Source RA DEC Sp.type Mv SiC PAH1_1 PAH1 ARIII SIV_1 SIV PAH2_1 SIV_2 PAH2 PAH2_2 NEII_1 NEII NEII_2 Q0 QH2 Q1 Q2 Q3 Q4 Q7 Q8 Error HD787 00 12 10.001 -17 56 18.27 K5III 6.789 6.831956 11.824595 11.191833 10.484695 8.958070 8.422745 8.104236 7.693360 7.470664 6.440308 6.072942 5.799441 5.593805 3.449533 3.223564 3.026793 2.715777 2.516403 2.323350 1.831537 1.622872 .1563E+01 HD2261 00 26 17.030 -42 18 21.81 K0IIIb 3.46 36.911983 72.854836 67.521049 61.805027 50.112022 46.236893 44.178082 41.570732 40.294868 34.777550 32.506790 31.458490 30.469917 18.934811 17.721991 16.620279 14.838363 13.625014 12.471920 9.791168 8.691337 .1820E+01 HD2436 00 28 12.706 +16 26 42.16 K5III 7.673 4.280034 7.407495 7.011827 6.568621 5.612064 5.276517 5.076979 4.819998 4.680355 4.034476 3.804296 3.633313 3.504598 2.161049 2.019183 1.896224 1.701513 1.576461 1.456008 1.147210 1.016769 .1762E+01 HD4301 00 45 24.107 -04 37 45.02 M0III 7.82 5.070732 8.501562 8.094350 7.562957 6.681252 6.255168 6.011337 5.667986 5.517640 4.793167 4.512104 4.308905 4.161227 2.597251 2.431749 2.281462 2.037893 1.871874 1.714523 1.347212 1.196361 .1824E+01 HD4815 00 48 35.395 -74 55 24.25 K5III 6.480 5.195508 8.992176 8.511288 7.972777 6.813004 6.404991 6.163033 5.850749 5.681210 4.897743 4.618165 4.410594 4.254318 2.623265 2.451451 2.301858 2.065233 1.913914 1.766614 1.392706 1.234288 .1793E+01 HD5112 00 53 00.498 -01 08 39.47 M0III 6.369 13.286586 22.274078 21.207470 19.815819 17.504230 16.387604 15.749563 14.851631 14.459037 12.558099 11.822621 11.290112 10.901571 6.804636 6.370966 5.977649 5.339543 4.904193 4.491888 3.529584 3.134713 .1645E+01 HD8498 01 23 30.965 -30 56 44.27 M0III 7.465 6.851718 11.487659 10.937400 10.219613 9.027673 8.452151 8.122718 7.658363 7.455937 6.476855 6.096184 5.822240 5.622648 3.509415 3.285602 3.082849 2.753604 2.529363 2.316774 1.820142 1.616555 .1819E+01 HD9362 01 31 15.120 -49 04 21.77 K0IIIb 4.94 6.722136 13.269764 12.297048 11.256824 9.126513 8.422260 8.046107 7.570817 7.338533 6.334242 5.919255 5.727669 5.548996 3.448109 3.227440 3.027206 2.702170 2.481001 2.271452 1.783216 1.582776 .1560E+01 HD9692 01 34 23.461 -28 14 12.35 M0III 8.584 3.557048 5.981514 5.638371 5.238057 4.628403 4.344520 4.182911 3.957396 3.856539 3.372292 3.185659 3.047627 2.945157 1.841594 1.724589 1.618595 1.446196 1.328844 1.217240 0.956887 0.849878 .1862E+01 HD12524 02 01 42.382 -44 42 48.80 K5III 6.668 8.272772 14.317715 13.552421 12.696364 10.847492 10.198861 9.813667 9.316853 9.046876 7.798255 7.353730 7.022218 6.774527 4.176915 3.903632 3.665158 3.288639 3.046971 2.813290 2.218043 1.965334 .1819E+01 HD16815 02 40 40.038 -39 51 19.54 K0.5IIIb 5.119 6.368299 12.571126 11.650072 10.664122 8.647069 7.977988 7.621900 7.172380 6.951605 6.001102 5.609127 5.426806 5.257113 3.266809 3.057702 2.867819 2.560026 2.350483 2.151875 1.689385 1.499471 .1612E+01 HD20356 03 16 21.692 -05 43 49.56 K5III 