#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = 11_3_SAM #Central_Wavelength = 11.2115 #FWHM =0.552 # #Minimum_Wavelength = 9.966 #Maximum_Wavelength = 12.714 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.0781236 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=2848.05 #Aperture r0= 6.0 #Annulus rA1= 40 #Annulus rA2= 47.571 #Mean of first background file = 19275.8554688 # #encvalue wavelength transmission transmission_error 8497.0 9.966 0.0668738 0.0353943 8507.0 9.978 -0.0144052 0.0353943 8517.0 9.99 -0.00785189 0.0353943 8527.0 10.002 -0.0209645 0.0353943 8537.0 10.014 0.0363284 0.0353943 8547.0 10.026 -0.0288661 0.0353943 8557.0 10.038 -0.0122093 0.0353943 8567.0 10.05 0.11967 0.0353943 8577.0 10.062 0.0334643 0.0353943 8587.0 10.074 0.0318384 0.0353943 8597.0 10.086 -0.00164499 0.0353943 8607.0 10.098 0.0199451 0.0353943 8617.0 10.11 -0.035282 0.0353943 8627.0 10.122 0.0213562 0.0353943 8637.0 10.134 -0.0581571 0.0353943 8647.0 10.146 0.0436197 0.0353943 8657.0 10.158 0.00694869 0.0353943 8667.0 10.17 -0.0927816 0.0353943 8677.0 10.182 0.00792664 0.0353943 8687.0 10.194 -0.005987 0.0353943 8697.0 10.206 -0.032961 0.0353943 8707.0 10.218 -7.70937e-05 0.0353943 8717.0 10.23 0.0222772 0.0353943 8727.0 10.242 -0.0213437 0.0353943 8737.0 10.254 0.0284702 0.0353943 8747.0 10.266 -0.00890894 0.0353943 8757.0 10.278 -0.0302805 0.0353943 8767.0 10.29 -0.0348334 0.0353943 8777.0 10.302 0.0458053 0.0353943 8787.0 10.314 -0.0538104 0.0353943 8797.0 10.326 -0.0468776 0.0353943 8807.0 10.338 0.0115831 0.0353943 8817.0 10.35 -0.0378309 0.0353943 8827.0 10.362 0.0274326 0.0353943 8837.0 10.374 -0.0118446 0.0353943 8847.0 10.386 -0.0343672 0.0353943 8857.0 10.398 -0.0968748 0.0353943 8867.0 10.41 0.0350861 0.0353943 8877.0 10.422 -0.0177435 0.0353943 8887.0 10.434 0.00847383 0.0353943 8897.0 10.446 -0.0109022 0.0353943 8907.0 10.458 0.0552298 0.0353943 8917.0 10.47 0.0312059 0.0353943 8927.0 10.482 0.103914 0.0353943 8937.0 10.494 0.00502222 0.0353943 8947.0 10.506 -0.0124421 0.0353943 8957.0 10.518 0.016763 0.0353943 8967.0 10.53 0.070864 0.0353943 8977.0 10.542 0.0383496 0.0353943 8987.0 10.554 0.0672943 0.0353943 8997.0 10.566 0.00747857 0.0353943 9007.0 10.578 0.0378072 0.0353943 9017.0 10.59 0.0245842 0.0353943 9027.0 10.602 0.0899813 0.0353943 9037.0 10.614 0.0663843 0.0353943 9047.0 10.626 -0.0109406 0.0353943 9057.0 10.638 0.00846213 0.0353943 9067.0 10.65 0.0878148 0.0353943 9077.0 10.662 0.0182081 0.0353943 9087.0 10.674 0.0108457 0.0353943 9097.0 10.686 -0.112685 0.0353943 9107.0 10.698 0.06025 0.0353943 9117.0 10.71 0.0850871 0.0353943 9127.0 10.722 0.0786533 0.0353943 9137.0 10.734 0.0589715 0.0353943 9147.0 10.746 0.0787746 0.0353943 9157.0 10.758 0.0697243 0.0353943 9167.0 10.77 0.158253 