#Relative Filter Curve created with the VISIR imaging detector and the VISIR calibration unit. #Author = Maximilian Haeberle Contact: max.haeberle18@gmail.com # #Filter = B87 #Central_Wavelength = 8.90563 #FWHM =0.924 # #Minimum_Wavelength = 6.966 #Maximum_Wavelength = 10.962 #Wavelength Step = 0.0119996 # #Exposure information #DIT = 0.006555 #NDIT = 50 #NABBA = 2 # #Data Analysis Information #Zeroth Order = 192 #Normalization factor=21730.0 #Aperture r0= 8.0 #Annulus rA1= 25.36 #Annulus rA2= 30.16 #Mean of first background file = 19150.3164062 # #encvalue wavelength transmission transmission_error 5997.0 6.966 -0.00516716 0.00760685 6007.0 6.978 -0.00830159 0.00760685 6017.0 6.99 -0.0073555 0.00760685 6027.0 7.002 0.0131472 0.00760685 6037.0 7.014 -0.00556807 0.00760685 6047.0 7.026 0.0134645 0.00760685 6057.0 7.038 -0.00485032 0.00760685 6067.0 7.05 0.00472065 0.00760685 6077.0 7.062 -0.00110272 0.00760685 6087.0 7.074 0.0155358 0.00760685 6097.0 7.086 -0.0190774 0.00760685 6107.0 7.098 -0.00866566 0.00760685 6117.0 7.11 -0.00792057 0.00760685 6127.0 7.122 0.00866484 0.00760685 6137.0 7.134 0.00505716 0.00760685 6147.0 7.146 -0.0095459 0.00760685 6157.0 7.158 -0.00711458 0.00760685 6167.0 7.17 -0.00928967 0.00760685 6177.0 7.182 0.00419906 0.00760685 6187.0 7.194 0.00321508 0.00760685 6197.0 7.206 0.00306205 0.00760685 6207.0 7.218 0.00691694 0.00760685 6217.0 7.23 -0.000351283 0.00760685 6227.0 7.242 0.00556142 0.00760685 6237.0 7.254 -0.0131095 0.00760685 6247.0 7.266 0.0052375 0.00760685 6257.0 7.278 -0.00735736 0.00760685 6267.0 7.29 0.00742468 0.00760685 6277.0 7.302 0.010653 0.00760685 6287.0 7.314 0.00259364 0.00760685 6297.0 7.326 0.0129364 0.00760685 6307.0 7.338 -0.000584783 0.00760685 6317.0 7.35 -0.00629892 0.00760685 6327.0 7.362 0.0053129 0.00760685 6337.0 7.374 0.0151356 0.00760685 6347.0 7.386 -0.01188 0.00760685 6357.0 7.398 -0.000976187 0.00760685 6367.0 7.41 -0.00504915 0.00760685 6377.0 7.422 -0.005823 0.00760685 6387.0 7.434 0.00761959 0.00760685 6397.0 7.446 -0.00245939 0.00760685 6407.0 7.458 0.00429942 0.00760685 6417.0 7.47 -0.000976889 0.00760685 6427.0 7.482 0.00409732 0.00760685 6437.0 7.494 0.00823455 0.00760685 6447.0 7.506 0.000469524 0.00760685 6457.0 7.518 0.0050069 0.00760685 6467.0 7.53 0.00251106 0.00760685 6477.0 7.542 0.00289504 0.00760685 6487.0 7.554 0.00699797 0.00760685 6497.0 7.566 -0.0107779 0.00760685 6507.0 7.578 0.00057357 0.00760685 6517.0 7.59 -2.51233e-05 0.00760685 6527.0 7.602 0.00502462 0.00760685 6537.0 7.614 0.0166861 0.00760685 6547.0 7.626 -0.00190695 0.00760685 6557.0 7.638 -0.000579786 0.00760685 6567.0 7.65 -0.00214115 0.00760685 6577.0 7.662 -0.0121488 0.00760685 6587.0 7.674 0.00427898 0.00760685 6597.0 7.686 0.00709051 0.00760685 6607.0 7.698 -0.00168481 0.00760685 6617.0 7.71 0.00666481 0.00760685 6627.0 7.722 0.0109028 0.00760685 6637.0 7.734 0.00342975 0.00760685 6647.0 7.746 0.0155671 0.00760685 6657.0 7.758 -0.00288233 0.00760685 6667.0 7.77 0.0153337 0.00760685 6677.0 7.782 0.00333374 