7.950 3.714571 6.453330 6.031061 5.609149 4.795314 4.522913 4.362013 4.158173 4.042510 3.515076 3.329028 3.186536 3.076529 1.901271 1.777240 1.669236 1.498503 1.388684 1.282758 1.011600 0.896749 .1828E+01 HD20644 03 20 20.358 +29 02 54.42 K3IIIa 6.076 3.841937 7.160685 6.475578 5.875835 4.995653 4.648911 4.471329 4.270268 4.157887 3.654261 3.478905 3.338683 3.229379 2.007578 1.882761 1.780082 1.618459 1.494541 1.356338 1.067588 0.948004 .1717E+01 HD22663 03 37 05.679 -40 16 28.80 K1III 5.606 4.627031 8.548712 7.960620 7.344661 6.235854 5.760407 5.510735 5.213708 5.062703 4.362735 4.112012 3.925928 3.789428 2.343351 2.196111 2.074743 1.884861 1.739052 1.577436 1.240086 1.100695 .1766E+01 HD25165 03 59 30.113 -12 34 28.02 K5III 7.114 4.552301 7.878237 7.456930 6.985489 5.969574 5.611831 5.399887 5.126978 4.977908 4.291245 4.046404 3.864476 3.727435 2.298381 2.147898 2.016714 1.809628 1.677088 1.548256 1.220319 1.081341 .1598E+01 HD26967 04 14 00.126 -42 17 40.00 K2III 4.96 9.271627 17.130552 15.952045 14.717851 12.495332 11.544184 11.043064 10.447046 10.145082 8.741260 8.239719 7.867121 7.594644 4.695636 4.400416 4.157521 3.777342 3.484831 3.160944 2.485072 2.205937 .1536E+01 HD33554 05 11 41.566 +16 02 44.35 K5III 6.744 7.826463 13.545080 12.820497 12.010561 10.261758 9.648303 9.284043 8.813573 8.558531 7.378228 6.956264 6.643621 6.407885 3.951561 3.692622 3.467073 3.111028 2.882823 2.661499 2.097812 1.859102 .1747E+01 HD35536 05 25 01.742 -10 19 44.43 K5III 7.180 5.367764 9.289384 8.793245 8.237951 7.037854 6.617277 6.367259 6.044315 5.869535 5.059825 4.771102 4.556655 4.395164 2.709827 2.532247 2.377847 2.133519 1.977108 1.825615 1.438852 1.275101 .1947E+01 HD37984 05 42 28.626 +01 28 28.57 K1III 6.069 4.483430 8.283626 7.714141 7.116510 6.043355 5.581172 5.339580 5.050646 4.905382 4.227325 3.984369 3.804041 3.671710 2.270502 2.127750 2.010412 1.826363 1.685044 1.528359 1.201632 1.066561 .1665E+01 HD39425 05 50 57.594 -35 46 06.19 K1.5III 4.28 19.333567 35.718884 33.265995 30.682158 26.057705 24.073551 23.027504 21.784004 21.154642 18.229242 17.180872 16.403763 15.834682 9.793167 9.175910 8.669263 7.876366 7.266655 6.591362 5.181507 4.599529 .1884E+01 HD41047 06 01 16.306 -33 54 42.72 K5III 7.148 6.584916 11.397057 10.787503 10.104674 8.634223 8.118567 7.811140 7.415260 7.200761 6.207559 5.853304 5.590439 5.391940 3.324532 3.106595 2.917322 2.617508 2.425848 2.239115 1.765236 1.564186 .1793E+01 HD49293 06 47 51.640 +02 24 43.65 K0+IIIa 5.597 4.867956 9.609370 8.905034 8.150846 6.608359 6.098732 5.826349 5.482867 5.314088 4.586552 4.286744 4.148388 4.018399 2.497105 2.337247 2.192105 1.956752 1.796682 1.644919 1.291248 1.146157 .1990E+01 HD49968 06 51 59.994 +23 36 05.96 K5III 7.184 4.003648 6.929755 6.558320 6.143903 5.249485 4.935606 4.749257 4.508593 4.377900 3.774022 3.558676 3.398622 3.278201 2.021345 1.888926 1.773614 1.591629 1.474563 1.361555 1.073128 