The names of all pipeline products follow a certain naming convention. This is done to have human-readable rather than technical file names. The naming scheme has been chosen to have the type of product, its date of creation, and its pipeline-relevant parameter values all recognizable from the product name.
Since the begin of period 75 (April 2005), both science and calibration product files are renamed. (Actually, there was a transition phase extending for some instruments from April towards the end of the year 2005).
Before that date only calibration products followed the common scheme which is described here. (Some instruments had their own naming scheme which is described below, if applicable).
The general format of user-oriented product file names is the same for all VLT/VLTI instruments.
Instrument code
All pipeline product names start with two letters which are specific for the instrument. For instance: UVES product names start with 'UV', VISIR names with 'VR'.
Type of product
Next, the product type is coded. The full value is coded in the fits header key HIERARCH.ESO.PRO.CATG. A short form of this tag is coded in four characters being unique per instrument:
1st letter
M or P
calibration product
S
science product
G
general calibration product (as of P82)
2nd to 4th letter
...
type of product
instrument code
With the beginning of 2006 all ISAAC calibration product and science product names have changed as part of a major upgrade. The product names start with IS_.
All products based on observations and calibrations taken before 2006 follow the old naming scheme.
product type
The type of product is coded with four letters:
1st letter
S
for science
1st letter
M
for master calibration
1st letter
P
for calibration products
2nd - 4 th letter
.[A-Z][A-Z][A-Z]
for product specific naming
Table 1: composition of the 4-letter product code
calibration product letter code
The following Table 2 shows the naming convention, the product category key given in the product header and short description of the calibration product type:
Code
PRO.CATG
Type of file
IS_PSLT
SLIT_DESC
through slit image
IS_PIZP
ZPOINT
photometric zeropoint image
IS_PZPT
ZP_TAB
photometric zeropoint table
IS_MDRK
MASTER_DARK
master dark
IS_MFLI
MASTER_IMG_FLAT
master imaging flat twilight
IS_MERR
MASTER_IMG_ERRMAP
errormap of master imaging flat
IS_MBPX
MASTER_BPM
bad pixel map
IS_MINT
MASTER_IMG_INTERCEP
interception map
IS_PACT
ARC_CORRECT, LW_ARC_CORRECT
distortion corrected arc lamp image for SW-arm and LW-arm respectively
IS_PACF
ARC_COEF, LW_ARC_COEF
distortion and dispersion coefficients for SW-arm and LW-arm respectively
IS_MFLS
MASTER_SP_FLAT, LW_MASTER_SP_FLAT
master spectroscopic flat (SW, LW)
IS_PSTC
STAR_TRACE_COEF, LW_STAR_TRACE_COEF
startrace disortion coefficients (SW, LW)
IS_PSTE
STAR_TRACE_EXTR, LW_STAR_TRACE_EXTR
extracted startrace spectrum (SW, LW)
IS_PSTP
STAR_TRACE_POSI, LW_STAR_TRACE_POSI
startrace positions (between imaging and expected spectrum), SW, LW
IS_PSTS
STAR_TRACE_SHAPE, LW_STAR_TRACE_SHAPE
startrace shapes (SW, LW)
IS_PILL
ILLUM_FRAME
illumination 2d-fit correction image
IS_PILX
ILLUM_FLUX
illumination flux values
IS_PLIA
DETLIN_A
linearity A-coefficient image
IS_PLIB
DETLIN_B
linearity B-coefficient image
IS_PLIC
DETLIN-C
linearity C-coefficient image
IS_PLIQ
DETLIN-Q
linearity Q-coefficient image
IS_PCOM
SPECTRA_COMBINED, LW_SPECTRA_COMBINED
coadded standard star spectrum image (SW, LW)
IS_PEXT
SPEC_EXTRACTED, LW_SPEC_EXTRACTED
extracted standard star spectrum (SW, LW)
Table 2: calibration product naming scheme
Static calibration product letter code
With P82 (October 2008), the static
calibration products are also named according to the standard
ISAAC naming scheme. Before that date their names did not follow
a strict naming scheme. The following table lists the codes in the new name scheme:
Code
PRO.CATG
Type of file
IS_GARL
CALPRO_XE_CATALOG
Xe lines catalog
IS_GOHL
CALPRO_OH_CATALOG
OH lines catalog
IS_GXEL
CALPRO_AR_CATALOG
Ar lines catalog
IS_GSTS
STDSTARS_CATS
standard stars catalog
IS_GSED
SEDS
IS_GRCF
REF_CHECKFLAT
Table 3: Static calibration product naming scheme
science product letter code
The following Table 4 shows the types of science products:
Code
PRO.CATG
Type of file
IS_SICO
COADDED_IMG, LW_COADDED_IMG
science coadded image, (SW, LW)
IS_SISO
STARS_TAB
table of extracted sources
IS_SISK
SKY_TAB
table of sky background values
IS_SCOM
OBS_COMBINED
science co-added spectrum
IS_SEXT
OBS_EXTRACTED
science extracted spectrum
Table 4: science product naming scheme
date
The date of origin is identical to the date of the raw data measurement. It is coded as, e.g., YYMMDD (e.g. 000915 for Oct 15, 2000). The version of a file is indicated by capital letters always starting with A.
instrumental parameters
For calibration products the following setup parameters are included:
darks: arm, readmode, DIT : (e.g. IS_MDRK_060101A_SW_NonDest_120.fits)