# Y filter curve @ T=87K # Y 3 (Iz881,SN003) # Wavelength (nm) T (%) 499.500 0.000462436 501.498 0.000181160 503.496 -0.000043000 505.494 -0.000437346 507.492 -0.000780242 509.490 0.000234739 511.488 -0.000388389 513.486 0.000120734 515.484 0.000003310 517.482 -0.000228683 519.480 0.000613431 521.478 -0.000247048 523.476 -0.000415678 525.474 0.000392582 527.472 0.000662704 529.470 -0.000446616 531.468 0.000595542 533.466 0.000421606 535.464 0.000636705 537.462 -0.000398581 539.460 -0.000191358 541.458 0.000838103 543.456 -0.000260135 545.454 -0.000666513 547.452 0.000376074 549.450 0.000564041 551.448 -0.000106388 553.446 -0.000285123 555.444 -0.000216161 557.442 0.000577638 559.440 0.000040500 561.438 -0.000131457 563.436 -0.000187144 565.434 0.000014900 567.432 0.000209539 569.430 -0.000317730 571.428 0.000366892 573.426 0.000658389 575.424 -0.000504915 577.422 0.000014500 579.420 0.000314906 581.418 -0.000265340 583.416 -0.000252096 585.414 0.000092000 587.412 0.000458499 589.410 0.000653561 591.408 -0.000513613 593.406 0.000654167 595.404 0.000336095 597.402 -0.000256415 599.400 0.000315558 601.398 0.000205117 603.396 0.000280394 605.394 -0.000050600 607.392 0.000003590 609.390 -0.000712606 611.388 0.000007120 613.386 0.000984173 615.384 0.000353062 617.382 -0.000118058 619.380 -0.000093500 621.378 -0.000055400 623.376 0.000063400 625.374 0.000283483 627.372 0.000702945 629.370 0.000490278 631.368 -0.000185224 633.366 -0.000668826 635.364 0.000896187 637.362 -0.000343579 639.360 0.000344770 641.358 0.000795261 643.356 0.000461127 645.354 0.000117375 647.352 -0.000178291 649.350 -0.000032200 651.348 -0.000156567 653.346 0.000342390 655.344 -0.000915306 657.342 0.000272489 659.340 -0.000243922 661.338 0.000155550 663.336 -0.000355422 665.334 -0.000003950 667.332 0.000068200 669.330 -0.000033300 671.328 0.000568743 673.326 0.000018900 675.324 -0.000123457 677.322 0.000476361 679.320 -0.000165452 681.318 -0.000533262 683.316 -0.000200392 685.314 -0.000097800 687.312 0.000290597 689.310 -0.000288378 691.308 0.000454456 693.306 0.000169140 695.304 0.000284970 697.302 0.000459800 699.300 -0.000002380 701.298 -0.000059900 703.296 0.000459993 705.294 -0.000542392 707.292 0.000180555 709.290 0.000129584 711.288 -0.000099300 713.286 -0.000576341 715.284 0.000798146 717.282 -0.000494286 719.280 -0.000013800 721.278 0.000343389 723.276 0.000663146 725.274 0.000420547 727.272 -0.000516613 729.270 -0.000146480 731.268 0.001341790 733.266 -0.000503897 735.264 0.000007650 737.262 -0.000227345 739.260 0.000720159 741.258 0.000929305 743.256 0.000167988 745.254 0.000238783 747.252 0.000010800 749.250 0.000083500 751.248 0.000152818 753.246 0.000465049 755.244 -0.000115674 757.242 0.000252764 759.240 0.000543433 761.238 0.000266334 763.236 -0.000080700 765.234 -0.000181900 767.232 0.000189048 769.230 -0.000320586 771.228 -0.000025400 773.226 0.000043400 775.224 -0.000174221 777.222 -0.000420284 779.220 0.000201156 781.218 0.000395039 783.216 -0.000434797 785.214 -0.000000899 787.212 0.000006090 789.210 0.000435328 791.208 -0.000581920 793.206 0.000478566 795.204 0.000374317 797.202 -0.000073700 799.200 0.000233260 801.198 0.000803148 803.196 0.000290905 805.194 0.000382032 807.192 -0.000299604 809.190 -0.000274938 811.188 0.000117885 813.186 -0.000518809 815.184 0.000080500 817.182 -0.000341177 819.180 0.000840284 