0.00760685 6687.0 7.794 0.00770992 0.00760685 6697.0 7.806 0.0284264 0.00760685 6707.0 7.818 0.0098367 0.00760685 6717.0 7.83 0.0126795 0.00760685 6727.0 7.842 0.0165756 0.00760685 6737.0 7.854 0.0268585 0.00760685 6747.0 7.866 0.0207319 0.00760685 6757.0 7.878 0.0174762 0.00760685 6767.0 7.89 0.0228896 0.00760685 6777.0 7.902 0.0180627 0.00760685 6787.0 7.914 0.0248234 0.00760685 6797.0 7.926 0.0336838 0.00760685 6807.0 7.938 0.0166517 0.00760685 6817.0 7.95 0.0293826 0.00760685 6827.0 7.962 0.0293222 0.00760685 6837.0 7.974 0.0285753 0.00760685 6847.0 7.986 0.0299359 0.00760685 6857.0 7.998 0.0251383 0.00760685 6867.0 8.01 0.0389627 0.00760685 6877.0 8.022 0.0342564 0.00760685 6887.0 8.034 0.0424526 0.00760685 6897.0 8.046 0.0604464 0.00760685 6907.0 8.058 0.0452237 0.00760685 6917.0 8.07 0.0606368 0.00760685 6927.0 8.082 0.066349 0.00760685 6937.0 8.094 0.0721964 0.00760685 6947.0 8.106 0.0803427 0.00760685 6957.0 8.118 0.09544 0.00760685 6967.0 8.13 0.1074 0.00760685 6977.0 8.142 0.114378 0.00760685 6987.0 8.154 0.140737 0.00760685 6997.0 8.166 0.153319 0.00760685 7007.0 8.178 0.173873 0.00760685 7017.0 8.19 0.172672 0.00760685 7027.0 8.202 0.184798 0.00760685 7037.0 8.214 0.195741 0.00760685 7047.0 8.226 0.219471 0.00760685 7057.0 8.238 0.234125 0.00760685 7067.0 8.25 0.24685 0.00760685 7077.0 8.262 0.257699 0.00760685 7087.0 8.274 0.268689 0.00760685 7097.0 8.286 0.299808 0.00760685 7107.0 8.298 0.309608 0.00760685 7117.0 8.31 0.326714 0.00760685 7127.0 8.322 0.356343 0.00760685 7137.0 8.334 0.374431 0.00760685 7147.0 8.346 0.387077 0.00760685 7157.0 8.358 0.388134 0.00760685 7167.0 8.37 0.42194 0.00760685 7177.0 8.382 0.427386 0.00760685 7187.0 8.394 0.432511 0.00760685 7197.0 8.406 0.442777 0.00760685 7207.0 8.418 0.449391 0.00760685 7217.0 8.43 0.468322 0.00760685 7227.0 8.442 0.474543 0.00760685 7237.0 8.454 0.479563 0.00760685 7247.0 8.466 0.489384 0.00760685 7257.0 8.478 0.495698 0.00760685 7267.0 8.49 0.505606 0.00760685 7277.0 8.502 0.505891 0.00760685 7287.0 8.514 0.531334 0.00760685 7297.0 8.526 0.528137 0.00760685 7307.0 8.538 0.551968 0.00760685 7317.0 8.55 0.552179 0.00760685 7327.0 8.562 0.583387 0.00760685 7337.0 8.574 0.609598 0.00760685 7347.0 8.586 0.621745 0.00760685 7357.0 8.598 0.62815 0.00760685 7367.0 8.61 0.662077 0.00760685 7377.0 8.622 0.687988 0.00760685 7387.0 8.634 0.690055 0.00760685 7397.0 8.646 0.705156 0.00760685 7407.0 8.658 0.722435 0.00760685 7417.0 8.67 0.736864 0.00760685 7427.0 8.682 0.749912 0.00760685 7437.0 8.694 0.781938 0.00760685 7447.0 8.706 0.76893 0.00760685 7457.0 8.718 0.791418 0.00760685 7467.0 8.73 0.795858 0.00760685 7477.0 8.742 0.816432 0.00760685 7487.0 8.754 0.807166 0.00760685 7497.0 8.766 0.834565 0.00760685 7507.0 8.778 0.839471 0.00760685 7517.0 8.79 0.838548 0.00760685 7527.0 8.802 0.853771 0.00760685 7537.0 8.814 0.868239 0.00760685 7547.0 8.826 0.875272 0.00760685 7557.0 8.838 0.875898 0.00760685 7567.0 8.85 0.907936 0.00760685 7577.0 8.862 0.903338 0.00760685 7587.0 8.874 