mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
detector: dark
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
SPHERE trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-23T04:53:10 (UT)
  | now: 2024-11-23T07:08:46 (UT) muc03 QC pipeline: spher-0.56.0 (installed 2024-09-26)
same group: med_master ron NumHotPix persistence persist/temp   Background NormPersist
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
SPHERE news: Note that the current Health Check monitor runs with an incomplete pipeline and an incomplete set of QC1 parameters. QCG can currently not guarantee completeness and significance at the usual level.
Report news: 2022-04-16 Red flat on ron is of unknown origin. QC1 database and products don't show any value out of range.

Please disregard this flag. [pfluxa@eso.org]
DATE*: [?] 2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
report | NLT
2024-11-22
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 5.11768 ADU VAL1,7 21 qc_ron this | last_yr | all setup: DIT=2, NDIT=40, Nondest
2 QC1DB MEDIAN 6.82281 ADU VAL4,9 21 qc_ron this | last_yr | all setup: DIT=8, NDIT=25, Nondest
3 QC1DB MEDIAN 11.4129 ADU VAL5,17 21 qc_ron this | last_yr | all setup: DIT=30, NDIT=15, Nondest
4 QC1DB none   NONE none  440 qc_ron this | last_yr | all ron as function of DIT
5 QC1DB none   NONE none  440 temp_bench this | last_yr | all IFS optical bench temperature
6 QC1DB none   NONE none  21 qc_ron this | last_yr | all setup: DIT=2, NDIT=40, Nondest
6 QC1DB none   NONE none  21 qc_ron this | last_yr | all setup: DIT=8, NDIT=25, Nondest
6 QC1DB none   NONE none  21 qc_ron this | last_yr | all setup: DIT=30, NDIT=15, Nondest
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 3|
data source:sphere_ifs_dark
(QC1 database)
dataset:qc_ron
median:5.11768ADU
fixed thresholds:1...7ADU
N_data plotted:21
[click plot for closeup]
Plot 2
scores: 3|
data source:sphere_ifs_dark
(QC1 database)
dataset:qc_ron
median:6.82281ADU
fixed thresholds:4...9ADU
N_data plotted:21
[click plot for closeup]
Plot 3
scores: 3|
data source:sphere_ifs_dark
(QC1 database)
dataset:qc_ron
median:11.4129ADU
fixed thresholds:5...17ADU
N_data plotted:21
[click plot for closeup]
Plot 4
scores: not implemented
data source:sphere_ifs_dark
(QC1 database)
dataset:qc_ron
average:none
thresholds:none
N_data plotted:440
[click plot for closeup]
Plot 5
scores: not implemented
data source:sphere_ifs_dark
(QC1 database)
dataset:temp_bench
average:none
thresholds:none
N_data plotted:440
[click plot for closeup]
Plot 6
scores: not implemented
data source:sphere_ifs_dark
(QC1 database)
dataset:
(numbers below apply to this dataset)
qc_ron
average:none
thresholds:none
N_data plotted:21
[click plot for closeup]
This plot

The QC parameter qc_ron is not calculated by the pipeline but by a QC script. From the raw frame fits cube, five planes are extracted (plane 6 to 10), and for each pixel the stdev (out of five independent reads) is calculated. The median over all pixels stdev is taken.

The parameter qc_ron contains statistical noise, which is composed of a static detector readout noise component of 2.47 ADU and a exposure time dependent component of

sqrt(counts / gain)

corresponding to the shot noise induced by the background radiation. In box (4) the function 2.47 + sqrt(-6 + 10.2 * DIT / 3.6) is overplotted.

The three reference setups (DIT=2, 8, and 30) are scored according to the dashed lines in boxes 1,2, and 3. All other setups are scored according to the non-linear arithmetic relation indicated by the dashed curves in box 4.

  • upper threshold = sqrt((-6 + 10.2 * DIT)/3.6)+2.47 -2.0-0.1*DIT
  • lower threshold = sqrt((-6 + 10.2 * DIT)/3.6)+2.47 +3.0+0.1*DIT
 
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up