821.178 0.000335201 823.176 0.000466244 825.174 -0.000310264 827.172 0.000540799 829.170 -0.013578769 831.168 0.001595130 833.166 -0.003627080 835.164 -0.010621669 837.162 -0.007180918 839.160 -0.007850101 841.158 -0.008504330 843.156 -0.009688525 845.154 -0.003827295 847.152 -0.006036357 849.150 -0.005042363 851.148 -0.012858903 853.146 -0.009148972 855.144 -0.007029081 857.142 -0.007492878 859.140 -0.007470869 861.138 -0.005753421 863.136 -0.006256914 865.134 -0.007743923 867.132 -0.010277057 869.130 -0.015599151 871.128 0.004585447 873.126 -0.003984480 875.124 -0.007738034 877.122 -0.007554220 879.120 -0.001196474 881.118 -0.006056323 883.116 -0.012917495 885.114 -0.010487249 887.112 -0.018222466 889.110 0.000862438 891.108 -0.007494864 893.106 -0.003015089 895.104 -0.006515515 897.102 -0.007577022 899.100 -0.009999938 901.098 -0.005024926 903.096 -0.006832470 905.094 -0.005292388 907.092 -0.009369731 909.090 -0.008212244 911.088 -0.008242606 913.086 -0.013825082 915.084 -0.002705946 917.082 -0.010318185 919.080 -0.005353701 921.078 -0.005131762 923.076 -0.006936080 925.074 0.002072870 927.072 0.018719386 929.070 0.023062183 931.068 0.011261292 933.066 0.008735294 935.064 0.010011826 937.062 0.014116760 939.060 0.033784326 941.058 0.060878485 943.056 0.130903244 945.054 0.281996787 947.052 0.563563526 949.050 0.970406651 951.048 1.354158759 953.046 1.598969698 955.044 1.765644193 957.042 2.059525967 959.040 2.714939117 961.038 4.087045193 963.036 7.208515644 965.034 14.082983017 967.032 28.158458710 969.030 49.898704529 971.028 70.498908997 973.026 82.999298096 975.024 89.162612915 977.022 91.734085083 979.020 92.684791565 981.018 92.964889526 983.016 92.985900879 985.014 92.623786926 987.012 91.866889954 989.010 91.176094055 991.008 90.931327820 993.006 91.318420410 995.004 91.992507935 997.002 92.496643066 999.000 92.626083374 1000.998 92.342010498 1002.996 91.996292114 1004.994 91.693153381 1006.992 91.530380249 1008.990 91.426696777 1010.988 91.261116028 1012.986 91.151763916 1014.984 91.234382629 1016.982 91.639244080 1018.980 92.240814209 1020.978 92.702888489 1022.976 92.872581482 1024.974 92.687812805 1026.972 92.402206421 1028.970 92.383071899 1030.968 92.731163025 1032.966 93.322402954 1034.964 93.695716858 1036.962 93.563758850 1038.960 92.945243835 1040.958 92.206443787 1042.956 91.774124146 1044.954 91.843292236 1046.952 92.385498047 1048.950 92.950942993 1050.948 93.152923584 1052.946 92.809379578 1054.944 91.931167603 1056.942 90.635299683 1058.940 88.820121765 1060.938 85.861854553 1062.936 81.049720764 1064.934 73.976852417 1066.932 64.516036987 1068.930 53.438919067 1070.928 42.057548523 1072.926 31.738456726 1074.924 23.533842087 1076.922 17.622877121 1078.920 13.349345207 1080.918 10.353338242 1082.916 8.183053017 1084.914 6.585665226 1086.912 5.320214748 1088.910 4.239126205 1090.908 3.317674637 1092.906 2.550049305 1094.904 1.929509282 1096.902 1.464773774 1098.900 1.118454576 1100.898 0.879506111 1102.896 0.716607809 1104.894 0.614790142 1106.892 0.545695126 1108.890 0.498980016 1110.888 0.465863109 1112.886 0.441258162 1114.884 0.410765350 1116.882 0.364719689 1118.880 0.303124368 1120.878 0.241135895 1122.876 0.181151271 1124.874 0.131206378 1126.872 0.094713844 1128.870 0.076412499 1130.868 0.056217484 1132.866 0.046777688 1134.864 0.039171029 1136.862 0.029684274 