mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
FLAMES/GIRAFFE:
lamps: stability
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
GIRAFFE trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-22T16:35:22 (UT)
  | now: 2024-11-23T02:18:06 (UT) muc02 QC pipeline: giraf-2.16.14 (installed 2024-10-16)
same group: SIM-lamp FF-lamp ARC-lamp   NAS-lamp
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
GIRAFFE news:  
Report news:
DATE*: [?] 2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
report | NLT
2024-11-22
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.41 counts/sec VAL0.30,0.5 38 lamp_effic this | last_yr | all ARCLAMP efficiency; H525.8B, Medusa1
2 xQC1DB MEDIAN 0.408 counts/sec VAL0.30,0.5 25 lamp_effic this | last_yr | all as plot 1, Medusa2
3 QC1DB MEDIAN 0.0842 counts/sec VAL0.06,0.10 12 lamp_effic this | last_yr | all as plot 1, IFU1 (Y scale 0...0.7)
4 QC1DB MEDIAN 0.0901 counts/sec VAL0.06,0.10 15 lamp_effic this | last_yr | all as plot 1, IFU2 (Y scale 0...0.7)
5 QC1DB MEDIAN 0.0536 counts/sec VAL0.03,0.08 14 lamp_effic this | last_yr | all as plot 1, Argus (Y scale 0...0.7)
6 xQC1DB MEDIAN 2.63 counts/sec VAL1.6,3.5 34 lamp_effic this | last_yr | all ARCLAMP efficiency; L543.1, Medusa1
7 xQC1DB MEDIAN 2.53 counts/sec VAL1.6,3.5 25 lamp_effic this | last_yr | all ... same for Medusa2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 3|
data source:giraffe_wave
(QC1 database)
dataset:lamp_effic
median:0.41counts/sec
fixed thresholds:0.3...0.5counts/sec
N_data plotted:38
[click plot for closeup]
Plot 2
scores: 3|
data source:giraffe_wave
(QC1 database)
dataset:lamp_efficx
median:0.408counts/sec
fixed thresholds:0.3...0.5counts/sec
N_data plotted:25
[click plot for closeup]
Plot 3
scores: 2|
data source:giraffe_wave
(QC1 database)
dataset:lamp_effic
median:0.0842counts/sec
fixed thresholds:0.06...0.1counts/sec
N_data plotted:12
[click plot for closeup]
Plot 4
scores: 3|
data source:giraffe_wave
(QC1 database)
dataset:lamp_effic
median:0.0901counts/sec
fixed thresholds:0.06...0.1counts/sec
N_data plotted:15
[click plot for closeup]
Plot 5
scores: 2|
data source:giraffe_wave
(QC1 database)
dataset:lamp_effic
median:0.0536counts/sec
fixed thresholds:0.03...0.08counts/sec
N_data plotted:14
[click plot for closeup]
Plot 6
scores: 3|
data source:giraffe_wave
(QC1 database)
dataset:lamp_efficx
median:2.63counts/sec
fixed thresholds:1.6...3.5counts/sec
N_data plotted:34
[click plot for closeup]
Plot 7
scores: 3|
data source:giraffe_wave
(QC1 database)
dataset:lamp_efficx
median:2.53counts/sec
fixed thresholds:1.6...3.5counts/sec
N_data plotted:25
[click plot for closeup]
This plot

This is the Health Check plot to monitor the efficiency of the GIRAFFE arclamp. We display the QC1 parameter lamp_effic which is the average (mean intensity/EXPTIME) flux of all emission lines, in ADU/sec, for all fibres except for the SIMCAL fibres.

This plot monitors the HC data taken in high resolution (H525.8B, all slits, box 1-5) and low resolution (L543.1, Medusa1 and 2 only, boxes 6 and 7).

If the intensity drops in one of the fibre systems, there is most likely a problem with that fibre system. If the fibre systems all drop simultaneously, this is likely to be a problem with the calibration lamp itself.

The quality of the arclamp exposures is quite critical for the quality of the dispersion solution. An intensity drop increases the rms of the dispersion solution significantly (see rms plot under "wavelength calibration", around epoch 2007-10).
 


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up