0.918154 0.00760685 7597.0 8.886 0.889275 0.00760685 7607.0 8.898 0.934831 0.00760685 7617.0 8.91 0.93364 0.00760685 7627.0 8.922 0.942893 0.00760685 7637.0 8.934 0.966713 0.00760685 7647.0 8.946 0.963881 0.00760685 7657.0 8.958 0.969599 0.00760685 7667.0 8.97 0.985015 0.00760685 7677.0 8.982 0.990384 0.00760685 7687.0 8.994 1.0 0.00760685 7697.0 9.006 0.982217 0.00760685 7707.0 9.018 0.994726 0.00760685 7717.0 9.03 0.983721 0.00760685 7727.0 9.042 0.98131 0.00760685 7737.0 9.054 0.974626 0.00760685 7747.0 9.066 0.963931 0.00760685 7757.0 9.078 0.943285 0.00760685 7767.0 9.09 0.946757 0.00760685 7777.0 9.102 0.925385 0.00760685 7787.0 9.114 0.90765 0.00760685 7797.0 9.126 0.901049 0.00760685 7807.0 9.138 0.894013 0.00760685 7817.0 9.15 0.882239 0.00760685 7827.0 9.162 0.884532 0.00760685 7837.0 9.174 0.875758 0.00760685 7847.0 9.186 0.846306 0.00760685 7857.0 9.198 0.8848 0.00760685 7867.0 9.21 0.860536 0.00760685 7877.0 9.222 0.867063 0.00760685 7887.0 9.234 0.871085 0.00760685 7897.0 9.246 0.88264 0.00760685 7907.0 9.258 0.870022 0.00760685 7917.0 9.27 0.896371 0.00760685 7927.0 9.282 0.879927 0.00760685 7937.0 9.294 0.898489 0.00760685 7947.0 9.306 0.881193 0.00760685 7957.0 9.318 0.884932 0.00760685 7967.0 9.33 0.840544 0.00760685 7977.0 9.342 0.82142 0.00760685 7987.0 9.354 0.766727 0.00760685 7997.0 9.366 0.714036 0.00760685 8007.0 9.378 0.650592 0.00760685 8017.0 9.39 0.584262 0.00760685 8027.0 9.402 0.521769 0.00760685 8037.0 9.414 0.465524 0.00760685 8047.0 9.426 0.392741 0.00760685 8057.0 9.438 0.351237 0.00760685 8067.0 9.45 0.300275 0.00760685 8077.0 9.462 0.246435 0.00760685 8087.0 9.474 0.2183 0.00760685 8097.0 9.486 0.182892 0.00760685 8107.0 9.498 0.15341 0.00760685 8117.0 9.51 0.140658 0.00760685 8127.0 9.522 0.107936 0.00760685 8137.0 9.534 0.105409 0.00760685 8147.0 9.546 0.0881688 0.00760685 8157.0 9.558 0.0787392 0.00760685 8167.0 9.57 0.0609374 0.00760685 8177.0 9.582 0.0750159 0.00760685 8187.0 9.594 0.0593834 0.00760685 8197.0 9.606 0.0652429 0.00760685 8207.0 9.618 0.0467938 0.00760685 8217.0 9.63 0.041828 0.00760685 8227.0 9.642 0.0484404 0.00760685 8237.0 9.654 0.0431653 0.00760685 8247.0 9.666 0.0410373 0.00760685 8257.0 9.678 0.028704 0.00760685 8267.0 9.69 0.0411978 0.00760685 8277.0 9.702 0.0260797 0.00760685 8287.0 9.714 0.0393953 0.00760685 8297.0 9.726 0.0284229 0.00760685 8307.0 9.738 0.0328483 0.00760685 8317.0 9.75 0.0122014 0.00760685 8327.0 9.762 0.0326969 0.00760685 8337.0 9.774 0.0191996 0.00760685 8347.0 9.786 0.0252603 0.00760685 8357.0 9.798 0.0234846 0.00760685 8367.0 9.81 0.0132709 0.00760685 8377.0 9.822 0.00956955 0.00760685 8387.0 9.834 -0.00689434 0.00760685 8397.0 9.846 0.0114818 0.00760685 8407.0 9.858 0.00782857 0.00760685 8417.0 9.87 0.00633959 0.00760685 8427.0 9.882 0.0133013 0.00760685 8437.0 9.894 0.015602 0.00760685 8447.0 9.906 0.00169918 0.00760685 8457.0 9.918 0.0176083 0.00760685 8467.0 9.93 0.00572688 0.00760685 8477.0 9.942 0.0151007 0.00760685 8487.0 9.954 -0.0111366 0.00760685 8497.0 9.966 