0.0353943 9177.0 10.782 0.101926 0.0353943 9187.0 10.794 0.138764 0.0353943 9197.0 10.806 0.132619 0.0353943 9207.0 10.818 0.123949 0.0353943 9217.0 10.83 0.140794 0.0353943 9227.0 10.842 0.161348 0.0353943 9237.0 10.854 0.202373 0.0353943 9247.0 10.866 0.20432 0.0353943 9257.0 10.878 0.243897 0.0353943 9267.0 10.89 0.270845 0.0353943 9277.0 10.902 0.326554 0.0353943 9287.0 10.914 0.291866 0.0353943 9297.0 10.926 0.366637 0.0353943 9307.0 10.938 0.438043 0.0353943 9317.0 10.95 0.540481 0.0353943 9327.0 10.962 0.557182 0.0353943 9337.0 10.974 0.537625 0.0353943 9347.0 10.986 0.620671 0.0353943 9357.0 10.998 0.705523 0.0353943 9367.0 11.01 0.670751 0.0353943 9377.0 11.022 0.745429 0.0353943 9387.0 11.034 0.765738 0.0353943 9397.0 11.046 0.803661 0.0353943 9407.0 11.058 0.834156 0.0353943 9417.0 11.07 0.812162 0.0353943 9427.0 11.082 0.932621 0.0353943 9437.0 11.094 0.925165 0.0353943 9447.0 11.106 0.912036 0.0353943 9457.0 11.118 0.959627 0.0353943 9467.0 11.13 1.0 0.0353943 9477.0 11.142 0.87495 0.0353943 9487.0 11.154 0.933277 0.0353943 9497.0 11.166 0.947224 0.0353943 9507.0 11.178 0.977472 0.0353943 9517.0 11.19 0.960581 0.0353943 9527.0 11.202 0.924758 0.0353943 9537.0 11.214 0.937395 0.0353943 9547.0 11.226 0.956614 0.0353943 9557.0 11.238 0.919052 0.0353943 9567.0 11.25 0.93183 0.0353943 9577.0 11.262 0.970936 0.0353943 9587.0 11.274 0.835488 0.0353943 9597.0 11.286 0.858722 0.0353943 9607.0 11.298 0.897063 0.0353943 9617.0 11.31 0.809509 0.0353943 9627.0 11.322 0.828137 0.0353943 9637.0 11.334 0.781297 0.0353943 9647.0 11.346 0.803755 0.0353943 9657.0 11.358 0.91849 0.0353943 9667.0 11.37 0.793501 0.0353943 9677.0 11.382 0.737879 0.0353943 9687.0 11.394 0.737726 0.0353943 9697.0 11.406 0.808921 0.0353943 9707.0 11.418 0.723177 0.0353943 9717.0 11.43 0.688369 0.0353943 9727.0 11.442 0.717571 0.0353943 9737.0 11.454 0.604412 0.0353943 9747.0 11.466 0.583955 0.0353943 9757.0 11.478 0.519726 0.0353943 9767.0 11.49 0.565633 0.0353943 9777.0 11.502 0.463291 0.0353943 9787.0 11.514 0.396243 0.0353943 9797.0 11.526 0.407698 0.0353943 9807.0 11.538 0.324455 0.0353943 9817.0 11.55 0.242494 0.0353943 9827.0 11.562 0.340426 0.0353943 9837.0 11.574 0.22663 0.0353943 9847.0 11.586 0.290043 0.0353943 9857.0 11.598 0.206816 0.0353943 9867.0 11.61 0.238166 0.0353943 9877.0 11.622 0.202575 0.0353943 9887.0 11.634 0.1858 0.0353943 9897.0 11.646 0.102952 0.0353943 9907.0 11.658 0.115913 0.0353943 9917.0 11.67 0.0551126 0.0353943 9927.0 11.682 0.131718 0.0353943 9937.0 11.694 0.072803 0.0353943 9947.0 11.706 0.0675921 0.0353943 9957.0 11.718 0.0928639 0.0353943 9967.0 11.73 0.0141459 0.0353943 9977.0 11.742 0.0634874 0.0353943 9987.0 11.754 0.0374849 0.0353943 9997.0 11.766 -0.0505121 0.0353943 10007.0 11.778 0.00606277 0.0353943 