1138.860 0.035120353 1140.858 0.028321112 1142.856 0.030173086 1144.854 0.032031018 1146.852 0.030805916 1148.850 0.032624584 1150.848 0.036051620 1152.846 0.038187336 1154.844 0.033741277 1156.842 0.027945727 1158.840 0.021708863 1160.838 0.014109416 1162.836 0.010541240 1164.834 0.010060491 1166.832 -0.002728395 1168.830 0.013706649 1170.828 0.002473681 1172.826 0.002144329 1174.824 0.004582399 1176.822 0.003871910 1178.820 0.006119903 1180.818 -0.004212044 1182.816 0.011297207 1184.814 -0.002481922 1186.812 0.019345760 1188.810 0.007092402 1190.808 0.010909534 1192.806 0.016267342 1194.804 0.013033855 1196.802 0.004408498 1198.800 0.002517588 1200.798 -0.002162112 1202.796 -0.001379385 1204.794 -0.005384572 1206.792 0.002631138 1208.790 -0.001208494 1210.788 0.001105884 1212.786 0.001686505 1214.784 -0.008861020 1216.782 -0.003673932 1218.780 -0.006911405 1220.778 -0.004447128 1222.776 -0.004835404 1224.774 -0.008826191 1226.772 0.002989835 1228.770 0.000526446 1230.768 -0.008439092 1232.766 -0.003135674 1234.764 -0.003863251 1236.762 0.003386209 1238.760 0.002434032 1240.758 -0.001023912 1242.756 -0.011304512 1244.754 0.003741462 1246.752 -0.004083707 1248.750 -0.006580671 1250.748 -0.005021126 1252.746 -0.010908518 1254.744 -0.003696719 1256.742 -0.004286122 1258.740 -0.005564148 1260.738 -0.002553847 1262.736 -0.009956937 1264.734 -0.004851829 1266.732 -0.004963255 1268.730 -0.004788445 1270.728 -0.006699698 1272.726 -0.004853898 1274.724 -0.004461486 1276.722 0.001277576 1278.720 -0.007425667 1280.718 -0.006378702 1282.716 0.001608720 1284.714 -0.008179398 1286.712 0.008547890 1288.710 -0.004859337 1290.708 -0.005413747 1292.706 -0.001887502 1294.704 -0.008318861 1296.702 -0.008003363 1298.700 -0.001951228 1300.698 -0.010533959 1302.696 -0.008401679 1304.694 -0.002525056 1306.692 -0.012487737 1308.690 -0.000146348 1310.688 -0.012055547 1312.686 0.001045611 1314.684 -0.002431346 1316.682 0.001368436 1318.680 -0.005482477 1320.678 -0.007864719 1322.676 0.001149369 1324.674 -0.006715515 1326.672 -0.002987933 1328.670 -0.000300571 1330.668 -0.001142085 1332.666 0.004338961 1334.664 0.008198760 1336.662 0.012704342 1338.660 0.017271897 1340.658 0.016629204 1342.656 0.008268142 1344.654 0.006564056 1346.652 0.002116273 1348.650 -0.001833743 1350.648 -0.002206058 1352.646 -0.003012204 1354.644 -0.009251272 1356.642 0.004645851 1358.640 -0.001992589 1360.638 -0.001827102 1362.636 0.004645602 1364.634 0.007225963 1366.632 0.001536734 1368.630 -0.000022800 1370.628 0.011551049 1372.626 -0.001522447 1374.624 -0.000752815 1376.622 -0.002524848 1378.620 -0.005376488 1380.618 -0.002834907 1382.616 -0.007320007 1384.614 -0.006197078 1386.612 -0.007960289 1388.610 -0.000216097 1390.608 -0.003619236 1392.606 -0.003006558 1394.604 -0.001609822 1396.602 -0.001296508 1398.600 0.000646299 1400.598 0.000126591 1402.596 -0.007357628 1404.594 -0.005776523 1406.592 -0.005260133 1408.590 -0.000733458 1410.588 -0.004169995 1412.586 -0.002173738 1414.584 -0.005167583 1416.582 -0.005932049 1418.580 -0.005091289 1420.578 -0.005161972 1422.576 -0.004707560 1424.574 -0.004634197 1426.572 -0.008180979 1428.570 -0.002715865 1430.568 -0.002103522 1432.566 -0.009926461 1434.564 -0.001323834 1436.562 -0.002367727 1438.560 -0.008307881 1440.558 -0.003863384 1442.556 -0.008862341 1444.554 -0.011762136 1446.552 0.003333665 