mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
FORS2:
detector: monitoring
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
FORS2 trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T18:18:50 (UT)
  | now: 2024-11-22T10:05:53 (UT) muc01 QC pipeline: fors-5.6.10 (installed 2024-04-19)
same group: dark linearity gain flux_range   conad fp._noise
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
FORS2 news:  
Report news:
DATE*: [?] 2024-11-15
report | NLT
2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...               [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   e-/hr/px VAL-3,10 27 dark_avg this | last_yr | all dark level of Chip1, high gain
2 QC1DB none   e-/hr/px VAL3,8 27 sigma_dark_avg this | last_yr | all error of dark level of Chip1, high gain
3 QC1DB none   e-/hr/px VAL-3,10 27 dark_avg this | last_yr | all dark level of Chip2, high gain
4 QC1DB none   e-/hr/px VAL3,8 27 sigma_dark_avg this | last_yr | all error of dark level of Chip2, high gain
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 1|
data source:fors2_dark
(QC1 database)
dataset:dark_avg
average:none
fixed thresholds:-3...10e-/hr/px
N_data plotted:27
[click plot for closeup]
Plot 2
scores: 1|
data source:fors2_dark
(QC1 database)
dataset:sigma_dark_avg
average:none
fixed thresholds:3...8e-/hr/px
N_data plotted:27
[click plot for closeup]
Plot 3
scores: 1|
data source:fors2_dark
(QC1 database)
dataset:dark_avg
average:none
fixed thresholds:-3...10e-/hr/px
N_data plotted:27
[click plot for closeup]
Plot 4
scores: 1|
data source:fors2_dark
(QC1 database)
dataset:sigma_dark_avg
average:none
fixed thresholds:3...8e-/hr/px
N_data plotted:27
[click plot for closeup]
This plot

Dark frames are taken rarely with 2x2 bin, low and high gain. Those with low gain usually have neglible dark current in ADU. The typical exposure time is 1800 sec. The FORS pipeline generates master DARKs from input raw DARKs with master BIAS subtracted. Dark current: is computed from the median master dark frame level in ADU/hr/px and transformed into electrons by using the conversion factor CONAD. More information can be found on the plot tutorial page

DB Name: fors2_dark
TPL.ID: img_cal_dark
Fits header keyword: NA, parameters calculated by QC script
QC1 DB parameter: dark_avg, sigma_dark_avg

 
General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up