mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
FORS2:
lamps: arcs+flats
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
FORS2 trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-22T17:06:10 (UT)
  | now: 2024-11-23T03:13:05 (UT) muc01 QC pipeline: fors-5.6.10 (installed 2024-04-19)
same group: FFB12 FFB34 FFR34   Ar12 HeHgCd Ne12
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
FORS2 news:  
Report news:
DATE*: [?] 2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
report | NLT
2024-11-22
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
- general comment On 2016-04-18 lamp FlatBlue+4 was disabled and removed; Only lamp FlatBlue+3 has been used since then.
- general comment On 2015-03-02 exposure times for spectroscopic flats with FlatBlue+4 have been doubled; thresholds were therefore decreased by 50%.
- general comment On 2010-02-11 exposure times for spectroscopic flats with FlatBlue+4 have been reduced by 20%; thresholds were therefore increased by 25%.
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   ADU VAL100,125 113 flux this | last_yr | all normalized flux of FlatBlue+3 lamp for chip 1
2 QC1DB none   ADU VAL75,100 113 flux this | last_yr | all normalized flux of FlatBlue+3 lamp for chip 2
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 1|
data source:fors2_lamp_chk
(QC1 database)
dataset:flux
average:none
fixed thresholds:100...125ADU
N_data plotted:113
[click plot for closeup]
Plot 2
scores: 1|
data source:fors2_lamp_chk
(QC1 database)
dataset:flux
average:none
fixed thresholds:75...100ADU
N_data plotted:113
[click plot for closeup]
This plot

This parameter is determined from an overscan-subtracted calibration lamp exposure in LSS mode (taken with the template FORS2_lss_tec_flatLampcheck). The total signal is integrated and normalized by the exposure time and the total number of original CCD pixels (keeping into account possible binning). More information can be found in the plot tutorial. The setup of the lamp check is G300V, GG435 and 1arcsec slit.

  • FFB34 Monitoring the lamp flux of the two high brightness blue halogen lamps FlatBlue+3 and FlatBlue+4. These lamps are used to generate spectroscopic flats in blue (G300V, G600B) spectroscopic setups.

NOTE: On April 18, 2016 the FlatBlue+4 lamp was disabled and later taken out of the instrument's calibration unit. Since then, only FlatBlue+3 lamp is used for spectroscopic flats.
On November 15, 2016 the sub-plots relevant to the FlatBlue+4 lamp were removed.

DB Name: fors2_lamp_chk
TPL.ID: FORS2_lss_tec_flatLampcheck
QC1 DB parameter: flux

 
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up