mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
KMOS:
detector: dark
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
KMOS trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-12-21T15:25:09 (UT)
  | now: 2024-12-21T16:58:11 (UT) muc01 QC pipeline: kmos-4.0.3 (installed 2022-03-28)
same group: darkmed darkron badpix
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
KMOS news:  
Report news:
DATE*: [?] 2024-12-14
report | NLT
2024-12-15
report | NLT
2024-12-16
report | NLT
2024-12-17
report | NLT
2024-12-18
report | NLT
2024-12-19
report | NLT
2024-12-20
report | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw
P...
CAL product quality:
products products products products products products products
 
transfer   ngas [?]

scores&comments | FULL | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 4.75e+04 none VAL0,5.2E4 92 badpix this | last_yr | all Total number of bad pixels from dark exposures, DIT=60s, detector 1
2 QC1DB MEDIAN 3.79e+04 none VAL0,4.2E4 92 badpix this | last_yr | all Total number of bad pixels from dark exposures, DIT=60s, detector 2
3 QC1DB MEDIAN 1.52e+04 none VAL0,2.0E4 92 badpix this | last_yr | all Total number of bad pixels from dark exposures, DIT=60s, detector 3
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: 8|
data source:kmos_dark
(QC1 database)
dataset:badpix
median:4.75e+04none
fixed thresholds:0...52000.0none
N_data plotted:92
[click plot for closeup]
Plot 2
scores: 8|
data source:kmos_dark
(QC1 database)
dataset:badpix
median:3.79e+04none
fixed thresholds:0...42000.0none
N_data plotted:92
[click plot for closeup]
Plot 3
scores: 8|
data source:kmos_dark
(QC1 database)
dataset:badpix
median:1.52e+04none
fixed thresholds:0...20000.0none
N_data plotted:92
[click plot for closeup]
This plot

Total number of bad pixels in dark exposures. Only data points from darks with DIT=60s and from stacks of 5 exposures are included in this plot.

Until April 2016, also darks with DIT=600s were measured regularly. Historical plots have these data included. Note that the lower number of bad pixels on detector 1 for DIT=600s is due to the pipeline algorithm and not a detector feature.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up