V-FORS Wavelength (nm) %T 1500 85.14582062 1498 84.84659576 1496 83.9454422 1494 82.38260651 1492 80.31614685 1490 77.93000031 1488 75.20632935 1486 72.15299988 1484 69.06266785 1482 66.07555389 1480 62.95996475 1478 60.03909302 1476 57.22245026 1474 54.63136292 1472 52.24343491 1470 49.9526825 1468 47.90003967 1466 46.05545807 1464 44.36426544 1462 42.91498184 1460 41.66532898 1458 40.63182831 1456 39.76731491 1454 39.06716537 1452 38.5803299 1450 38.24334717 1448 38.10855484 1446 38.14801788 1444 38.38237381 1442 38.83293533 1440 39.46205521 1438 40.31904221 1436 41.45688629 1434 42.81906891 1432 44.447258 1430 46.40145111 1428 48.61299515 1426 51.23509216 1424 54.13506699 1422 57.38734055 1420 60.90882874 1418 64.78942871 1416 68.74472809 1414 72.90367889 1412 76.63879395 1410 79.905159 1408 82.45231628 1406 83.83166504 1404 83.87177277 1402 82.66444397 1400 79.83139038 1398 76.11293793 1396 71.84764862 1394 66.69001007 1392 61.72270203 1390 56.89042664 1388 52.26302338 1386 48.0943985 1384 44.26350403 1382 40.64919281 1380 37.53752899 1378 34.89413452 1376 32.56639481 1374 30.61376572 1372 29.02736664 1370 27.61525154 1368 26.56432915 1366 25.70393372 1364 25.08076668 1362 24.76478004 1360 24.56497192 1358 24.67775917 1356 25.01252937 1354 25.652174 1352 26.53670311 1350 27.79262924 1348 29.42512131 1346 31.50794792 1344 34.13125229 1342 37.37172318 1340 41.33596039 1338 46.16455841 1336 51.61445236 1334 57.58610916 1332 63.83140564 1330 69.23361206 1328 72.41505432 1326 72.33885193 1324 68.90828705 1322 62.66629791 1320 54.94403076 1318 47.09540176 1316 40.01039124 1314 33.95640945 1312 29.04515839 1310 25.06720352 1308 21.94300652 1306 19.47363853 1304 17.56951141 1302 16.14670372 1300 15.12147617 1298 14.44487 1296 14.09124851 1294 14.08737564 1292 14.48989201 1290 15.40969944 1288 17.09161186 1286 19.83994102 1284 24.46977997 1282 32.10145569 1280 44.14286804 1278 57.74145126 1276 58.0520401 1274 39.76269913 1272 21.48149109 1270 11.7471056 1268 6.662273407 1266 4.011335373 1264 2.557645082 1262 1.694979191 1260 1.169291258 1258 0.828546763 1256 0.602594316 1254 0.447015792 1252 0.340493292 1250 0.259911954 1248 0.204989225 1246 0.156316623 1244 0.132819608 1242 0.10161148 1240 0.082027659 1238 0.068192706 1236 0.062937699 1234 0.05012529 1232 0.042497583 1230 0.035460964 1228 0.030782994 1226 0.026809001 1224 0.023031868 1222 0.027430585 1220 0.022078222 1218 0.020889621 1216 0.022716068 1214 0.010223798 1212 0.01779544 1210 0.016822107 1208 0.014618049 1206 0.012499016 1204 0.015208153 1202 0.012328278 1200 0.01141498 1198 0.011541872 1196 0.01233568 1194 0.009654281 1192 0.012440822 1190 0.011953451 1188 0.01168112 1186 0.010424552 1184 0.00805391 1182 0.007349281 1180 0.01233076 1178 0.010585977 1176 0.010161691 1174 0.012737608 1172 0.009237584 1170 0.019596288 1168 0.004692459 1166 0.007929273 1164 0.006961339 1162 0.007535271 1160 0.011376841 1158 0.010618483 1156 0.01063831 1154 0.007545579 1152 0.009652697 1150 0.010047806 1148 0.009496655 1146 0.011983905 1144 0.007331522 1142 0.004071328 1140 0.012394946 1138 0.009097258 1136 0.009709666 1134 0.007125464 1132 0.008260131 1130 0.01129186 1128 0.015452039 1126 0.01161844 1124 0.007394291 1122 0.008889797 1120 0.010693244 1118 0.018733136 1116 0.00412881 