[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
UVES trending system: HISTORY report
HELP USERS-GUIDE MORE
Last update: 2018-07-15T07:03:35 (UT)
same group: 520_Plate1 580_P1 860_P1   520_Plate2 580_P2 860_P2
close window history: 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017   2018   2019   2020 2021 2022 2023 2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 1.97 pixels none  3 mean_dx this | last_yr | all DeltaX between solution and Physical Model, from MOS FMTCHK data, 520.0nm, 1x1, Plate 2, RED UPPER CCD
2 QC1DB MEDIAN -0.157 pixels none  3 mean_dy this | last_yr | all DeltaY, same data set
3 QC1DB MEDIAN 686 pixels none  3 nlin_sel this | last_yr | all Number of lines used in the solution, same data set

4 QC1DB MEDIAN 0.54 pixels none  3 mean_dx this | last_yr | all DeltaX between solution and physical model, 520.0nm, 1x1, Plate 2, RED LOWER CCD
5 QC1DB MEDIAN -1.45 pixels none  3 mean_dy this | last_yr | all DeltaY, same data set
6 QC1DB MEDIAN 828 pixels none  3 nlin_sel this | last_yr | all Number of lines used in the solution, same data set
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:1.97pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 2
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:-0.157pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 3
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:686pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 4
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dx
median:0.54pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 5
data source:uves_fib_fmtchk
(QC1 database)
dataset:mean_dy
median:-1.45pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
Plot 6
data source:uves_fib_fmtchk
(QC1 database)
dataset:nlin_sel
median:828pixels
thresholds:none 
N_data plotted:3
[click plot for closeup]
This plot

This is the trending report for the grating stability in FLAMES/UVES, derived from the MOS format check calibrations taken with wavelength setting 520, 1x1 binning and Plate 2. These data are only rarely taken and plotted here for completeness. They are not scored to avoid redundancy with the plate 1 plot.

Find more inforamtion in the description of the corresponding plot for plate 1.

Find more information about FLAMES/UVES Grating Position monitoring here.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up