0.951047 .1613E+01 HD61935 07 41 14.835 -09 33 04.19 K0III 4.95 6.938259 13.696497 12.693023 11.618176 9.419907 8.692388 8.304434 7.814844 7.574175 6.537724 6.109018 5.914429 5.727024 3.559177 3.331264 3.124487 2.789236 2.560533 2.344230 1.840416 1.633714 .1516E+01 HD71095 08 25 35.537 +02 06 08.20 K5III 7.280 4.314729 7.467733 7.068430 6.621544 5.657555 5.319056 5.118316 4.858909 4.718133 4.067250 3.835235 3.662909 3.532966 2.178307 2.035767 1.911523 1.714994 1.589257 1.467253 1.156580 1.025008 .1758E+01 HD75691 08 50 31.935 -27 42 35.59 K2.5III 5.311 11.440100 20.460875 19.007429 17.842104 15.616329 14.500580 13.708345 12.842254 12.483956 10.794610 10.167855 9.708447 9.374856 5.841922 5.469322 5.131075 4.582011 4.208260 3.853876 3.027199 2.687644 .1781E+01 HD76110 08 52 48.074 -38 43 27.17 M0III 7.367 6.828215 11.447329 10.898786 10.183830 8.994996 8.420770 8.093731 7.632678 7.430624 6.454216 6.075359 5.801898 5.602962 3.497052 3.274166 3.072009 2.743927 2.520377 2.308474 1.814156 1.610906 .1781E+01 HD79554 09 15 13.842 +14 56 29.32 K1III 6.699 3.896854 7.239312 6.620018 6.044690 5.135709 4.767610 4.575135 4.352385 4.234402 3.694735 3.504141 3.356278 3.243868 2.012334 1.886996 1.783563 1.621605 1.496470 1.357958 1.068385 0.948554 .1734E+01 HD81420 09 25 24.032 -05 07 02.80 K5III 7.138 5.027909 8.701504 8.236575 7.716072 6.592353 6.198230 5.964071 5.661921 5.497793 4.739485 4.469090 4.268184 4.116947 2.538437 2.372179 2.227653 1.998607 1.852010 1.709795 1.347708 1.194292 .1602E+01 HD82660 09 32 55.774 -13 31 00.58 K5III 7.482 3.619972 6.264466 5.930221 5.555636 4.746398 4.462579 4.293996 4.076894 3.958576 3.412312 3.217647 3.073025 2.964107 1.827401 1.708225 1.603598 1.438990 1.333373 1.231075 0.970314 0.859966 .1835E+01 HD83425 09 38 27.295 +04 38 57.32 K3III 6.032 7.951490 14.220880 13.211325 12.402008 10.854229 10.079247 9.527927 8.925599 8.677136 7.502213 7.067246 6.747457 6.516357 4.060356 3.801399 3.566253 3.184743 2.924624 2.678594 2.103957 1.868065 .1652E+01 HD89682 10 19 36.755 -55 01 45.60 K3II 6.213 11.433428 20.448076 18.996012 17.831394 15.607631 14.489589 13.699211 12.834480 12.477167 10.787905 10.160759 9.702991 9.369202 5.838787 5.466324 5.128081 4.579451 4.205718 3.851570 3.025430 2.686066 .1809E+01 HD93813 10 49 37.494 -16 11 37.26 K1.5IIIb 4.36 25.365217 46.867195 43.640640 40.267830 34.183952 31.583439 30.210533 28.579586 27.754110 23.917269 22.541367 21.522156 20.774302 12.846258 12.037741 11.372758 10.333696 9.533647 8.647593 6.798127 6.034228 .1537E+01 HD95272 10 59 46.470 -18 17 55.65 K0+III 5.17 6.953185 13.724231 12.719376 11.642562 9.439977 8.709484 8.320709 7.829986 7.590036 6.551811 6.124626 5.925374 5.739554 3.566433 3.338207 3.130978 2.795038 2.565935 2.349430 1.844452 1.637098 .1798E+01 HD95314 11 00 11.715 -14 05 00.13 K5III 7.387 3.985252 6.896831 6.528769 6.116825 5.225411 4.912689 4.727114 4.488057 4.358106 3.756660 