1448.550 0.000213987 1450.548 -0.002398594 1452.546 -0.007046437 1454.544 -0.006105601 1456.542 -0.001840907 1458.540 -0.009744215 1460.538 -0.003947317 1462.536 -0.002010994 1464.534 -0.009213286 1466.532 -0.005134436 1468.530 -0.006779439 1470.528 -0.004477126 1472.526 -0.002977596 1474.524 -0.008698352 1476.522 -0.005675202 1478.520 -0.010270308 1480.518 -0.002566413 1482.516 -0.006500168 1484.514 -0.005480577 1486.512 -0.007871712 1488.510 -0.004338281 1490.508 -0.004717298 1492.506 -0.010811814 1494.504 -0.005956518 1496.502 -0.004345862 1498.500 -0.005102532 1500.498 -0.005783560 1502.496 -0.004937597 1504.494 -0.006562878 1506.492 -0.008208105 1508.490 -0.002733860 1510.488 -0.006800647 1512.486 -0.007137880 1514.484 -0.007255768 1516.482 -0.006306252 1518.480 -0.006768092 1520.478 -0.003824091 1522.476 -0.004012223 1524.474 -0.006807356 1526.472 -0.006103763 1528.470 -0.003814542 1530.468 -0.006247867 1532.466 -0.002674368 1534.464 -0.008684683 1536.462 -0.003827236 1538.460 -0.005648675 1540.458 -0.005161357 1542.456 -0.004514870 1544.454 -0.006033732 1546.452 -0.007543347 1548.450 -0.004516614 1550.448 -0.009407387 1552.446 -0.005699690 1554.444 -0.003674209 1556.442 -0.004647155 1558.440 -0.005162833 1560.438 -0.005299426 1562.436 -0.003858448 1564.434 -0.003477015 1566.432 -0.001233599 1568.430 -0.000357439 1570.428 -0.006289433 1572.426 -0.004551976 1574.424 -0.002757270 1576.422 -0.005860838 1578.420 0.000019500 1580.418 -0.011856593 1582.416 -0.000922317 1584.414 -0.004850578 1586.412 -0.003400944 1588.410 -0.003279775 1590.408 -0.001835114 1592.406 -0.005575989 1594.404 -0.007987358 1596.402 -0.006327000 1598.400 -0.004095784 1600.398 0.000027200 1602.396 -0.007423148 1604.394 -0.000540661 1606.392 -0.001338055 1608.390 0.001658184 1610.388 -0.002460253 1612.386 -0.002211753 1614.384 -0.002074428 1616.382 -0.003142986 1618.380 -0.001492036 1620.378 -0.004807327 1622.376 0.004848034 1624.374 -0.005137948 1626.372 0.007603950 1628.370 -0.005469175 1630.368 -0.005967743 1632.366 -0.005784831 1634.364 -0.004998784 1636.362 -0.005783042 1638.360 -0.007407785 1640.358 -0.002772865 1642.356 -0.006662050 1644.354 -0.004625926 1646.352 -0.010021865 1648.350 -0.003315596 1650.348 -0.004845459 1652.346 -0.011700463 1654.344 -0.012852627 1656.342 -0.010326179 1658.340 0.010888983 1660.338 -0.013863297 1662.336 -0.004612911 1664.334 -0.009473169 1666.332 -0.001712787 1668.330 -0.007799162 1670.328 -0.004690257 1672.326 -0.004112403 1674.324 -0.003807593 1676.322 -0.007659263 1678.320 -0.005619206 1680.318 -0.003559508 1682.316 -0.002048275 1684.314 -0.003356945 1686.312 -0.003526655 1688.310 0.001418865 1690.308 -0.005614692 1692.306 -0.004445131 1694.304 -0.003799923 1696.302 -0.003204363 1698.300 -0.002115340 1700.298 -0.002349899 1702.296 -0.003247242 1704.294 -0.005468972 1706.292 -0.004844520 1708.290 -0.004920391 1710.288 -0.005209314 1712.286 -0.002064456 1714.284 -0.009688853 1716.282 -0.005397220 1718.280 -0.004215877 1720.278 -0.007114460 1722.276 -0.003818431 1724.274 -0.003056670 1726.272 -0.005639550 1728.270 -0.005072379 1730.268 -0.004334710 1732.266 -0.003228680 1734.264 -0.006512898 1736.262 -0.006357702 1738.260 -0.005990187 1740.258 0.000230076 1742.256 -0.004347104 1744.254 -0.001624433 1746.252 -0.005105712 1748.250 -0.004928870 1750.248 -0.007845080 1752.246 -0.005423664 