mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
XSHOOTER:
lamps: arc & flat
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
XSHOOTER trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-12-22T09:24:52 (UT)
  | now: 2024-12-22T11:50:11 (UT) muc02 QC pipeline: xshoo-3.6.5a (installed 2023-09-18)
same group: flat_HC_IFU slice_rms   flat_IFU flat_SLIT arc_lamp spectrum SLIT stdev
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
XSHOOTER news:  
Report news:
DATE*: [?] 2024-12-15
report | NLT
2024-12-16
report | NLT
2024-12-17
report | NLT
2024-12-18
report | NLT
2024-12-19
report | NLT
2024-12-20
report | NLT
2024-12-21
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU/sec none  75 flux_1 this | last_yr | all DIT=5.0 sec maximum flux of lamp (after 2014-02-04)
2 QC1DB none   ADU none  75 counts_1 this | last_yr | all DIT=5.0 sec maximum counts in flat (after 2014-02-04)
3 QC1DB none   ADU/sec none  77 flux_1 this | last_yr | all DIT=12.0 sec maximum flux of lamp (after 2014-02-04)
4 QC1DB none   ADU VAL20000,35000 77 counts_1 this | last_yr | all DIT=12.0 sec maximum counts in flat (after 2014-02-04)
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:xshooter_flat
(QC1 database)
dataset:flux_1
average:none
thresholds:none
N_data plotted:75
[click plot for closeup]
Plot 2
scores: not implemented
data source:xshooter_flat
(QC1 database)
dataset:counts_1
average:none
thresholds:none
N_data plotted:75
[click plot for closeup]
Plot 3
scores: not implemented
data source:xshooter_flat
(QC1 database)
dataset:flux_1
average:none
thresholds:none
N_data plotted:77
[click plot for closeup]
Plot 4
scores: 8|
data source:xshooter_flat
(QC1 database)
dataset:counts_1
average:none
fixed thresholds:20000...35000ADU
N_data plotted:77
[click plot for closeup]
This plot

Here we monitor the lamp flux in ADU/sec and the flat counts in ADU of the daily acquired health check IFU flat. These HC IFU flats are composed of two raw frames only, one on-lamp and one off-lamp frame. The template is usually started twice a day, once at instrument startup with DIT=60sec and once at the end of the day-time calibrations with DIT=25sec.

The lamp flux is scored, the flat counts not.

For more information see the plot tutorial page.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up