[ ESO ]

UVES Scientific CCD System

HOME INDEX SEARCH HELP NEWS

The Blue Scientific CCD - "PAVAROTTI"

(see also   The Blue Scientific CCD "MARLENE"   before   the upgrade on 13/Oct/2004)

CCD Specification

CCD alias name : PAVAROTTI
Type : EEV CCD-44, backside illuminated, AR coated
Number of pixels : [H] 2048, [V] 4102
Number of outputs : 2
Pixel size : 15 x 15 microns

Cosmetic and Flat field images

Click here to see the   Flat field images.

Linearity

Minimum specification: 1 %
 
Peak to peak non linearity: 0.63 %

Click here to see the   graphics for the linearity.

Dark Current

Exposure time: 3.600 s
Readout mode: 50 kpix/s
Port: right
Minimum specification: 2 e-/pixel/hour
 
Dark current: < 0.1 ± 0.1 ADU/pixel/hour
  < 0.15 ± 0.15 e-/pixel/hour

Click here to see the   Bias and Dark images.

Charge Transfer Efficiency (CTE)

Method used: Fe55
Minimum specification: 0.999995
 
CTE serial (horizontal) left: 0.999993
CTE serial (horizontal) right: 0.999991
CTE parallel (vertical): 0.99999927

CTE measured at 50 kpix/s and the high gain amplification.

Full Well

Full well is more then 100.000 electrons.

Readout Direction

In dispersion direction.

Quantum Efficiency @ Temperature : -117 °C

Clock mode: 225 kHz/4 ports/low gain/512
Conversion factor: 3.1600 e-/ADU ± 0.02793 for 24726 ADU
Rms noise: 4.6647 e- ± 1.066

Wavelength [nm] QE [%] PRNU [rms %]
30046.52.8
31070.52.3
32068.31.9
33070.91.8
34072.71.6
35072.91.6
36072.61.6
37075.11.4
38080.11.2
39083.61.0
40085.70.9
42087.10.8
44087.00.8
46086.10.7
48084.60.7
50083.30.7
52082.30.7
54081.30.7
55081.30.7
56080.70.7
58080.00.7
60079.20.7
62078.20.7
64076.70.7
65072.50.7
Wavelength [nm] QE [%] PRNU [rms %]
66074.50.7
68072.10.8
70069.40.8
72066.30.9
74062.50.9
76058.11.0
78053.91.1
80049.31.3
82044.11.7
84038.81.8
86033.92.0
88028.92.2
90024.42.2
92019.22.2
94014.461.6
96010.71.6
9807.12.5
10004.13.2
10202.03.9
10400.65.1
10600.35.7
10800.26.0
11000.17.0

Click here for a   Comparison of QE performance of the previous CCD "MARLENE" and the new CCD "PAVAROTTI".


Back to   "UVES Scientific CCD System"

Send comments to   <odt@eso.org>
Last update: Jan 27, 2010
Webdesign by   EVI
 [ESO]  [Index]  [Search]  [Help]  [News]