[page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
PIONIER trending system: FULL report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T22:40:08 (UT)
  | now: 2024-11-21T23:07:00 (UT) muc05 QC pipeline: pioni-3.9.6 (installed 2023-06-22)
close window history: 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023   2024   HEALTH FULL
  ... ... ... ... ... ... ... ... ...
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB none   NONE VAL0,2 30871 tfvis12_avg all (full time range) TF^2 High sensitivity Baseline12
2 QC1DB none   NONE VAL0,2 30791 tfvis13_avg all (full time range) Baseline 13
3 QC1DB none   NONE VAL0,2 30423 tfvis14_avg all (full time range) Bas1eline 4
4 QC1DB none   NONE VAL0,2 30722 tfvis23_avg all (full time range) Bas2eline 3
5 QC1DB none   NONE VAL0,2 30372 tfvis24_avg all (full time range) Bas2eline 4
6 QC1DB none   NONE VAL0,2 30440 tfvis34_avg all (full time range) Bas3eline 4

*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis12_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30871
[click plot for closeup]
Plot 2
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis13_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30791
[click plot for closeup]
Plot 3
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis14_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30423
[click plot for closeup]
Plot 4
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis23_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30722
[click plot for closeup]
Plot 5
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis24_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30372
[click plot for closeup]
Plot 6
scores: not implemented
data source:pionier_fringe
(QC1 database)
dataset:tfvis34_avg
average:none
fixed thresholds:0...2NONE
N_data plotted:30440
[click plot for closeup]
This plot

This is the trending plot using PIONIER QC parameters derived from CALIB_FRINGE frames.

The pipeline calculates the TF using the diameter of the object extracted from the faint calibrator catalog (if found)
. Each of the plot represent the TF^2 measured on one baseline.
For the ATs, the scatter of the measured TF^2 could come from the atmosphere or from the fact that the telescope positioned on a given station (1,2,3 or 4) could be different (AT1,2,3 or 4) and the baseline length can also be very different
. An outlier could come from a wrong diameter in the calibrator catalog.
This information is given in the "data Download" link.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up