3.542227 3.383046 3.263190 2.012121 1.880562 1.765509 1.584070 1.467713 1.355283 1.068266 0.946640 .1833E+01 HD98118 11 17 17.403 +02 00 37.95 M0III 6.719 9.647749 16.175514 15.400157 14.390513 12.710786 11.899303 11.436178 10.783750 10.498274 9.119710 8.585364 8.198276 7.916247 4.941376 4.626289 4.340649 3.877323 3.561167 3.262132 2.563260 2.276241 .1649E+01 HD99167 11 24 36.644 -10 51 34.00 K5III 6.398 13.739602 23.774794 22.507380 21.085714 18.014658 16.938623 16.297859 15.472239 15.024477 12.952159 12.211736 11.663129 11.249277 6.936598 6.482410 6.086818 5.461614 5.060757 4.672925 3.682880 3.264531 .1597E+01 HD99998 11 30 18.900 -03 00 12.57 K3.5III 4.771 10.502131 18.782606 17.449276 16.379539 14.335582 13.311559 12.584264 11.789803 11.460445 9.909359 9.332810 8.912784 8.605881 5.363046 5.020965 4.710335 4.206284 3.863124 3.537606 2.778987 2.467454 .1830E+01 HD108381 12 26 56.271 +28 16 06.34 K1III 5.486 5.589896 10.328042 9.617192 8.873164 7.533526 6.959792 6.657361 6.297437 6.116047 5.271203 4.967644 4.743050 4.577950 2.831098 2.653125 2.506438 2.277460 2.101314 1.905630 1.498217 1.329784 .1722E+01 HD110458 12 42 35.465 -48 48 47.12 K0III 5.760 3.860430 7.620767 7.061889 6.464736 5.241381 4.836587 4.620578 4.348545 4.214486 3.637228 3.399604 3.289787 3.186758 1.980249 1.853297 1.738340 1.551734 1.424705 1.304339 1.024011 0.908959 .1571E+01 HD111067 12 46 38.757 +16 34 38.98 K3III 6.489 4.813394 8.608947 7.997637 7.507877 6.571008 6.100558 5.767421 5.404119 5.252671 4.541633 4.277744 4.084620 3.944468 2.458078 2.301185 2.158770 1.927812 1.770672 1.621627 1.273610 1.130804 .1726E+01 HD111915 12 53 06.913 -48 56 36.26 K3.5III 5.723 10.068778 18.007620 16.729660 15.703686 13.745296 12.760938 12.064239 11.301780 10.987347 9.500572 8.947989 8.543949 8.251629 5.141909 4.813991 4.516176 4.032888 3.703723 3.391731 2.664398 2.365537 .1847E+01 HD114326 13 09 47.837 +16 50 55.04 K5III 7.405 3.641165 6.301440 5.964829 5.587870 4.773826 4.489149 4.319271 4.100846 3.981801 3.432334 3.236476 3.090995 2.981372 1.838083 1.718010 1.613179 1.447191 1.340998 1.238230 0.976061 0.865013 .1763E+01 HD115478 13 17 15.606 +13 40 32.27 K3III 6.664 3.702035 6.621400 6.151118 5.774261 5.054123 4.692085 4.435840 4.155341 4.039755 3.493093 3.290131 3.141676 3.033784 1.890742 1.770118 1.660290 1.482643 1.361691 1.247095 0.979582 0.869732 .1757E+01 HD119193 13 42 54.692 -50 47 24.85 M0III 8.124 4.647301 7.817646 7.362128 6.836554 6.041499 5.671370 5.461817 5.167902 5.036681 4.407400 4.164597 3.984722 3.851335 2.408403 2.255495 2.116747 1.891580 1.737724 1.592075 1.251623 1.111672 .1800E+01 HD123123 14 06 22.300 -26 40 56.52 K2-III 4.383 17.105806 31.603928 29.429689 27.151791 23.054306 21.299719 20.374140 19.272772 18.716211 16.128637 15.202572 14.512581 14.009330 8.662706 8.118249 7.670189 6.968870 6.429201 5.831784 4.584802 4.069273 .1585E+01 HD124294 14 12 53.752 -10 16 25.44 K2.5III 5.537 12.494118 22.346487 20.758753 19.486349 17.055285 15.835930 14.970723 14.024447 13.634068 11.788935 11.104471 10.601620 10.239474 6.380482 5.973432 5.603781 5.004368 4.595971 4.209078 3.305781 2.935394 .1534E+01 HD126927 14 28 41.720 -06 54 01.81 K5III 6.939 5.749709 9.950756 9.418416 8.823525 7.537861 7.088737 6.820628 6.475557 6.287378 5.419709 5.110703 4.880841 4.708021 2.902949 2.712906 2.547226 2.285415 2.117800 1.955351 1.541135 1.365764 .1769E+01 HD130157 14 47 13.653 -21 19 29.50 K5III 7.741 4.670461 8.113753 7.582603 7.052536 6.029055 5.685991 5.484369 5.228478 5.082891 4.419575 4.185630 4.006611 3.868258 2.390423 2.234550 2.098955 1.884392 1.746210 1.613160 1.271948 1.127347 .1795E+01 HD133550 15 06 13.965 -36 15 52.42 K5-III 7.983 4.544245 7.894800 7.377372 6.861678 5.865075 5.533062 5.336335 5.087678 4.945834 4.300012 4.072454 3.898110 3.763522 2.325686 2.174345 2.042044 1.833380 1.698869 1.569302 1.237471 1.096972 .1820E+01 HD133774 15 06 37.610 -16 15 24.67 K5III 6.808 8.729524 15.107976 14.300887 13.397177 11.446405 10.761955 10.355000 9.831132 9.546043 8.228987 7.758897 7.410252 7.147594 4.407293 4.118597 3.867362 3.469958 3.215193 2.968890 2.340028 2.074335 .1594E+01 HD136028 15 18 26.154 -00 27 40.58 K5III 7.421 3.774263 6.531632 6.182875 5.792191 4.948470 4.652896 4.476916 4.250389 4.127246 3.557754 3.354824 3.203991 3.090479 1.905652 1.780698 1.672322 1.500116 1.389955 1.283580 1.011688 0.896570 .1956E+01 HD137744 15 28 15.411 -16 42 59.43 K4.5III 7.213 5.343094 9.247780 8.753316 8.200101 7.006268 6.587207 6.338144 6.017688 5.842730 5.036180 4.749316 4.535747 4.375221 2.697863 2.520954 2.367224 2.123771 1.968124 1.817095 1.432222 1.269270 .1797E+01 HD139663 15 40 16.903 -23 49 05.13 K3-III 6.307 4.835632 8.648267 8.034850 7.540876 6.602068 6.129872 5.794530 5.428733 5.276754 4.562706 4.297500 4.103509 3.962939 2.469422 2.311811 2.168824 1.936935 1.778570 1.628825 1.279506 1.136088 .1550E+01 HD145892 16 13 15.441 +05 01 15.76 K5III 6.969 4.962176 8.588450 8.129186 7.615759 6.506111 6.117884 5.886349 5.588448 5.426120 4.677589 4.410796 4.212494 4.063238 2.505017 2.341271 2.198519 1.972715 1.827780 1.687811 1.330117 1.178806 .1650E+01 HD145897 16 13 50.904 -11 50 16.02 K3III 6.654 4.966525 8.909384 8.194478 7.648677 6.698065 6.234263 5.904425 5.548169 5.399337 4.700669 4.442758 4.249543 4.106753 2.563884 2.400695 2.252797 2.012447 1.848704 1.693344 1.330643 1.181623 .1739E+01 HD149009 16 31 13.465 +22 11 43.41 K5III 7.426 5.989592 10.394754 9.749924 9.085810 7.765810 7.318779 7.054475 6.716669 6.527133 5.660960 5.354591 5.122810 4.944617 3.053704 2.854413 2.680593 2.406243 2.230194 2.058862 1.624144 1.439318 .1666E+01 HD156277 17 21 59.449 -67 46 14.18 K2-III 5.99 5.171053 9.553997 8.896729 8.208032 6.969124 6.439007 6.159129 5.826117 5.657829 4.875953 4.595387 4.387457 4.234999 2.618672 2.454212 2.318778 2.106759 1.943570 1.762872 