mirror sites: PL (internal link) HQ     [?]

Calibration completeness monitor

 

[all links are internal]             [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of "ago" time information]
CAL | HC | refs | QC
CALCHECKER
  HOME | HELP
  sl icon ALL INSTRUMENTS
FORS2
QC links:
CAL
FORS2 calChecker: calibration completeness monitor (CAL4CAL)
Last update: 2024-11-22T03:14:40 (UT)
[?]
  Paranal date*: 2024-11-21         muc01 [?]   server: eso.org PL
HELP ASSOC-RULES DETAILS
Last header: FORS2. 2024-11-22T00:37:28.695.hdr
transfer     ngas    [?]
  *Date on this monitor changes at 21:00 UT. Refresh frequency: 1/2hr day and night
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
Long-term calibrations and maintenance complete overview | how to execute     [?]
type of calibration validity (days) age (days) evaluation
DETECTOR_MON_high_gain_2x2_MIT90 82.2soft REMINDER: next 34 day(s)
DETECTOR_MON_low_gain_1x1_MIT90 98.4REMINDER: take as soon as possible
LADC_FLAT_monitoring30 25.6soft REMINDER: next 13 day(s)
FORS2 news: A new entry regarding STD_PMOS is available in the Information Specific to FORS2 table.

       

HELP | Q&A | ASSOC-RULES   history... | contact   monitors: DataTransferMonitor | BandWidth
  science  .   cal4cal  .    [?]     Product availability depends on the data transfer to Garching and the archive access there (check the "transfer" and "ngas" flags above).
  daytime calibs:   pending
DATE*:   [?]
[color if science data acquired]
2024-11-15

report | NLT
2024-11-16
SM
8
report | NLT
2024-11-17

report | NLT
2024-11-18

report | NLT
2024-11-19
SM
8
report | NLT
2024-11-20
SM
4
report | NLT
2024-11-21

report | NLT
LOST?
[not applicable
for 'cal4cal']
Calibration action?     [?]
[take these data types ...
Setup:
... for these setups]
r...
Raw CAL displays:     [?]
raw raw raw raw raw raw raw      
P...
CAL product quality:     [?]
products products products products products products products      
Data types: Setup:        
STD_IMA 200Kps/low_SR_I_BESS_2x2  
 
 
 
 
ok
ok
  all ok  
200Kps/low_SR_I_BESS_Norma_2x2  
ok
 
 
 
 
 
  all ok  
200Kps/low_SR_R_SPECIAL_2x2  
 
 
 
 
ok
ok
  all ok  
200Kps/low_SR_R_SPECIAL_Norma_2x2  
ok
 
 
 
 
 
  all ok  
200Kps/low_SR_b_HIGH_2x2  
 
 
 
 
ok
ok
  all ok  
200Kps/low_SR_b_HIGH_Norma_2x2  
ok
 
 
 
 
 
  all ok  
200Kps/low_SR_v_HIGH_2x2  
 
 
 
 
ok
ok
  all ok  
200Kps/low_SR_v_HIGH_Norma_2x2  
ok
 
 
 
 
 
  all ok  
STD_IPOL 200Kps/low_SR_I_BESS_2x2  
 
 
 
 
 
ok
  all ok  
200Kps/low_SR_R_SPECIAL_2x2  
 
 
 
 
 
ok
  all ok  
200Kps/low_SR_b_HIGH_2x2  
 
 
 
 
 
ok
  all ok  
200Kps/low_SR_v_HIGH_2x2  
 
 
 
 
 
ok
  all ok  
STD_MOS 100Kps/high_SR_G300V_-22640_2x2  
 
 
 
 
ok
 
  all ok  
100Kps/high_SR_G600B_-22640_2x2  
 
 
 
 
ok
 
  all ok  
100Kps/high_SR_GG435_G300V_-22640_2x2  
 
 
 
 
ok
 
  all ok  
STD_PMOS 100Kps/high_SR_GG435_G300V_RETA2_0_Norma_2x2  
 
 
 
ok
 
 
  all ok  
 
INFORMATION SPECIFIC TO FORS2           [?]
The following keys are used to define a CALIB FORS2 setup:

det.read.clock (= 100Kps/2ports/high_gain, 200Kps/2ports/low_gain, 625Kps/2ports/low_gain)
ins.coll.name (= SR, HR)
ins.opti#.name (# = 5,6,7,9,10; polarization optics, grisms e.g. G300V, and filters e.g. z_SPECIAL, GG435)
seq.spec.targ (position of long slit produced by aligning MOS slitlets)
ins.mask.id (identification of MXU mask e.g. +905221)
det.win1.binx,det.win1.biny (= 1x1, 2x2)

CONFIGURATION           [?]
Number of days scanned: 7
Range of days for the issue memory (configured): 15
Range of days for the calibration memory (issue memory plus longest validity): 20
Days in the calibration&issue memory:
*Date on this monitor changes at: 21:00 UT
powered by QC [calChecker v4.6.8]   full