GIRAFFE ARGUS CALSELECTOR calibration cascade

DFOS_OPS | CALCHECKER | CALSELECTOR (current) || select other instrument: OCA
OCA rule set:GIRAFFE_raw2master.2004-03-28.RLS | other versions
Start-date:2004-03-28
Type of rule set:CALSELECTOR (raw2master type of association; versioning supported)
Sub-cascades: ALL       MEDUSA | IFU | ARGUS
General comment:For processing, NFLATs are used. STD and FFLATs are added as MASSOCs.

Mouse over ...
- a RAW_TYPE to check out the classification rule (M marks a multiple definition)
- a grouping rule to see the complete grouping rule
- a matching rule (e.g. '1,1') to see the product matching rule.
Product tags etc. might be cut off, in that case mouse over the cell to see the full entry.

Time match rules:
GT: no validity for this static mcalib defined
T: no validity for this mcalib defined
< PREVIOUS time match
||-7.0/+7.0  calib_plan validity (best mjd_obs time difference) and extended validity defined
(-2.0/+2.0)  calib_plan validity not defined, only extended validity (maximum mjd_obs time difference)
[-2.0/+2.0]  calib_plan validity defined, but no extended validity

bottom | right left     
RAW_TYPEACQ BIAS DARK FFLAT NFLT WAVE STD_ARG SCI_ARG M
DO_CLASSACQ_FACB BIAS DARK FIBER_FLAT NASMYTH_FLAT ARC_SPECTRUM STD_ARG SCI_OZPOZ_ARG,
SCI_SIMCAL_ARG
CATGACQUISITION CALIB CALIB CALIB CALIB CALIB CALIB SCIENCE
Grouping rule single TPL_A TPL_A TPL_A TPL_A single single single
Recipe none gimasterbias gimasterdark gimasterflat gimasterflat giwavecalibration gistandard giscience
Index12345678

Calibration cascade:
static mcalibs:master calibs:
1 GRATING_DATA       1,1 GT 1,1 GT 1,1 GT 1,1 GT 1,1 GT
2 SLIT_GEOMETRY_SETUP       1,1 GT 1,1 GT 1,1 GT 1,1 GT 1,1 GT
3 BAD_PIXEL_MAP               0,1 GT
4 LINE_MASK               0,1 GT
6 ATMOSPHERIC_EXTINCTION             1,1< 0,1< MASSOC
7 FLUX_STANDARDS             1,1< 0,1< MASSOC
8 LINE_CATALOG           1,1 GT    
9 REFERENCE_DISP_SOLUTION           1,1 GT    
    10 MASTER_BIAS 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
      11 MASTER_DARK         0,1 ||-30/+30
        12 FF_EXTERRORS       0,1 ||-2.5/+2.5 MASSOC
        13 FF_EXTSPECTRA       0,1 ||-2.5/+2.5 MASSOC
        14 FF_LOCCENTROID   1,1 ||-2.5/+2.5   0,1 ||-2.5/+2.5 MASSOC
        15 FF_LOCWIDTH   1,1 ||-2.5/+2.5   0,1 ||-2.5/+2.5 MASSOC
          16 NF_EXTERRORS   1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
          17 NF_EXTSPECTRA   1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
          18 NF_LOCCENTROID   1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
          19 NF_LOCWIDTH   1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
            20 ARC_RBNSPECTRA   0,1 ||-2.5/+2.5 MASSOC
            21 DISPERSION_SOLUTION 1,1 ||-2.5/+2.5 1,1 ||-2.5/+2.5
              22 INSTRUMENT_RESPONSE 0,1 ||-10/+10 MASSOC
              23 STD_RBNSPECTRA 0,1 ||-10/+10 MASSOC
              24 STD_RCSPECTRA 0,1 ||-10/+10 MASSOC
                25 SCIENCE_RBNSPECTRA

Comments:
  RASSOC 0,5; same OB, same night   needed for removing CCD glow; optional since not always existing normal fibre flats (used for MEDUSA reduction) nasmyth flats with better illumin. (used for ARGUS reduction; MEDUSA: attached only, RASSOC)   relative flux calibration product added for proper grouping; LINE_MASK required for SCI_SIMCAL, BAD_PIXEL_MAP improves extraction, MASTER_DARK for better glow subtraction

Analysis (technical consistency checks):
raw_type* (CALIB only) n/a OK OK OK OK OK OK n/a
mcalibs** n/a n/a OK OK OK OK OK OK
powered by QC [createCalibMap v2.0.2] last update: 2015-06-08T13:22:39
*raw_type: is raw_type used in cascade? (CALIB only)
**mcalibs: are all required mcalibs, per raw_type, somewhere listed as products?
top