mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
PIONIER
QC links:
CAL
PIONIER calChecker: calibration completeness monitor
Last update: 2024-11-05T02:04:02 (UT)
[?]
  Paranal date*: 2024-11-04         muc05 [?]   server: eso.org PL
HELP ASSOC-RULES DETAILS
Last header: PIONI. 2024-11-05T00:04:39.258.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Long-term calibrations: none defined
PIONIER news:

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2024-10-29

report | NLT
2024-10-30
SM
20
report | NLT
2024-10-31

report | NLT
2024-11-01

report | NLT
2024-11-02

report | NLT
2024-11-03

report | NLT
2024-11-04

report | NLT
LOST?
[may require OB
grade review]
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
n/a n/a n/a n/a n/a n/a n/a      
P...
CAL product quality:     [?]
products products products products products products products      
Data types: Setup:        
SCIENCE_FRINGE OBSERV-H_26_6x1+248+58_3000_GRISM  
ok
 
 
 
 
 
  all ok  
 
INFORMATION SPECIFIC TO PIONIER           [?]
The following keys are used to define a SCIENCE PIONIER setup:

ins.opti2.name (GRISM/FREE/GRI+WOL)
det.polar (7100: High Sensitivity, 5000: Medium Sensitivity, 3000 and 1000: Low Sensitivity)
det.subwins (number of output used for the science: 24,26,52)
det.subwin1.geometry (geometry of the outputs)


DARKs should be taken with same ins.opti2.name and det.polar SPECTRAL_CALIBRATION and KAPPA_MATRIX with same ins.opti2.name

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 14
Range of days for the calibration memory (issue memory plus longest validity): 15
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   increm