1114 0.005879832 1112 0.0168065 1110 0.003947502 1108 0.007990456 1106 0.012791159 1104 0.01105208 1102 0.007647752 1100 0.008514022 1098 0.012675405 1096 0.002353404 1094 0.013230925 1092 0.010100793 1090 0.010097955 1088 0.011427918 1086 0.010667792 1084 0.009725768 1082 0.011630311 1080 0.005203908 1078 0.009450159 1076 0.014206559 1074 0.009310446 1072 0.006823269 1070 0.010505767 1068 0.007993395 1066 0.003581313 1064 0.009546262 1062 0.008897605 1060 0.005430351 1058 0.008366221 1056 0.006871413 1054 0.011832828 1052 0.006471933 1050 0.007882135 1048 0.011392022 1046 0.007900748 1044 0.007808888 1042 0.009331288 1040 0.009413161 1038 0.012485525 1036 0.001673278 1034 0.008663772 1032 0.008035885 1030 0.00649629 1028 0.014209599 1026 0.008698022 1024 0.011466275 1022 0.008488109 1020 0.009237234 1018 0.009658795 1016 0.007765177 1014 0.00768707 1012 0.009839594 1010 0.007968836 1008 0.006179863 1006 0.007931352 1004 0.005831609 1002 0.009209485 1000 0.006988659 998 0.007167209 996 0.014074624 994 0.010787723 992 0.00740838 990 0.012908664 988 0.006926779 986 0.007646747 984 0.009434284 982 0.008687674 980 0.004072839 978 0.011584396 976 0.00856026 974 0.007925426 972 0.00876415 970 0.010327234 968 0.008309182 966 0.00808314 964 0.003127708 962 0.009354645 960 0.010151651 958 0.011570728 956 0.008140426 954 0.017619129 952 0.003669097 950 0.008585827 948 0.009124732 946 0.010039015 944 0.008023076 942 0.018672818 940 0.008069506 938 0.007684565 936 0.008281946 934 0.010758761 932 0.010272646 930 0.010293042 928 0.013199875 926 0.009089893 924 0.013652617 922 0.007483359 920 0.013048413 918 0.011908307 916 0.009838598 914 0.011329378 912 0.0104522 910 0.018550325 908 0.011197729 906 0.027041681 904 0.01809541 902 0.010910744 900 0.01042745 898 0.008916784 896 0.01272089 894 0.008616024 892 0.00796605 890 0.0130915 888 0.009826945 886 0.007475963 884 0.009700109 882 0.007597647 880 0.00832102 878 0.014202243 876 0.010035315 874 0.009800433 872 0.007422619 870 0.007634415 868 0.00887977 866 0.009821802 864 0.012430999 862 0.008242739 860 0.012070645 858 0.014286471 856 0.014224136 854 0.009697882 852 0.014079011 850 0.010900106 848 0.007784341 846 0.007993001 844 0.011032987 842 0.007814059 840 0.009200129 838 0.011903785 836 0.005198757 834 0.010558726 832 0.008672972 830 0.011161068 828 -4.83E-05 826 -0.001039414 824 0.002088151 822 -0.000162746 820 -0.000129167 818 -0.000184834 816 0.00039632 814 9.99E-05 812 -5.97E-05 810 -0.000514012 808 1.55E-05 806 0.000280375 804 -0.000451903 802 0.000889132 800 0.001492837 798 -3.76E-05 796 -4.84E-05 794 0.000692661 792 -0.000110625 790 0.000423691 788 0.000823848 786 -0.000711135 784 0.000488359 782 0.000486249 780 0.00175588 778 0.002155392 776 0.005087224 774 0.003690487 772 0.003280715 770 0.001753084 768 0.000488037 766 0.000349187 764 0.001817344 762 0.00115185 760 0.001017953 758 0.001218631 756 0.001082339 754 0.002409731 752 0.001878096 750 0.001876998 748 0.001214444 746 0.001012987 744 0.001146756 742 0.00114604 740 0.001012078 738 0.000880668 736 0.002198842 734 0.000677603 732 0.000481619 730 0.001338166 728 0.000347505 726 0.000744644 724 0.000872893 722 -4.36E-05 720 0.001464295 718 0.000150281 716 0.001791326 714 0.000936671 712 0.001396538 710 0.000478657 708 