0.0105332 0.00760685 8507.0 9.978 -0.00412315 0.00760685 8517.0 9.99 0.00148855 0.00760685 8527.0 10.002 0.00273906 0.00760685 8537.0 10.014 0.00702714 0.00760685 8547.0 10.026 0.00304399 0.00760685 8557.0 10.038 -0.00903631 0.00760685 8567.0 10.05 0.0122871 0.00760685 8577.0 10.062 0.00201668 0.00760685 8587.0 10.074 0.00305843 0.00760685 8597.0 10.086 -0.00285513 0.00760685 8607.0 10.098 -0.00270816 0.00760685 8617.0 10.11 -0.00423379 0.00760685 8627.0 10.122 -0.000797284 0.00760685 8637.0 10.134 -0.00463032 0.00760685 8647.0 10.146 0.00939629 0.00760685 8657.0 10.158 0.0148368 0.00760685 8667.0 10.17 0.00395905 0.00760685 8677.0 10.182 -0.00452515 0.00760685 8687.0 10.194 0.0136238 0.00760685 8697.0 10.206 0.018507 0.00760685 8707.0 10.218 0.0175072 0.00760685 8717.0 10.23 -0.011946 0.00760685 8727.0 10.242 0.00869697 0.00760685 8737.0 10.254 0.00514265 0.00760685 8747.0 10.266 -0.00108757 0.00760685 8757.0 10.278 0.00663628 0.00760685 8767.0 10.29 0.000274114 0.00760685 8777.0 10.302 0.00608197 0.00760685 8787.0 10.314 0.00642351 0.00760685 8797.0 10.326 0.0149563 0.00760685 8807.0 10.338 -0.00101966 0.00760685 8817.0 10.35 -0.00243725 0.00760685 8827.0 10.362 -0.00366036 0.00760685 8837.0 10.374 0.00492649 0.00760685 8847.0 10.386 -0.00531689 0.00760685 8857.0 10.398 0.00344088 0.00760685 8867.0 10.41 0.00675728 0.00760685 8877.0 10.422 -0.00657183 0.00760685 8887.0 10.434 -0.00343772 0.00760685 8897.0 10.446 -0.00340938 0.00760685 8907.0 10.458 -0.0122786 0.00760685 8917.0 10.47 0.00804536 0.00760685 8927.0 10.482 0.00978494 0.00760685 8937.0 10.494 0.0125069 0.00760685 8947.0 10.506 0.00544705 0.00760685 8957.0 10.518 -0.0040329 0.00760685 8967.0 10.53 0.00738546 0.00760685 8977.0 10.542 0.00796015 0.00760685 8987.0 10.554 -0.00263043 0.00760685 8997.0 10.566 0.003005 0.00760685 9007.0 10.578 0.00143853 0.00760685 9017.0 10.59 -0.00626657 0.00760685 9027.0 10.602 0.00236417 0.00760685 9037.0 10.614 -0.0102994 0.00760685 9047.0 10.626 -0.0142578 0.00760685 9057.0 10.638 0.00141389 0.00760685 9067.0 10.65 0.00444928 0.00760685 9077.0 10.662 0.00306673 0.00760685 9087.0 10.674 0.00898619 0.00760685 9097.0 10.686 0.00554501 0.00760685 9107.0 10.698 -0.00243781 0.00760685 9117.0 10.71 -0.000733928 0.00760685 9127.0 10.722 0.00685674 0.00760685 9137.0 10.734 -0.00607371 0.00760685 9147.0 10.746 0.00262429 0.00760685 9157.0 10.758 0.0104313 0.00760685 9167.0 10.77 -0.00474399 0.00760685 9177.0 10.782 -0.00558495 0.00760685 9187.0 10.794 -0.0113561 0.00760685 9197.0 10.806 -0.00906242 0.00760685 9207.0 10.818 0.00115624 0.00760685 9217.0 10.83 -0.00399991 0.00760685 9227.0 10.842 0.0144234 0.00760685 9237.0 10.854 0.00319342 0.00760685 9247.0 10.866 0.00226123 0.00760685 9257.0 10.878 0.0014004 0.00760685 9267.0 10.89 0.0100395 0.00760685 9277.0 10.902 0.0180917 0.00760685 9287.0 10.914 -0.000991367 0.00760685 9297.0 10.926 -0.0103681 0.00760685 9307.0 10.938 -0.00815716 0.00760685 9317.0 10.95 -0.00222298 0.00760685 9327.0 10.962 -0.0120899 0.00760685