products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.456 NONE VAL0.055,1.1 106 vis12_avg this | last_yr | all VIS^2 High sensitivity Baseline12
2 QC1DB MEDIAN 0.657 NONE VAL0.2,1.1 106 vis13_avg this | last_yr | all Baseline13
3 QC1DB MEDIAN 0.533 NONE VAL0.2,1.1 106 vis14_avg this | last_yr | all Baseline14
4 QC1DB MEDIAN 0.376 NONE VAL0.055,1.1 106 vis23_avg this | last_yr | all Baseline23
5 QC1DB MEDIAN 0.287 NONE VAL0.055,1.1 106 vis24_avg this | last_yr | all Baseline24&
6 QC1DB MEDIAN 0.636 NONE VAL0.2,1.1 106 vis34_avg this | last_yr | all Baseline34&
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis12_avg
median:0.456NONE
fixed thresholds:0.055...1.1NONE
N_data plotted:106
[click plot for closeup]
Plot 2
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis13_avg
median:0.657NONE
fixed thresholds:0.2...1.1NONE
N_data plotted:106
[click plot for closeup]
Plot 3
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis14_avg
median:0.533NONE
fixed thresholds:0.2...1.1NONE
N_data plotted:106
[click plot for closeup]
Plot 4
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis23_avg
median:0.376NONE
fixed thresholds:0.055...1.1NONE
N_data plotted:106
[click plot for closeup]
Plot 5
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis24_avg
median:0.287NONE
fixed thresholds:0.055...1.1NONE
N_data plotted:106
[click plot for closeup]
Plot 6
scores: not implemented
data source:pionier_intern_fringe
(QC1 database)
dataset:vis34_avg
median:0.636NONE
fixed thresholds:0.2...1.1NONE
N_data plotted:106
[click plot for closeup]
This plot

The Instrumental Visibility and Flux measured on the internal lamp for the different dispersive elements (GRISM, FREE and GRIS+Wollaston). Only the settings with GRISM or FREE are offered for operations.

The Visibility (VIS_) is given for the 6 baselines and the flux (FLUX_) for the 4 PIONIER input beams.
The saturation limit is above 4000 ADUs.
The low Internal Visibility for the beam combinations including beam 2 is due to the source.
This plot should be looked at in correlation with the plots showing the fluxes of the different beams.

The detector polarization voltages (DET.POLAR) are :
High Sensitivity : 7100 mV
Medium_ Sensitivity: 5000 mV
Low_Sensitivity : 1000 mV  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up