mirror sites: PL (internal link) HQ     [?]

Health Check monitor

 

CAL | HC | refs | QC
HealthCheck Monitor
   HOME | UsersGuide
  sl icon ALL INSTRUMENTS
 
all KPI reports
GRAVITY:
P2VM avg
Other HC:
QC links:
        [page auto-refreshes after 300 sec]   [stop | on]            [press Ctrl+Shift+R to enforce refresh of scores, dates and news]
GRAVITY trending system: HEALTH CHECK report
HELP USERS-GUIDE MORE
Last update: 2024-11-21T18:31:05 (UT)
  | now: 2024-11-21T21:30:43 (UT) muc05 QC pipeline: gravity-1.5.4 (installed 2022-03-24)
same group: coherence phase
General news: NOTE: The Health Check and calChecker services are moved to qcFlow on an instrument by instrument basis. The current pages will not be updated any longer once the move has been finished.
GRAVITY news:  
Report news:
DATE*: [?] 2024-11-14
report | NLT
2024-11-15
report | NLT
2024-11-16
report | NLT
2024-11-17
report | NLT
2024-11-18
report | NLT
2024-11-19
report | NLT
2024-11-20
report | NLT
2024-11-21
no data | NLT
r...
Raw CAL displays:
raw raw raw raw raw raw raw no CAL raw files
P...
CAL product quality:
products products products products products products products no CAL products
 
transfer   ngas [?]

scores&comments | history ... | plot tutorial ... | contact | HC_docu... | quality events...                 daily/often; important to check     [?]
*Date on this monitor changes at 21:00 UT
png: Information and research:
- png file - advanced studies: QC1 browser | QC1 plotter
Plot
?
Symb
?
Source
*
Average ? Thresholds ? N_
data
QC1
parameter
Data
downloads
Remarks
method value unit method value
1 QC1DB MEDIAN 0.0193 none VAL0.018,0.022 5 phaserms_sc this | last_yr | all average phase RMS of P2VM, LOW resolution, SPLIT polarisation, Science Camera (SC) detector
2 QC1DB MEDIAN 0.0193 none VAL0.017,0.021 103 phaserms_sc this | last_yr | all average phase RMS of P2VM, MEDIUM resolution, SPLIT polarisation, Science Camera (SC) detector
3 QC1DB MEDIAN 0.0168 none VAL0.016,0.020 17 phaserms_sc this | last_yr | all average phase RMS of P2VM, HIGH resolution, SPLIT polarisation, Science Camera (SC) detector
4 QC1DB MEDIAN 0.0197 none VAL0.0145,0.026 125 phaserms_ft this | last_yr | all average phase RMS of P2VM, SPLIT polarisation, Fringe Tracker (FT) detector
5 QC1DB MEDIAN 0.0185 none VAL0.016,0.020 3 phaserms_sc this | last_yr | all average phase RMS of P2VM, LOW resolution, COMBINED polarisation, Science Camera (SC) detector
6 QC1DB MEDIAN 0.018 none VAL0.015,0.019 66 phaserms_sc this | last_yr | all average phase RMS of P2VM, MEDIUM resolution, COMBINED polarisation, Science Camera (SC) detector
7 QC1DB MEDIAN 0.0152 none VAL0.0140,0.0180 35 phaserms_sc this | last_yr | all average phase RMS of P2VM, HIGH resolution, COMBINED polarisation, Science Camera (SC) detector
8 QC1DB MEDIAN 0.0178 none VAL0.0135,0.025 104 phaserms_ft this | last_yr | all average phase RMS of P2VM, COMBINED polarisation, Fringe Tracker (FT) detector
*Data sources: QC1DB: QC1 database; LOCAL: local data source
Plot 1
scores: not implemented
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.0193none
fixed thresholds:0.018...0.022none
N_data plotted:5
[click plot for closeup]
Plot 2
scores: 8|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.0193none
fixed thresholds:0.017...0.021none
N_data plotted:103
[click plot for closeup]
Plot 3
scores: 2|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.0168none
fixed thresholds:0.016...0.02none
N_data plotted:17
[click plot for closeup]
Plot 4
scores: 10|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_ft
median:0.0197none
fixed thresholds:0.0145...0.026none
N_data plotted:125
[click plot for closeup]
Plot 5
scores: not implemented
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.0185none
fixed thresholds:0.016...0.02none
N_data plotted:3
[click plot for closeup]
Plot 6
scores: 10|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.018none
fixed thresholds:0.015...0.019none
N_data plotted:66
[click plot for closeup]
Plot 7
scores: 1|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_sc
median:0.0152none
fixed thresholds:0.014...0.018none
N_data plotted:35
[click plot for closeup]
Plot 8
scores: 11|
data source:gravity_p2vm
(QC1 database)
dataset:phaserms_ft
median:0.0178none
fixed thresholds:0.0135...0.025none
N_data plotted:104
[click plot for closeup]
This plot

Trending plots for pixel-to-visibility-maxtrix (P2VM) calibrations. This plot contains values that are averaged over the six baselines.

Note about LOW resolution: with pipeline version 1.2.x, installed 2019-03-25 for QC, some QC parameters for P2VM do not give meaningful values. This includes the phase RMS. Plotting of these parameters and scoring has therefore been stopped for LOW resolution.  


General information

Click on any of the plots to see a close-up version.

The latest date is indicated on top of the plot.

If configured,

  • data points belonging to the latest date are specially marked
  • statistical averages are indicated by a solid line, and thresholds by broken lines
  • outliers are marked by a red asterisk. They are defined as data points outside the threshold lines
  • "aliens" (= data points outside the plot Y limits) are marked by a red arrow ( or )
  • you can download the data for each parameter set if the 'Data downloads' link shows up