10017.0 11.79 0.0881553 0.0353943 10027.0 11.802 0.0616761 0.0353943 10037.0 11.814 -0.0278447 0.0353943 10047.0 11.826 0.065942 0.0353943 10057.0 11.838 0.0453943 0.0353943 10067.0 11.85 0.0605448 0.0353943 10077.0 11.862 -0.048404 0.0353943 10087.0 11.874 -0.0512435 0.0353943 10097.0 11.886 0.0741088 0.0353943 10107.0 11.898 0.0268559 0.0353943 10117.0 11.91 0.023483 0.0353943 10127.0 11.922 0.0703059 0.0353943 10137.0 11.934 0.00606915 0.0353943 10147.0 11.946 0.0360319 0.0353943 10157.0 11.958 -0.0260921 0.0353943 10167.0 11.97 -0.00688202 0.0353943 10177.0 11.982 -0.0350449 0.0353943 10187.0 11.994 0.00016989 0.0353943 10197.0 12.006 0.030469 0.0353943 10207.0 12.018 -0.101904 0.0353943 10217.0 12.03 -0.00706718 0.0353943 10227.0 12.042 -0.00756289 0.0353943 10237.0 12.054 0.00569822 0.0353943 10247.0 12.066 0.022847 0.0353943 10257.0 12.078 -0.0225238 0.0353943 10267.0 12.09 -0.0176689 0.0353943 10277.0 12.102 0.0550658 0.0353943 10287.0 12.114 0.0310511 0.0353943 10297.0 12.126 -0.00860689 0.0353943 10307.0 12.138 0.0090953 0.0353943 10317.0 12.15 0.0239659 0.0353943 10327.0 12.162 -0.0350265 0.0353943 10337.0 12.174 -0.064245 0.0353943 10347.0 12.186 0.00910441 0.0353943 10357.0 12.198 -0.0027042 0.0353943 10367.0 12.21 -0.0525658 0.0353943 10377.0 12.222 -0.00768612 0.0353943 10387.0 12.234 0.0213279 0.0353943 10397.0 12.246 -0.00522574 0.0353943 10407.0 12.258 -0.00264359 0.0353943 10417.0 12.27 -0.038958 0.0353943 10427.0 12.282 0.0249487 0.0353943 10437.0 12.294 0.050935 0.0353943 10447.0 12.306 -0.0336788 0.0353943 10457.0 12.318 0.0307134 0.0353943 10467.0 12.33 0.0370036 0.0353943 10477.0 12.342 0.115666 0.0353943 10487.0 12.354 0.0901886 0.0353943 10497.0 12.366 0.014957 0.0353943 10507.0 12.378 0.0157112 0.0353943 10517.0 12.39 0.0290234 0.0353943 10527.0 12.402 -0.0204521 0.0353943 10537.0 12.414 -0.0331674 0.0353943 10547.0 12.426 0.0041705 0.0353943 10557.0 12.438 -0.00351349 0.0353943 10567.0 12.45 -0.0282032 0.0353943 10577.0 12.462 -0.0460787 0.0353943 10587.0 12.474 -0.0140302 0.0353943 10597.0 12.486 -0.00785887 0.0353943 10607.0 12.498 -0.0752021 0.0353943 10617.0 12.51 0.00762705 0.0353943 10627.0 12.522 -0.0412077 0.0353943 10637.0 12.534 -0.0502917 0.0353943 10647.0 12.546 -0.0517186 0.0353943 10657.0 12.558 -0.0257175 0.0353943 10667.0 12.57 -0.00679172 0.0353943 10677.0 12.582 0.010996 0.0353943 10687.0 12.594 0.00437712 0.0353943 10697.0 12.606 -0.0332604 0.0353943 10707.0 12.618 0.0380889 0.0353943 10717.0 12.63 -0.0227194 0.0353943 10727.0 12.642 -0.0151736 0.0353943 10737.0 12.654 -0.00435101 0.0353943 10747.0 12.666 0.00197426 0.0353943 10757.0 12.678 -0.0415988 0.0353943 10767.0 12.69 0.00553358 0.0353943 10777.0 12.702 -0.016621 0.0353943 10787.0 12.714 -0.0125654 0.0353943