mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
MIDI:
detector characteristics
Other HC:
QC links:
[an error occurred while processing this directive] [an error occurred while processing this directive]
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+R to enforce refresh of scores and dates]
MIDI trending system: HEALTH CHECK plot
Last update: 2011-10-17T08:48:58 (UT)
| now: 2024-06-29T21:17:18 (UT)
HELP USERS-GUIDE MORE
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
The links to KMOS, UVES, and ESPRESSO have been moved to a new section (qcFlow operational) at the lower part of the navigation bar.
Report news:  
DATE*: [?] 2015-02-27
report | NLT
2015-02-28
report | NLT
2015-03-01
report | NLT
2015-03-02
report | NLT
2015-03-03
report | NLT
2015-03-04
report | NLT
2015-03-05
no data | NLT
P...
Product quality:
products products products products products products no products
  last OPSLOG data:
2011-10-16*

last files ...
[an error occurred while processing this directive]
monitor
Print: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
[an error occurred while processing this directive]
Plot
?
Symb
?
Source
*
OPS?
**
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB yes (2) none   NONE VAL2000,3000 0 grism_A1 this | last_yr | all A1_GRISM (not scored)
*Data sources: QC1DB: QC1 database; LOCAL: local text file | **OPS: to indicate that OPSLOG data are included
Plot 1
scores: [an error occurred while processing this directive]
data source:midi_detlin
(QC1 database)
dataset:grism_A1
average:none
fixed thresholds:2000.0...3000.0NONE
N_data plotted:0
[click on plot for closeup]
average:none
fixed thresholds:2000.0...3000.0NONE
[click on plot for closeup]
This plot

The linearity of the MIDI detector is an indicator if the quality of its response curve. The pipeline calculate the coefficients of the polynomial fit of the average pixel value (over a windowed area) of the detector for 3 different configurations (image, prism and grism). The polynomial fit is: I(t) = A_0 + A_1 * t + A_2 * t^2, where I is the detector level in ADU and t the time in millisecond.  


General information

Click on any of the plots to see a close-up version.

If applicable, the latest values from Paranal ops logs are plotted as blue dots. More information about those values, including a download option, is available in the OPS column.

The latest date is indicated on top of the plot, data points belonging to that date are specially marked.

If configured,

  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up