[ ESO ]

Workflow information system for QC

 

WISQ
Other ...
   XSHOOTER: telluric IDPs
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
Workflow information system for QC  
Last update: 2024-11-04T04:58:49 (UT)
  | now: 2024-11-05T00:24:06 (UT)  
same group: SNR_Tell:_UVB VIS NIR
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Report news: Data before 2013-01 show a distinctively steeper curve, because of major pipeline change (v1.x to v2.x) [qc_xshooter@eso.org]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 .QC1DB none   ratio none  134 qc_s2n this | last_yr | all 1. Low gain, 1x1 bin, tellurics: any mode, any slit.
1 oQC1DB none   ratio none  6 qc_s2n this | last_yr | all Reference slit 0.5x11:
STARE mode (red dotted line: square root law)
1 oQC1DB none   ratio none  1 qc_s2n this | last_yr | all NODDING, N=2 (green dotted line: square root law)

2 .QC1DB none   ratio none  621 qc_s2n this | last_yr | all 2. High gain, 1x1 bin, tellurics: any mode, any slit.
2 oQC1DB none   ratio none  34 qc_s2n this | last_yr | all Reference slit 1.0x11:
STARE mode
2 oQC1DB none   ratio none  217 qc_s2n this | last_yr | all NODDING

3 .QC1DB none   ratio none  62 qc_s2n this | last_yr | all 3. Low gain, 2x2 bin, tellurics: any mode, any slit.
3 oQC1DB none   ratio none  12 qc_s2n this | last_yr | all Reference slit 1.0x11:
STARE mode
3 oQC1DB none   ratio none  25 qc_s2n this | last_yr | all NODDING

4 .QC1DB none   ratio none  252 qc_s2n this | last_yr | all 4. High gain, 2x2 bin, tellurics: any mode, any slit.
4 oQC1DB none   ratio none  147 qc_s2n this | last_yr | all Reference slit 1.0x11:
STARE mode
4 oQC1DB none   ratio none  34 qc_s2n this | last_yr | all NODDING
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
data source:xshooter_science_idp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_s2n.
average:none
thresholds:none
N_data plotted:134
[click plot for closeup]
Plot 2
data source:xshooter_science_idp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_s2n.
average:none
thresholds:none
N_data plotted:621
[click plot for closeup]
Plot 3
data source:xshooter_science_idp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_s2n.
average:none
thresholds:none
N_data plotted:62
[click plot for closeup]
Plot 4
data source:xshooter_science_idp
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_s2n.
average:none
thresholds:none
N_data plotted:252
[click plot for closeup]
This plot

This plot shows the mean signal-to-noise ratio of XSHOOTER tellurics as a function of the mean counts. Tellurics are telluric standard stars processed like science files as IDPs. They should ideally show, like the classical IDPs, a square-root law (indicated by the dotted lines which are NOT fits). Since their spectral characteristics are more uniform than for the IDPs, their correlation curves are expected to show less scatter.

For the UVB and VIS arm we display correlations for the two detector gain values offered (low gain = lg or high gain = hg) and the two mostly used binnings (1x1 binning or 2x2). We display the same reference slit widths as for the classical IDPs. The NOD values in plot #1 are for datancom=2 only.

Within each box we use different colors for the 2 observing techniques used for tellurics:

  • red for STARE (single exposure),
  • green for NODDING (exposure pairs, or multiple pairs).

We have added data points for all modes and slits for a given read mode and binning as small black points. We have also added (for the two upper, well-populated boxes) square-root laws for orientation. Note that they apply to the date range after 2013-01 only, due to a major pipeline change in that month. For the earlier data another normalization factor applies to the flat-field that is reflected in a different scale for the mean_counts parameter (X-axis). These relations are also plotted in the FULL plot (only), marked by that date.

In the NIR-arm, the left box is for the STARE mode observations including the mapping template observations which are processed by the STARE pipeline recipe. The right box displays the NODDING data, broken down by the reference slit width and the most frequently used values of N (PRO.DATANCOM, the total number of combined raw frames).  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up