mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
X-SHOOTER
QC links:
CAL
XSHOOTER calChecker: calibration completeness monitor
Last update: 2026-06-05T14:12:33 (UT)
[?]
  Paranal date*: 2026-06-04         muc02 [?]   server: eso.org PL
HELP ASSOC-RULES DETAILS
Last header: XSHOO. 2026-06-05T12:14:03.329.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services have been moved to qcFlow. These pages are only maintained for comparison and will be removed in 2026.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
TELL_VIS_0.57 7.6REMINDER: take as soon as possible
TELL_VIS_0.77 7.6REMINDER: take as soon as possible
TELL_VIS_0.97 7.6REMINDER: take as soon as possible
TELL_VIS_1.27 7.6REMINDER: take as soon as possible
TELL_VIS_1.57 7.6REMINDER: take as soon as possible
TELL_NIR_0.47 7.6REMINDER: take as soon as possible
TELL_NIR_0.67 7.6REMINDER: take as soon as possible
TELL_NIR_0.97 7.6REMINDER: take as soon as possible
TELL_NIR_1.27 7.6REMINDER: take as soon as possible
TELL_NIR_0.6JH7 7.6REMINDER: take as soon as possible
TELL_NIR_0.9JH7 7.6REMINDER: take as soon as possible
ARC_UVB_IFU14 97.9REMINDER: take as soon as possible!
ARC_VIS_IFU14 97.9REMINDER: take as soon as possible!
ARC_NIR_IFU14 97.9REMINDER: take as soon as possible!
EFFMON_UVB60177.3REMINDER: take as soon as possible!
EFFMON_VIS60177.3REMINDER: take as soon as possible!
EFFMON_NIR60177.3REMINDER: take as soon as possible!
LINEARITY_VIS_100k30 32.9REMINDER: take as soon as possible
XSHOOTER news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .  tellTracker   [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs: finished 13:48UT
DATE*:   [?]
[color if science data acquired]
2026-05-29
SM
28
report | NLT
2026-05-30

report | NLT
2026-05-31

report | NLT
2026-06-01
SM
118
report | NLT
2026-06-02

report | NLT
2026-06-03
SM
15
report | NLT
2026-06-04
SM
6
report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw raw      
P...
CAL product quality:     [?]
products products products products products products products      
Data types: Setup:        
SCI_SLIT_UVB 100k_hg_1x1_0.5x11 ok
 
 
ok
 
nok
[not yet analyzed]
 
  STD_FLUX_SLIT_UVB 100k_hg_1x1_0.5x11
100k_hg_1x1_1.0x11  
 
 
ok
 
 
 
  all ok  
100k_hg_1x1_1.3x11  
 
 
ok
 
 
 
  all ok  
100k_hg_1x1_5.0x11  
 
 
ok
 
 
 
  all ok  
100k_hg_2x2_1.0x11 ok
 
 
ok
 
 
nok
[daycals finished; problem not yet analyzed]
  STD_FLUX_SLIT_UVB 100k_hg_2x2_1.0x11
SCI_SLIT_VIS 100k_hg_1x1_0.7x11 ok
 
 
ok
 
nok
[not yet analyzed]
 
  STD_FLUX_SLIT_VIS 100k_hg_1x1_0.7x11
100k_hg_1x1_0.9x11  
 
 
ok
 
 
 
  all ok  
100k_hg_1x1_5.0x11  
 
 
ok
 
 
 
  all ok  
100k_hg_2x2_0.9x11 ok
 
 
ok
 
 
nok
[daycals finished; problem not yet analyzed]
  STD_FLUX_SLIT_VIS 100k_hg_2x2_0.9x11
SCI_SLIT_NIR 40.0000_3_5.0x11  
 
 
ok
 
 
 
  all ok  
175.0000_4_0.9x11  
 
 
ok
 
 
 
  all ok  
250.0000_1_0.6x11 ok
 
 
ok
 
nok
[not yet analyzed]
 
  STD_FLUX_SLIT_NIR 250.0000_1_0.6x11
300.0000_1_0.6x11  
 
 
ok
 
nok
[not yet analyzed]
 
  STD_FLUX_SLIT_NIR 300.0000_1_0.6x11
600.0000_1_0.9x11 ok
 
 
ok
 
 
nok
[daycals finished; problem not yet analyzed]
  STD_FLUX_SLIT_NIR 600.0000_1_0.9x11
900.0000_1_0.6x11  
 
 
ok
 
 
 
  all ok  
 
INFORMATION SPECIFIC TO XSHOOTER           [?]
The following keys are used to define a SCIENCE XSHOOTER setup:
INS.OPTI2.NAME (= IFU/SLOT)
INS.OPTI3/4/5.NAME (= slit width for different arms) (since 2011-12-07: not for 5 arcsec slits)
DET.WIN1.BINX/Y (= binning along x/y axis; UVB and VIS only)
DET.READ.CLOCK (= readout mode; UVB and VIS only)
DET.DIT (= exposure time, NIR only)
DET.NDIT (= number of averaged exposures, NIR only)
CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 12
Range of days for the calibration memory (issue memory plus longest validity): 15
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT