#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = J79 #Central_Wavelength = 7.72797 #FWHM =0.564 # #Minimum_Wavelength = 5.9664 #Maximum_Wavelength = 9.9624 #Wavelength Step = 0.0120001 # #Exposure information #DIT = 0.017002 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=46217.7 #Aperture r0= 7.0 #Annulus rA1= 22.19 #Annulus rA2= 26.39 #Mean of first background file = 18922.7285156 # #encvalue wavelength transmission transmission_error 5164.0 5.9664 0.00166774 0.00145709 5174.0 5.9784 0.00202948 0.00145709 5184.0 5.9904 0.00200111 0.00145709 5194.0 6.0024 -0.00113562 0.00145709 5204.0 6.0144 0.00128789 0.00145709 5214.0 6.0264 -0.00208182 0.00145709 5224.0 6.0384 -0.00111007 0.00145709 5234.0 6.0504 0.00104556 0.00145709 5244.0 6.0624 0.0035143 0.00145709 5254.0 6.0744 0.000302147 0.00145709 5264.0 6.0864 -0.000588447 0.00145709 5274.0 6.0984 0.00366278 0.00145709 5284.0 6.1104 -0.00110228 0.00145709 5294.0 6.1224 -0.000262679 0.00145709 5304.0 6.1344 -0.000598705 0.00145709 5314.0 6.1464 -0.00104123 0.00145709 5324.0 6.1584 -3.79201e-05 0.00145709 5334.0 6.1704 0.000253715 0.00145709 5344.0 6.1824 0.00106779 0.00145709 5354.0 6.1944 0.0010253 0.00145709 5364.0 6.2064 0.000928898 0.00145709 5374.0 6.2184 0.0022229 0.00145709 5384.0 6.2304 4.59242e-05 0.00145709 5394.0 6.2424 0.00124133 0.00145709 5404.0 6.2544 -0.00243429 0.00145709 5414.0 6.2664 -0.000376816 0.00145709 5424.0 6.2784 -0.00129377 0.00145709 5434.0 6.2904 6.08812e-05 0.00145709 5444.0 6.3024 0.00221978 0.00145709 5454.0 6.3144 6.37688e-05 0.00145709 5464.0 6.3264 0.00399589 0.00145709 5474.0 6.3384 -0.000362447 0.00145709 5484.0 6.3504 0.00155292 0.00145709 5494.0 6.3624 -0.000849681 0.00145709 5504.0 6.3744 0.000557478 0.00145709 5514.0 6.3864 0.000887473 0.00145709 5524.0 6.3984 -0.000335992 0.00145709 5534.0 6.4104 -0.000983026 0.00145709 5544.0 6.4224 -0.000140352 0.00145709 5554.0 6.4344 0.000443971 0.00145709 5564.0 6.4464 -0.000105591 0.00145709 5574.0 6.4584 0.00261745 0.00145709 5584.0 6.4704 0.000797222 0.00145709 5594.0 6.4824 -0.000250108 0.00145709 5604.0 6.4944 0.000190641 0.00145709 5614.0 6.5064 -0.000232761 0.00145709 5624.0 6.5184 -0.000688317 0.00145709 5634.0 6.5304 0.00167999 0.00145709 5644.0 6.5424 0.00297021 0.00145709 5654.0 6.5544 0.00223501 0.00145709 5664.0 6.5664 0.000929711 0.00145709 5674.0 6.5784 0.00208275 0.00145709 5684.0 6.5904 0.00169234 0.00145709 5694.0 6.6024 -0.000221025 0.00145709 5704.0 6.6144 -0.000513562 0.00145709 5714.0 6.6264 0.000681735 0.00145709 5724.0 6.6384 -0.000114533 0.00145709 5734.0 6.6504 -0.00110693 0.00145709 5744.0 6.6624 -0.00210097 0.00145709 5754.0 6.6744 -0.000307947 0.00145709 5764.0 6.6864 0.00180951 0.00145709 5774.0 6.6984 2.34506e-05 0.00145709 5784.0 6.7104 0.000304689 0.00145709 5794.0 6.7224 -0.000201723 0.00145709 5804.0 6.7344 0.000882271 0.00145709 5814.0 6.7464 0.000523914 0.00145709 5824.0 6.7584 -0.00012724 0.00145709 5834.0 6.7704 0.00105541 0.00145709 5844.0 6.7824 0.00167241 0.00145709 5854.0 6.7944 0.000485074 0.00145709 5864.0 6.8064 0.00156324 0.00145709 5874.0 6.8184 0.000459339 0.00145709 5884.0 6.8304 0.000581141 0.00145709 5894.0 6.8424 0.000874324 0.00145709 5904.0 6.8544 0.00068957 0.00145709 5914.0 6.8664 0.00184004 0.00145709 5924.0 6.8784 0.0019524 0.00145709 5934.0 6.8904 0.000158049 0.00145709 5944.0 6.9024 0.00164375 0.00145709 5954.0 6.9144 0.000579778 0.00145709 5964.0 6.9264 0.00275592 0.00145709 5974.0 6.9384 0.00100668 0.00145709 5984.0 6.9504 0.00208637 0.00145709 5994.0 6.9624 -0.00114722 0.00145709 6004.0 6.9744 0.0010375 0.00145709 6014.0 6.9864 -0.00137013 0.00145709 6024.0 6.9984 0.00171159 0.00145709 6034.0 7.0104 -0.00081983 0.00145709 6044.0 7.0224 0.00134898 0.00145709 6054.0 7.0344 -0.00217444 0.00145709 6064.0 7.0464 0.00230078 0.00145709 6074.0 7.0584 0.00245797 0.00145709 6084.0 7.0704 0.00124327 0.00145709 6094.0 7.0824 0.000221262 0.00145709 6104.0 7.0944 0.000753222 0.00145709 6114.0 7.1064 0.00419683 0.00145709 6124.0 7.1184 0.00183588 0.00145709 6134.0 7.1304 -0.000653401 0.00145709 6144.0 7.1424 0.00365966 0.00145709 6154.0 7.1544 0.00196489 0.00145709 6164.0 7.1664 0.00368002 0.00145709 6174.0 7.1784 0.00365257 0.00145709 6184.0 7.1904 0.00464433 0.00145709 6194.0 7.2024 0.00539389 0.00145709 6204.0 7.2144 0.00303764 0.00145709 6214.0 7.2264 0.0100247 0.00145709 6224.0 7.2384 0.0130108 0.00145709 6234.0 7.2504 0.0169789 0.00145709 6244.0 7.2624 0.0229094 0.00145709 6254.0 7.2744 0.0267167 0.00145709 6264.0 7.2864 0.0302871 0.00145709 6274.0 7.2984 0.0374347 0.00145709 6284.0 7.3104 0.0507567 0.00145709 6294.0 7.3224 0.0666154 0.00145709 6304.0 7.3344 0.0858281 0.00145709 6314.0 7.3464 0.116237 0.00145709 6324.0 7.3584 0.147326 0.00145709 6334.0 7.3704 0.192419 0.00145709 6344.0 7.3824 0.257231 0.00145709 6354.0 7.3944 0.317303 0.00145709 6364.0 7.4064 0.389055 0.00145709 6374.0 7.4184 0.453601 0.00145709 6384.0 7.4304 0.517019 0.00145709 6394.0 7.4424 0.577728 0.00145709 6404.0 7.4544 0.650679 0.00145709 6414.0 7.4664 0.71638 0.00145709 6424.0 7.4784 0.758291 0.00145709 6434.0 7.4904 0.788663 0.00145709 6444.0 7.5024 0.819374 0.00145709 6454.0 7.5144 0.835598 0.00145709 6464.0 7.5264 0.841912 0.00145709 6474.0 7.5384 0.845415 0.00145709 6484.0 7.5504 0.850739 0.00145709 6494.0 7.5624 0.845559 0.00145709 6504.0 7.5744 0.846611 0.00145709 6514.0 7.5864 0.855092 0.00145709 6524.0 7.5984 0.854232 0.00145709 6534.0 7.6104 0.850886 0.00145709 6544.0 7.6224 0.846592 0.00145709 6554.0 7.6344 0.850897 0.00145709 6564.0 7.6464 0.848615 0.00145709 6574.0 7.6584 0.85589 0.00145709 6584.0 7.6704 0.867376 0.00145709 6594.0 7.6824 0.873084 0.00145709 6604.0 7.6944 0.890989 0.00145709 6614.0 7.7064 0.910824 0.00145709 6624.0 7.7184 0.923646 0.00145709 6634.0 7.7304 0.939546 0.00145709 6644.0 7.7424 0.962215 0.00145709 6654.0 7.7544 0.975024 0.00145709 6664.0 7.7664 0.984415 0.00145709 6674.0 7.7784 1.0 0.00145709 6684.0 7.7904 0.996499 0.00145709 6694.0 7.8024 0.991431 0.00145709 6704.0 7.8144 0.982654 0.00145709 6714.0 7.8264 0.958063 0.00145709 6724.0 7.8384 0.933958 0.00145709 6734.0 7.8504 0.910465 0.00145709 6744.0 7.8624 0.881333 0.00145709 6754.0 7.8744 0.850166 0.00145709 6764.0 7.8864 0.819685 0.00145709 6774.0 7.8984 0.785518 0.00145709 6784.0 7.9104 0.74481 0.00145709 6794.0 7.9224 0.707899 0.00145709 6804.0 7.9344 0.668912 0.00145709 6814.0 7.9464 0.623434 0.00145709 6824.0 7.9584 0.58366 0.00145709 6834.0 7.9704 0.543225 0.00145709 6844.0 7.9824 0.501472 0.00145709 6854.0 7.9944 0.458074 0.00145709 6864.0 8.0064 0.423439 0.00145709 6874.0 8.0184 0.388232 0.00145709 6884.0 8.0304 0.360487 0.00145709 6894.0 8.0424 0.336103 0.00145709 6904.0 8.0544 0.312994 0.00145709 6914.0 8.0664 0.289506 0.00145709 6924.0 8.0784 0.269949 0.00145709 6934.0 8.0904 0.246794 0.00145709 6944.0 8.1024 0.227375 0.00145709 6954.0 8.1144 0.2019 0.00145709 6964.0 8.1264 0.177504 0.00145709 6974.0 8.1384 0.15449 0.00145709 6984.0 8.1504 0.131058 0.00145709 6994.0 8.1624 0.111793 0.00145709 7004.0 8.1744 0.0922907 0.00145709 7014.0 8.1864 0.0768466 0.00145709 7024.0 8.1984 0.0615961 0.00145709 7034.0 8.2104 0.0492765 0.00145709 7044.0 8.2224 0.0423344 0.00145709 7054.0 8.2344 0.0371189 0.00145709 7064.0 8.2464 0.030437 0.00145709 7074.0 8.2584 0.0242897 0.00145709 7084.0 8.2704 0.0196908 0.00145709 7094.0 8.2824 0.0140797 0.00145709 7104.0 8.2944 0.0162253 0.00145709 7114.0 8.3064 0.0125686 0.00145709 7124.0 8.3184 0.0129254 0.00145709 7134.0 8.3304 0.0085541 0.00145709 7144.0 8.3424 0.00935289 0.00145709 7154.0 8.3544 0.00756613 0.00145709 7164.0 8.3664 0.0060115 0.00145709 7174.0 8.3784 0.00461184 0.00145709 7184.0 8.3904 0.00454107 0.00145709 7194.0 8.4024 0.0050979 0.00145709 7204.0 8.4144 0.00012546 0.00145709 7214.0 8.4264 0.00209919 0.00145709 7224.0 8.4384 0.00619134 0.00145709 7234.0 8.4504 9.802e-05 0.00145709 7244.0 8.4624 0.003117 0.00145709 7254.0 8.4744 0.000828541 0.00145709 7264.0 8.4864 0.00186547 0.00145709 7274.0 8.4984 0.00311192 0.00145709 7284.0 8.5104 4.27046e-05 0.00145709 7294.0 8.5224 0.00314955 0.00145709 7304.0 8.5344 0.000812284 0.00145709 7314.0 8.5464 0.0032845 0.00145709 7324.0 8.5584 0.0013195 0.00145709 7334.0 8.5704 0.00111983 0.00145709 7344.0 8.5824 0.00105252 0.00145709 7354.0 8.5944 0.0014085 0.00145709 7364.0 8.6064 0.00153764 0.00145709 7374.0 8.6184 -0.000600517 0.00145709 7384.0 8.6304 -5.20062e-05 0.00145709 7394.0 8.6424 0.00261844 0.00145709 7404.0 8.6544 -0.000755052 0.00145709 7414.0 8.6664 0.00142383 0.00145709 7424.0 8.6784 6.81354e-05 0.00145709 7434.0 8.6904 -7.6951e-05 0.00145709 7444.0 8.7024 0.00153139 0.00145709 7454.0 8.7144 -4.9533e-05 0.00145709 7464.0 8.7264 0.00181681 0.00145709 7474.0 8.7384 0.00162166 0.00145709 7484.0 8.7504 0.000614156 0.00145709 7494.0 8.7624 0.00432924 0.00145709 7504.0 8.7744 0.00302773 0.00145709 7514.0 8.7864 -0.000767535 0.00145709 7524.0 8.7984 0.00104643 0.00145709 7534.0 8.8104 0.000117754 0.00145709 7544.0 8.8224 0.00174684 0.00145709 7554.0 8.8344 -0.00017204 0.00145709 7564.0 8.8464 0.000768638 0.00145709 7574.0 8.8584 0.00156693 0.00145709 7584.0 8.8704 -0.00116135 0.00145709 7594.0 8.8824 -0.00120288 0.00145709 7604.0 8.8944 -0.000475018 0.00145709 7614.0 8.9064 -0.00105618 0.00145709 7624.0 8.9184 -0.00161654 0.00145709 7634.0 8.9304 0.00203679 0.00145709 7644.0 8.9424 0.000352725 0.00145709 7654.0 8.9544 -0.000700326 0.00145709 7664.0 8.9664 -0.000431067 0.00145709 7674.0 8.9784 0.00209827 0.00145709 7684.0 8.9904 -0.00166505 0.00145709 7694.0 9.0024 0.00137897 0.00145709 7704.0 9.0144 0.00251776 0.00145709 7714.0 9.0264 -0.00115936 0.00145709 7724.0 9.0384 0.00144841 0.00145709 7734.0 9.0504 5.52173e-05 0.00145709 7744.0 9.0624 0.000939378 0.00145709 7754.0 9.0744 0.000871528 0.00145709 7764.0 9.0864 0.000533734 0.00145709 7774.0 9.0984 3.71901e-05 0.00145709 7784.0 9.1104 0.00140194 0.00145709 7794.0 9.1224 0.000458755 0.00145709 7804.0 9.1344 0.00298611 0.00145709 7814.0 9.1464 0.000485228 0.00145709 7824.0 9.1584 0.000600471 0.00145709 7834.0 9.1704 0.0017304 0.00145709 7844.0 9.1824 -0.000854168 0.00145709 7854.0 9.1944 0.00163429 0.00145709 7864.0 9.2064 0.000455644 0.00145709 7874.0 9.2184 0.00154891 0.00145709 7884.0 9.2304 -6.65163e-05 0.00145709 7894.0 9.2424 -0.00108204 0.00145709 7904.0 9.2544 0.000447974 0.00145709 7914.0 9.2664 0.00149226 0.00145709 7924.0 9.2784 0.00219235 0.00145709 7934.0 9.2904 0.000935096 0.00145709 7944.0 9.3024 0.00334465 0.00145709 7954.0 9.3144 0.000207408 0.00145709 7964.0 9.3264 0.00294235 0.00145709 7974.0 9.3384 -0.000575937 0.00145709 7984.0 9.3504 -0.000402446 0.00145709 7994.0 9.3624 0.00292628 0.00145709 8004.0 9.3744 0.000410305 0.00145709 8014.0 9.3864 -0.000390608 0.00145709 8024.0 9.3984 -0.00118501 0.00145709 8034.0 9.4104 -0.00138584 0.00145709 8044.0 9.4224 0.00145962 0.00145709 8054.0 9.4344 -0.000751604 0.00145709 8064.0 9.4464 -0.000966483 0.00145709 8074.0 9.4584 9.28011e-05 0.00145709 8084.0 9.4704 0.00350021 0.00145709 8094.0 9.4824 -0.0018015 0.00145709 8104.0 9.4944 -0.000476213 0.00145709 8114.0 9.5064 -0.00277685 0.00145709 8124.0 9.5184 0.00411371 0.00145709 8134.0 9.5304 0.00109021 0.00145709 8144.0 9.5424 -3.36396e-05 0.00145709 8154.0 9.5544 0.00134261 0.00145709 8164.0 9.5664 0.000695619 0.00145709 8174.0 9.5784 0.000699857 0.00145709 8184.0 9.5904 0.000465464 0.00145709 8194.0 9.6024 -0.000433843 0.00145709 8204.0 9.6144 -0.00440056 0.00145709 8214.0 9.6264 -6.20418e-05 0.00145709 8224.0 9.6384 0.00215751 0.00145709 8234.0 9.6504 0.000909518 0.00145709 8244.0 9.6624 -0.00127959 0.00145709 8254.0 9.6744 0.00299996 0.00145709 8264.0 9.6864 -1.63723e-05 0.00145709 8274.0 9.6984 0.000414747 0.00145709 8284.0 9.7104 -0.000450399 0.00145709 8294.0 9.7224 -0.000898364 0.00145709 8304.0 9.7344 0.000978517 0.00145709 8314.0 9.7464 0.00120504 0.00145709 8324.0 9.7584 -0.000585652 0.00145709 8334.0 9.7704 -0.000472344 0.00145709 8344.0 9.7824 -0.000166694 0.00145709 8354.0 9.7944 -0.000226154 0.00145709 8364.0 9.8064 -0.0009696 0.00145709 8374.0 9.8184 8.64982e-05 0.00145709 8384.0 9.8304 0.00142989 0.00145709 8394.0 9.8424 -0.00139824 0.00145709 8404.0 9.8544 0.0014412 0.00145709 8414.0 9.8664 0.000432047 0.00145709 8424.0 9.8784 0.00184235 0.00145709 8434.0 9.8904 -0.000869991 0.00145709 8444.0 9.9024 -0.00044293 0.00145709 8454.0 9.9144 -0.00277068 0.00145709 8464.0 9.9264 -0.000912779 0.00145709 8474.0 9.9384 -0.00135776 0.00145709 8484.0 9.9504 0.000513749 0.00145709 8494.0 9.9624 0.000615199 0.00145709