1.385918 1.230124 .1576E+01 HD161096 17 43 28.358 +04 34 02.26 K2III 3.967 26.054321 48.135941 44.822803 41.353527 35.120193 32.441265 31.031666 29.356609 28.508490 24.566381 23.153416 22.107023 21.337368 13.196575 12.366363 11.683746 10.614315 9.792764 8.882450 6.982997 6.198110 .1556E+01 HD163376 17 57 47.848 -41 42 58.79 M0III 6.578 18.099468 30.431061 28.709576 26.685108 23.579292 22.126085 21.300943 20.145067 19.629665 17.154444 16.199575 15.494516 14.974448 9.360815 8.766641 8.226990 7.350977 6.753158 6.186735 4.863234 4.319368 .1585E+01 HD169916 18 27 58.246 -25 25 18.15 K1IIIb 3.888 21.836851 40.346130 37.572411 34.666687 29.430670 27.188143 26.007723 24.604465 23.893967 20.589499 19.405998 18.527985 17.885098 11.056744 10.364369 9.792052 8.896196 8.207271 7.444767 5.852720 5.194685 .1688E+01 HD173780 18 46 04.481 +26 39 43.62 K2III 6.036 4.607654 8.513383 7.927415 7.313918 6.210138 5.737288 5.488228 5.191337 5.041052 4.344508 4.094751 3.909567 3.773556 2.333331 2.186741 2.066071 1.876956 1.731685 1.570784 1.234907 1.096094 .1642E+01 HD174387 18 52 27.255 -46 35 42.25 M0III 7.167 8.888266 14.935414 14.115729 13.135334 11.606158 10.885074 10.475886 9.901578 9.646347 8.419409 7.945455 7.597659 7.343293 4.588250 4.296682 4.031928 3.602542 3.309179 3.031472 2.382901 2.116248 .1802E+01 HD177716 19 06 56.415 -27 40 13.57 K1.5IIIb 4.51 18.771360 34.683468 32.298164 29.793213 25.298805 23.373522 22.357611 21.149920 20.539042 17.699558 16.682434 15.927925 15.374084 9.505929 8.909146 8.417109 7.647491 7.055583 6.399535 5.030892 4.465301 .1658E+01 HD178345 19 10 01.801 -39 20 26.81 K0II 5.315 7.830547 15.458136 14.324814 13.112244 10.630948 9.809540 9.371943 8.819057 8.548061 7.378964 6.897165 6.672314 6.463775 4.016784 3.759717 3.526318 3.147898 2.889960 2.646019 2.077647 1.843759 .1580E+01 HD187150 19 48 50.251 -12 19 09.55 K5III 8.214 4.011048 6.964540 6.520703 6.070175 5.189351 4.892493 4.717242 4.492946 4.367826 3.793564 3.590606 3.435812 3.316689 2.049285 1.915801 1.798877 1.614852 1.496680 1.381846 1.089925 0.966114 .1825E+01 HD187660 19 51 11.110 -02 27 39.57 K5III 7.72 3.602255 6.234509 5.900751 5.528557 4.723591 4.441106 4.273099 4.056917 3.939188 3.395550 3.201835 3.057935 2.949569 1.818454 1.699903 1.596050 1.431828 1.326931 1.224996 0.965541 0.855757 .1709E+01 HD188114 19 55 15.691 -41 52 06.05 K0II-III 5.204 7.233573 14.278651 13.232401 12.113302 9.820026 9.061353 8.657647 8.146501 7.895738 6.815048 6.371659 6.164440 5.972824 3.710360 3.472959 3.257391 2.907859 2.669870 2.444030 1.918572 1.703200 .1583E+01 HD188603 19 56 56.810 -27 10 11.61 K2.5IIb 6.026 9.962668 17.890375 16.396723 15.273000 13.376363 12.459485 11.809778 11.113109 10.817061 9.439228 8.930165 8.548033 8.263317 5.161951 4.834459 4.536851 4.053194 3.723568 3.411088 2.680727 2.380703 .1851E+01 HD189695 20 00 58.992 +08 33 27.90 K5III 7.474 4.346833 7.522913 7.120453 6.670165 5.699626 