1754.244 -0.005994012 1756.242 -0.005444069 1758.240 -0.002852477 1760.238 -0.002100277 1762.236 -0.010430543 1764.234 -0.002852841 1766.232 -0.004743282 1768.230 -0.001920273 1770.228 0.002508224 1772.226 -0.008248934 1774.224 -0.001409633 1776.222 -0.000242304 1778.220 -0.001544016 1780.218 -0.009055394 1782.216 -0.003262999 1784.214 -0.002943394 1786.212 -0.004197715 1788.210 -0.008348973 1790.208 -0.009495102 1792.206 -0.000482590 1794.204 -0.004720725 1796.202 -0.006645175 1798.200 -0.005640800 1800.198 -0.001363707 1802.196 -0.008258813 1804.194 -0.006431067 1806.192 -0.004056368 1808.190 -0.004709632 1810.188 -0.006409494 1812.186 -0.005879367 1814.184 -0.006427053 1816.182 -0.007136978 1818.180 -0.013466245 1820.178 0.005283991 1822.176 -0.011458889 1824.174 0.004162534 1826.172 -0.003537909 1828.170 -0.008367019 1830.168 0.001043734 1832.166 -0.005040142 1834.164 -0.009331834 1836.162 -0.002154837 1838.160 -0.003653994 1840.158 -0.007028763 1842.156 -0.008686374 1844.154 -0.002968061 1846.152 -0.006442529 1848.150 -0.001700646 1850.148 -0.004541877 1852.146 -0.011597112 1854.144 -0.006275078 1856.142 -0.005368514 1858.140 -0.011168161 1860.138 -0.011268476 1862.136 0.004866667 1864.134 -0.001592687 1866.132 -0.002233200 1868.130 -0.002417237 1870.128 -0.002243402 1872.126 -0.005695104 1874.124 -0.001029805 1876.122 0.003008209 1878.120 -0.008136388 1880.118 -0.003342201 1882.116 -0.006450772 1884.114 -0.000898005 1886.112 -0.005740981 1888.110 0.001300988 1890.108 -0.004073712 1892.106 -0.002751741 1894.104 -0.007092006 1896.102 -0.003944455 1898.100 -0.005750832 1900.098 -0.004800623 1902.096 -0.003112625 1904.094 -0.004548111 1906.092 -0.001649688 1908.090 -0.002589123 1910.088 -0.001887208 1912.086 -0.012687444 1914.084 0.001513489 1916.082 -0.003335814 1918.080 -0.001687361 1920.078 -0.002874478 1922.076 -0.000297789 1924.074 -0.005268722 1926.072 -0.004571609 1928.070 -0.003698190 1930.068 -0.003954946 1932.066 -0.010394069 1934.064 -0.004817691 1936.062 -0.005373923 1938.060 -0.002655196 1940.058 -0.003129943 1942.056 -0.005305161 1944.054 -0.010514078 1946.052 -0.006751196 1948.050 -0.007154519 1950.048 -0.001018725 1952.046 -0.008756865 1954.044 -0.007047695 1956.042 -0.004755305 1958.040 -0.004911822 1960.038 -0.011393356 1962.036 -0.005114394 1964.034 -0.006038214 1966.032 -0.007645717 1968.030 -0.000717869 1970.028 -0.008640511 1972.026 -0.006955971 1974.024 -0.005739774 1976.022 -0.004873621 1978.020 -0.007957899 1980.018 -0.005121053 1982.016 -0.016558295 1984.014 -0.003790311 1986.012 -0.006489534 1988.010 -0.005828105 1990.008 -0.007056226 1992.006 -0.002541740 1994.004 -0.001567936 1996.002 -0.002046056 1998.000 -0.005232633 1999.998 -0.008030021 2001.996 -0.004382543 2003.994 -0.004253244 2005.992 -0.003148023 2007.990 -0.003129147 2009.988 -0.003731250 2011.986 -0.006822740 2013.984 -0.004889709 2015.982 -0.004811865 2017.980 -0.004899341 2019.978 -0.004340163 2021.976 -0.000257388 2023.974 -0.005942344 2025.972 -0.002035951 2027.970 -0.005334517 2029.968 -0.007446165 2031.966 -0.004891885 2033.964 -0.003142266 2035.962 -0.001319746 2037.960 -0.005765928 2039.958 -0.000950659 2041.956 -0.011079225 2043.954 -0.004526460 2045.952 -0.004968083 2047.950 -0.004742989 2049.948 -0.004750923 2051.946 0.000938398 2053.944 -0.009380890 2055.942 -0.010766599 2057.940 -0.005301282 