0.000484067 706 0.000543638 704 0.001068923 702 0.00132628 700 0.001522582 698 0.000738984 696 0.001065693 694 0.001715134 692 0.00190891 690 0.000803962 688 0.0008035 686 0.00145302 684 0.001840504 682 0.002682172 680 0.003204274 678 0.00306675 676 0.002614005 674 0.003131565 672 0.004219668 670 0.005190766 668 0.005580847 666 0.005699672 664 0.007255551 662 0.008717036 660 0.010804665 658 0.012867026 656 0.016489558 654 0.020968147 652 0.028495878 650 0.039146338 648 0.055934563 646 0.07725697 644 0.108455747 642 0.154237911 640 0.221237406 638 0.319339246 636 0.464324325 634 0.695483863 632 1.076113343 630 1.742112875 628 2.93792057 626 5.173256397 624 9.51820755 622 17.57900429 620 30.85845757 618 48.2254982 616 63.61830902 614 74.13074493 612 80.8553009 610 85.24187469 608 88.17643738 606 89.98878479 604 91.07466125 602 91.71705627 600 92.0353775 598 92.01303864 596 91.74438477 594 91.29262543 592 91.14904785 590 91.33460999 588 91.91909027 586 92.7179718 584 93.38876343 582 93.89733887 580 94.18973541 578 94.39405823 576 94.54052734 574 94.57820129 572 94.33678436 570 93.81565857 568 93.01338196 566 92.08008575 564 91.39683533 562 91.00648499 560 90.96147919 558 91.08210754 556 91.28769684 554 91.52962494 552 91.79737091 550 92.10253906 548 92.54769897 546 92.88277435 544 93.06822968 542 92.90242004 540 92.46118164 538 91.9588089 536 91.81179047 534 91.97884369 532 92.39395142 530 92.54650879 528 92.19618225 526 91.40631866 524 90.4961319 522 89.82684326 520 89.30182648 518 88.72364807 516 87.95514679 514 87.30038452 512 86.85923004 510 86.5668335 508 85.50502014 506 83.0195694 504 79.36814117 502 75.22836304 500 70.66152191 498 64.66642761 496 56.62495041 494 46.47592545 492 35.44393158 490 24.28658867 488 14.38047123 486 7.149118423 484 3.042060137 482 1.114785194 480 0.361824006 478 0.107653663 476 0.032251105 474 0.010355011 472 0.00398096 470 0.002404992 468 0.000701363 466 0.001205377 464 0.001834972 462 0.000889555 460 0.000195055 458 0.000446576 456 0.000511608 454 0.000576053 452 0.001141244 450 0.001391973 448 0.000446651 446 0.001330212 444 0.001769635 442 0.000698471 440 0.000635733 438 0.000634787 436 0.001073492 434 0.001262218 432 0.001578196 430 0.000944755 428 0.001577398 426 0.000436308 424 0.001071396 422 0.001322242 420 0.000113908 418 0.000942115 416 0.000817011 414 0.000938779 412 0.001192313 410 0.000558511 408 -7.82E-05 406 -0.000210356 404 0.000554341 402 0.000485387 400 0.000170534 398 0.000427264 396 0.000109227 394 0.00118595 392 0.000299764 390 0.000237681 388 -0.000395509 386 -0.000765751 384 0.000121873 382 -0.000382957 380 -0.000255533 378 0.000183894 376 -0.000633089 374 0.000237788 372 0.000637267 370 -0.000449781 368 0.001547464 366 -0.000291215 364 -0.000312598 362 0.00060227 360 0.000813873 358 0.000766968 356 -0.000192714 354 0.000656119 352 -0.000217948 350 0.001499176 348 -0.000119107 346 -0.000271282 344 -0.000773682 342 -0.000140604 340 -0.000921985 338 -0.000904424 336 0.000938598 334 -0.001533074 332 -0.001786704 330 0.000327314 328 -0.001400126 326 0.000879252 324 -0.006119586 322 -0.006678559 320 -0.002675415 318 -0.003004248 316 -0.003718191 314 -0.004148252 312 -0.003796589 310 -0.005634533 308 -0.011265712 306 -0.011960627 304 -0.006736542 302 -0.008259102 300 0.000904792