5.358887 5.156382 4.895401 4.753548 4.097322 3.863528 3.689886 3.559114 2.194561 2.050946 1.925532 1.727815 1.600691 1.478027 1.165067 1.032475 .1868E+01 HD189831 20 03 33.450 -37 56 26.79 K5III 6.214 8.295775 14.357736 13.589751 12.730371 10.877714 10.227416 9.840526 9.342459 9.071535 7.819811 7.373045 7.043214 6.792955 4.188601 3.913948 3.675207 3.297844 3.055610 2.821267 2.224229 1.970726 .1570E+01 HD196321 20 36 43.641 -02 32 59.65 K5II 6.534 11.512939 19.925512 18.860180 17.667509 15.095031 14.194667 13.656830 12.964787 12.589490 10.852691 10.233084 9.773254 9.427329 5.812928 5.432199 5.100422 4.576388 4.240427 3.914872 3.086156 2.734119 .1782E+01 HD198048 20 49 28.971 -46 13 36.82 K5III 6.451 10.074402 17.435877 16.503971 15.460142 13.209887 12.420932 11.950868 11.345704 11.016526 9.496347 8.954675 8.551319 8.249636 5.086460 4.753124 4.463288 4.004725 3.710612 3.426320 2.700722 2.394013 .1805E+01 HD199697 20 58 16.351 +22 19 33.27 K3.5III 6.745 4.763437 8.518535 7.914260 7.429841 6.502854 6.036555 5.707542 5.347147 5.197675 4.494437 4.233352 4.042223 3.903535 2.432595 2.277273 2.136436 1.907624 1.752036 1.604536 1.260350 1.119068 .1677E+01 HD211416 22 18 30.099 -60 15 34.59 K3III 4.25 40.985882 73.300720 68.095009 63.923294 55.952515 51.932796 49.104797 46.006126 44.726154 38.671898 36.424423 34.780495 33.585800 20.929722 19.593502 18.383505 16.417633 15.074667 13.806580 10.844942 9.628826 .1703E+01 HD216149 22 51 02.170 -39 09 24.79 M0III 6.886 4.633972 7.768366 7.396570 6.911816 6.104418 5.715750 5.493219 5.178350 5.042588 4.379965 4.123127 3.937343 3.802320 2.373217 2.221971 2.084892 1.862360 1.710382 1.566659 1.231064 1.093199 .1619E+01 HD217902 23 04 39.623 -53 57 53.59 K5III 6.867 6.043091 10.460057 9.900148 9.274317 7.923663 7.451108 7.168702 6.804736 6.608256 5.696443 5.370883 5.130385 4.948502 3.050964 2.851484 2.677141 2.402192 2.226292 2.054873 1.619902 1.435695 .1817E+01 HD220009 23 20 20.592 +05 22 52.60 K2III 6.284 4.813382 8.893880 8.280883 7.641560 6.487340 5.992371 5.733075 5.423833 5.266862 4.538362 4.277406 4.084091 3.942121 2.437638 2.284231 2.158134 1.960981 1.808900 1.640802 1.290035 1.145019 .1717E+01 HD220440 23 24 13.316 -51 53 28.65 M0III 7.370 6.112534 10.247568 9.756699 9.116337 8.052277 7.539326 7.245731 6.831175 6.651221 5.778456 5.438568 5.193704 5.015642 3.130662 2.931020 2.750098 2.456481 2.256316 2.066511 1.623847 1.442046 .1770E+01 HD220954 23 27 58.104 +06 22 44.24 K0.5III 5.346 5.386356 10.632524 9.852833 9.018513 7.312552 6.748816 6.446904 6.066750 5.880360 5.075012 4.743169 4.590162 4.446248 2.762855 2.586037 2.425330 2.165110 1.987900 1.819942 1.428677 1.268185 .1548E+01 HD224630 23 59 27.875 -29 29 06.71 K5III 7.234 6.605444 11.459613 10.758362 10.032406 8.574006 8.078224 7.784256 7.409858 7.201108 6.242127 5.902366 5.646367 5.448476 3.364160 3.144737 2.953580 2.650773 2.456523 2.268301 1.788403 1.585297 .1816E+01