2059.938 -0.004874276 2061.936 -0.006260279 2063.934 -0.004557528 2065.932 -0.003836263 2067.930 -0.006243108 2069.928 -0.003641234 2071.926 -0.003695472 2073.924 -0.010627378 2075.922 -0.006204550 2077.920 -0.004176325 2079.918 -0.004593130 2081.916 -0.002385682 2083.914 -0.004250286 2085.912 -0.000575248 2087.910 -0.001365488 2089.908 -0.004140499 2091.906 -0.001883359 2093.904 -0.004662186 2095.902 -0.001921294 2097.900 -0.003531392 2099.898 -0.000691503 2101.896 -0.009821786 2103.894 0.008638075 2105.892 -0.002989624 2107.890 -0.003134197 2109.888 0.000725737 2111.886 -0.003007751 2113.884 -0.003100702 2115.882 0.001023684 2117.880 -0.001367623 2119.878 -0.001658934 2121.876 -0.002793330 2123.874 0.004238371 2125.872 -0.008209997 2127.870 -0.005781410 2129.868 -0.002402709 2131.866 -0.001001687 2133.864 0.000705659 2135.862 -0.003033498 2137.860 -0.005343991 2139.858 -0.001572119 2141.856 -0.006715731 2143.854 -0.008148010 2145.852 0.002309565 2147.850 -0.003889661 2149.848 -0.008392931 2151.846 -0.002602939 2153.844 -0.002646601 2155.842 -0.000695893 2157.840 -0.002061652 2159.838 0.000302737 2161.836 0.003112902 2163.834 -0.016928514 2165.832 0.002352042 2167.830 -0.005379189 2169.828 -0.002671129 2171.826 -0.002853408 2173.824 -0.002841613 2175.822 -0.000316345 2177.820 -0.011291326 2179.818 -0.006350617 2181.816 -0.002155104 2183.814 -0.008651213 2185.812 -0.002849332 2187.810 -0.004173409 2189.808 -0.006557386 2191.806 -0.004793098 2193.804 -0.008322012 2195.802 -0.004007624 2197.800 -0.008446991 2199.798 -0.005361196 2201.796 -0.006079371 2203.794 -0.005543472 2205.792 -0.003206121 2207.790 -0.004971906 2209.788 -0.005897494 2211.786 -0.002373523 2213.784 -0.006306194 2215.782 -0.012290958 2217.780 0.001079180 2219.778 -0.001620819 2221.776 -0.005776080 2223.774 -0.005378588 2225.772 -0.006601906 2227.770 -0.004630461 2229.768 -0.004686421 2231.766 -0.007354128 2233.764 -0.003055004 2235.762 -0.006160137 2237.760 -0.004815036 2239.758 -0.004750174 2241.756 -0.005386524 2243.754 0.000493102 2245.752 -0.003899862 2247.750 -0.008205742 2249.748 -0.011890300 2251.746 0.006369311 2253.744 -0.004983051 2255.742 -0.009516701 2257.740 -0.005119230 2259.738 -0.003775157 2261.736 -0.004722849 2263.734 0.000093900 2265.732 -0.012862691 2267.730 -0.004120728 2269.728 -0.003521328 2271.726 -0.002024158 2273.724 -0.004656500 2275.722 -0.006286744 2277.720 -0.007486457 2279.718 -0.008664614 2281.716 0.003806382 2283.714 -0.008015641 2285.712 -0.001673668 2287.710 -0.004517944 2289.708 0.000542725 2291.706 -0.002551320 2293.704 -0.003566905 2295.702 -0.000387863 2297.700 -0.001619005 2299.698 -0.006214957 2301.696 -0.002004407 2303.694 -0.004954031 2305.692 -0.000132388 2307.690 -0.003295023 2309.688 -0.001120700 2311.686 -0.000919488 2313.684 -0.004305968 2315.682 -0.001756729 2317.680 -0.005288907 2319.678 0.008443910 2321.676 0.004620137 2323.674 0.001106942 2325.672 0.001851190 2327.670 -0.000900654 2329.668 0.003264895 2331.666 -0.000144871 2333.664 -0.000025700 2335.662 0.002133245 2337.660 0.003522633 2339.658 0.005490777 2341.656 0.008545252 2343.654 0.003029732 2345.652 0.006692277 2347.650 0.008272850 2349.648 0.008273865 2351.646 0.010094261 2353.644 0.011195164 2355.642 0.013860308 2357.640 0.016510922 2359.638 0.018495170 2361.636 0.017729046 2363.634 0.020695275 2365.632 0.019519903 2367.630 