VIRCAM trending system: HEALTH CHECK report
Last update: 2023-06-12T09:51:38 (UT)
(659d 02h:32m ago)
[enable javascript for displaying time difference!]
General news:
NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
VIRCAM news:
On March 6th, 2023, VIRCAM has been decommissioned after 13 years of operations.
Report news:
png:
Information and research:
- png file
- advanced studies:
QC1 browser |
QC1 plotter
2009-05-28: Scoring (red/green squares in the group bar and in the navigation bar) is on the
detector average (Fig. 1) and detector rms (Fig. 3) values alone.
2009-05-28: Scores of individual detector values (Fig. 4) are for detailed analysis but do not contribute to the
overall instrument score.
2010-02-25 detector average and RMS photometric zeropoints will no longer be scored.
2022-12-01 modified bad pixel map (channel #16 in chip #15 is flagged) is used for the twilight flat recipe and the photometric standard star recipe
in order to generate more robust zeropoints.
Plot?
Symb?
Source *
Average ?
Thresholds ?
N_ data
QC1 parameter
Data downloads
Remarks
method
value
unit
method
value
1
• QC1DB
MEDIAN
23.4
MAG
none
39
qc_magzpt
this |
last_yr |
all
Photometric Zeropoint Y, average over all 16 detectors
2
• QC1DB
MEDIAN
23.4
MAG
none
624
qc_magzpt
this |
last_yr |
all
Photometric Zeropoint Y, values of all detetcors
3
• QC1DB
MEDIAN
0.0428
MAG
none
39
qc_magzpt
this |
last_yr |
all
Photometric Zeropoint Y, stdev over all detectors
4
■ LOCAL
none
MAG
none
624
qc_magzpt
n/a
Score per Detector: Green = within the thresholds
4
■ LOCAL
none
MAG
none
0
qc_magzpt
n/a
Score per Detector: Red = beyond thresholds
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1 scores: not implemented
data source: vircam_photstd (QC1 database)
dataset: qc_magzpt •
median: 23.4 MAG
thresholds: none
N_data plotted: 39
[click plot for closeup]
Plot 2 scores: not implemented
data source: vircam_photstd (QC1 database)
dataset: qc_magzpt •
median: 23.4 MAG
thresholds: none
N_data plotted: 624
[click plot for closeup]
Plot 3 scores: not implemented
data source: vircam_photstd (QC1 database)
dataset: qc_magzpt •
median: 0.0428 MAG
thresholds: none
N_data plotted: 39
[click plot for closeup]
Plot 4 scores: not implemented
data source: local data source
dataset: (numbers below apply to this dataset) qc_magzpt ■
average: none
thresholds: none
N_data plotted: 624
[click plot for closeup]
This plot
The scoring thresholds of the individual chips used in box (4) are:
CHIP_16 22.45 24.45
CHIP_15 22.45 24.45
CHIP_14 22.45 24.45
CHIP_13 22.45 24.45
CHIP_12 22.45 24.45
CHIP_11 22.45 24.45
CHIP_10 22.45 24.45
CHIP_9 22.45 24.45
CHIP_8 22.45 24.45
CHIP_7 22.45 24.45
CHIP_6 22.45 24.45
CHIP_5 22.45 24.45
CHIP_4 22.45 24.45
CHIP_3 22.45 24.45
CHIP_2 22.45 24.45
CHIP_1 22.45 24.45
General information
Click on any of the plots to see a close-up version .
The latest date is indicated on top of the plot.
If configured,
data points belonging to the latest date are specially marked
statistical averages are indicated by a solid line, and thresholds by broken lines
outliers are marked by a red asterisk. They are defined as data points outside the
threshold lines
"aliens" (= data points outside the plot Y limits) are marked by a red arrow (↑ or ↓ )
you can download the data for each parameter set if the 'Data downloads' link shows up