0.014042130 2369.628 0.027350260 2371.626 0.021254610 2373.624 0.027922122 2375.622 0.017420322 2377.620 0.022357348 2379.618 0.020852780 2381.616 0.021113914 2383.614 0.021645283 2385.612 0.015514468 2387.610 0.009261277 2389.608 0.008178897 2391.606 0.029265845 2393.604 0.012495223 2395.602 0.016886467 2397.600 0.015439315 2399.598 0.014033430 2401.596 0.018661845 2403.594 0.018888948 2405.592 0.020035179 2407.590 0.008871426 2409.588 0.017390091 2411.586 0.021538841 2413.584 0.014559617 2415.582 0.010119839 2417.580 0.020079179 2419.578 0.018126743 2421.576 0.018199954 2423.574 0.017381752 2425.572 0.028421560 2427.570 0.018842597 2429.568 0.027191723 2431.566 0.024106259 2433.564 0.024578763 2435.562 0.013383455 2437.560 0.032011971 2439.558 0.029703612 2441.556 0.027364874 2443.554 0.026132315 2445.552 0.031765122 2447.550 0.029721368 2449.548 0.024246454 2451.546 0.022664687 2453.544 0.031386323 2455.542 0.024951493 2457.540 0.022103485 2459.538 0.022326406 2461.536 0.021453215 2463.534 0.016787749 2465.532 0.011152280 2467.530 0.016724981 2469.528 0.014265474 2471.526 0.009832475 2473.524 0.012293177 2475.522 0.011062354 2477.520 0.005279382 2479.518 0.018858615 2481.516 0.006966680 2483.514 0.008568304 2485.512 0.007496713 2487.510 0.009168261 2489.508 0.006670422 2491.506 0.010661738 2493.504 0.008257897 2495.502 0.005695016 2497.500 0.007038667 2499.498 0.010955345 2501.496 0.013108267 2503.494 0.010090670 2505.492 0.011763153 2507.490 0.004661033 2509.488 0.015223810 2511.486 0.009109029 2513.484 0.011451282 2515.482 0.027505815 2517.480 0.015350048 2519.478 0.017993782 2521.476 0.020565761 2523.474 0.025196519 2525.472 0.022242278 2527.470 0.027094726 2529.468 0.028044408 2531.466 0.022657489 2533.464 0.025146050 2535.462 0.029263064 2537.460 0.026186712 2539.458 0.026821837 2541.456 0.021951819 2543.454 0.022314627 2545.452 0.017800987 2547.450 0.018808475 2549.448 0.015182911 2551.446 0.016584057 2553.444 0.010886448 2555.442 0.017922908 2557.440 0.012390499 2559.438 0.006705166 2561.436 0.009625071 2563.434 0.006084281 2565.432 0.009473330 2567.430 0.008728733 2569.428 0.005408328 2571.426 0.007822630 2573.424 0.006852922 2575.422 0.008030294 2577.420 0.006734265 2579.418 0.008737982 2581.416 0.004438572 2583.414 0.003540845 2585.412 0.009755406 2587.410 0.005575315 2589.408 0.010000464 2591.406 0.008408982 2593.404 0.008912649 2595.402 0.007717670 2597.400 0.011864260 2599.398 0.014072193 2601.396 0.013107869 2603.394 0.015993413 2605.392 0.015089477 2607.390 0.022127476 2609.388 0.016497901 2611.386 0.024116946 2613.384 0.018321287 2615.382 0.026328908 2617.380 0.027670555 2619.378 0.026606945 2621.376 0.028654670 2623.374 0.031379398 2625.372 0.023698324 2627.370 0.026382381 2629.368 0.026932862 2631.366 0.023974791 2633.364 0.014745984 2635.362 0.030670347 2637.360 0.021862248 2639.358 0.023263380 2641.356 0.009574593 2643.354 0.013401383 2645.352 0.016491890 2647.350 0.008879588 2649.348 0.020513438 2651.346 0.011973243 2653.344 0.010886244 2655.342 0.010855678 2657.340 0.002887021 2659.338 0.008642216 2661.336 0.008296575 2663.334 0.004359746 2665.332 0.006870498 2667.330 0.000951413 2669.328 -0.001814234 2671.326 -0.000829726 2673.324 -0.004146684 2675.322 0.004555271 2677.320 -0.001390834 2679.318 -0.006488533 2681.316 -0.001259408 2683.314 -0.009052479 2685.312 -0.001860057 2687.310 -0.006887639 2689.308 -0.005024874 2691.306 -0.005295109 2693.304 -0.004216787 2695.302 -0.008986205 2697.300 -0.003081649 2699.298 -0.008981380 2701.296 -0.004369115 2703.294 -0.005347686 2705.292 -0.007277224 2707.290 -0.003244244 2709.288 -0.008142979 2711.286 -0.005569903 2713.284 -0.003224474 2715.282 -0.007364419 2717.280 -0.008072556 2719.278 -0.000252745 2721.276 -0.007835941 2723.274 -0.001889744 2725.272 -0.004552790 2727.270 -0.004870987 2729.268 -0.009847011 2731.266 -0.012299929 2733.264 -0.000814017 2735.262 -0.006414081 2737.260 -0.006423603 2739.258 -0.001860053 2741.256 -0.006058367 2743.254 -0.005253753 2745.252 -0.005067452 2747.250 -0.006667235 2749.248 -0.006166637 2751.246 -0.005358866 2753.244 -0.010816781 2755.242 -0.007124901 2757.240 -0.008193652 2759.238 -0.009076313 2761.236 -0.013899798 2763.234 -0.001911209 2765.232 -0.003569677 2767.230 -0.005411791 2769.228 -0.004344355 2771.226 -0.007269555 2773.224 -0.006560936 2775.222 -0.005397162 2777.220 -0.003814548 2779.218 -0.004635734 2781.216 -0.009534185 2783.214 -0.005515566 2785.212 -0.005882620 2787.210 -0.001027268 2789.208 -0.007869920 2791.206 -0.008510904 2793.204 -0.007765150 2795.202 -0.008812242 2797.200 -0.000595937 2799.198 -0.006352239 2801.196 -0.004471680 2803.194 -0.013757478 2805.192 0.000668347 2807.190 -0.009892194 2809.188 -0.003922678 2811.186 -0.003479215 2813.184 -0.005687468 2815.182 -0.011927732 2817.180 -0.007817783 2819.178 -0.006546765 2821.176 -0.004006205 2823.174 -0.000109595 2825.172 -0.004287060 2827.170 -0.005306099 2829.168 -0.006568053 2831.166 -0.006465540 2833.164 0.006650944 2835.162 -0.004925384 2837.160 0.006982107 2839.158 0.001165584 2841.156 -0.001805279 2843.154 0.002308748 2845.152 0.004016430 2847.150 0.003150478 2849.148 0.004788504 2851.146 0.002469372 2853.144 0.010905518 2855.142 0.007783903 2857.140 0.004943119 2859.138 0.010183439 2861.136 0.010257465 2863.134 0.014662962 2865.132 0.019410472 2867.130 0.015557798 2869.128 0.018054970 2871.126 0.019236172 2873.124 0.016808638 2875.122 0.022187714 2877.120 0.021385731 2879.118 0.027077755 2881.116 0.031463169 2883.114 0.031397775 2885.112 0.039001394 2887.110 0.039622325 2889.108 0.031689007 2891.106 0.041997265 2893.104 0.043115076 2895.102 0.045168977 2897.100 0.046615206 2899.098 0.054243695 2901.096 0.054117635 2903.094 0.055272888 2905.092 0.061152928 2907.090 0.067131184 2909.088 0.065597802 2911.086 0.072239637 2913.084 0.077167697 2915.082 0.077019803 2917.080 0.082079656 2919.078 0.087078139 2921.076 0.085266083 2923.074 0.095569007 2925.072 0.092451073 2927.070 0.101765260 2929.068 0.104655303 2931.066 0.109514207 2933.064 0.104997493 2935.062 0.109366551 2937.060 0.114377044 2939.058 0.121654049 2941.056 0.118640795 2943.054 0.119692422 2945.052 0.123541743 2947.050 0.134790853 2949.048 0.120825075 2951.046 0.137056872 2953.044 0.135734230 2955.042 0.145190731 2957.040 0.141854241 2959.038 0.150318742 2961.036 0.161239222 2963.034 0.146097079 2965.032 0.154611975 2967.030 0.162926912 2969.028 0.159404129 2971.026 0.167136207 2973.024 0.170641020 2975.022 0.175584733 2977.020 0.173815787 2979.018 0.193624064 2981.016 0.187841043 2983.014 0.191894248 2985.012 0.189889953 2987.010 0.200877130 2989.008 0.208712876 2991.006 0.208524361 2993.004 0.215183824 2995.002 0.219167888 2997.000 0.230385125