# number of points on sci filter + aux + bad z = 0
# number of points on sci filter               = 2
# number of positions in lambda                = 301
# noof scans  1            1          
# x_pos     162.640000  -162.640000 
# y_pos       0.000000     0.000000 
# angle       2.960000     2.960000 
# z_pos      10.000000    10.000000 
# r_pos     162.640000   162.640000 
# phi         0.000000     3.141593 
# gnupl col      2            3      
# pos_id        49           50      
#
# lambda for peak transmission
#          482.9050000  482.9050000 
# peak transmission
#            0.7735743    0.7603654 
# lambda blue with 1/2 of peak transmission
#          389.5062244  392.8238527 
# lambda red  with 1/2 of peak transmission
#          528.3415212  528.4381120 
# half width                              
#          138.8352968  135.6142593 
# central wavelength                      
#          458.9238728  460.6309823 
# central wavelength calculated as SAGEM (mean frequency)
#          448.4236348  450.6494418 
# lambda blue with 80% of peak transmission
#          398.4668177  402.3273193 
# lambda red  with 80% of peak transmission
#          523.7706449  518.2011669 
# lambda blue with 0.0001 of peak transmission
#          375.8395039  376.0698930 
# lambda red  with 0.0001 of peak transmission
#          565.2327230  564.5335554 
# ATB calculated from points above 80%
#            0.7303996    0.7264485 
# ATB calculated from points above 50%
#            0.7030254    0.6995865 
# ABR calculated from points below and above 0.0001
#            0.0005606    0.0005197 
# minCWL      = 458.923873 at column =  2, at id = 49 
# maxCWL      = 460.630982 at column =  3, at id = 50 
# difference =    1.7071095 
# minBW       = 135.614259 at column =  3, at id = 50 
# maxBW       = 138.835297 at column =  2, at id = 49 
# difference =    3.2210376 
# minBlueEdge = 389.506224 at column =  2, at id = 49 
# maxBlueEdge = 392.823853 at column =  3, at id = 50 
# difference =    3.3176283 
# minRedEdge  = 528.341521 at column =  2, at id = 49 
# maxRedEdge  = 528.438112 at column =  3, at id = 50 
# difference =    0.0965907 
# minABR      = 0.000520 at column =  3, at id = 50 
# maxABR      = 0.000561 at column =  2, at id = 49 
# difference =    0.0000409 
  299.645     0.000096     0.000162 
  302.654     0.000073     0.000021 
  305.662     0.000062    -0.000001 
  308.671     0.000019    -0.000013 
  311.679     0.000015    -0.000010 
  314.687     0.000015    -0.000001 
  317.694     0.000030    -0.000001 
  320.702     0.000012    -0.000006 
  323.709     0.000010     0.000003 
  326.716     0.000003     0.000004 
  329.665     0.000005    -0.000000 
  332.672     0.000001    -0.000000 
  335.678    -0.000002     0.000004 
  338.683    -0.000001     0.000001 
  341.689     0.000006     0.000001 
  344.694     0.000009     0.000006 
  347.699     0.000006    -0.000002 
  350.703     0.000005     0.000001 
  353.707     0.000004    -0.000001 
  356.711     0.000002     0.000002 
  359.715     0.000002     0.000001 
  362.718     0.000004    -0.000000 
  365.721     0.000006     0.000002 
  368.724     0.000006     0.000001 
  371.726     0.000004     0.000001 
  374.728     0.000006     0.000001 
  377.730     0.000198     0.000169 
  380.788     0.003128     0.001779 
  383.789     0.012222     0.006697 
  386.789     0.083627     0.061262 
  389.790     0.418448     0.307465 
  392.790     0.459054     0.379190 
  395.790     0.463113     0.467190 
  398.789     0.637605     0.626621 
  401.788     0.638874     0.603615 
  404.787     0.639607     0.629625 
  407.785     0.691903     0.684062 
  410.783     0.698251     0.680802 
  413.781     0.711107     0.703564 
  416.834     0.730253     0.721559 
  419.831     0.751211     0.739335 
  422.828     0.735789     0.724469 
  425.824     0.743071     0.729459 
  428.820     0.753470     0.745704 
  431.815     0.766859     0.758415 
  434.810     0.763641     0.751372 
  437.862     0.734621     0.714663 
  440.856     0.736911     0.726025 
  443.850     0.762219     0.755280 
  446.844     0.750062     0.730246 
  449.837     0.740156     0.719446 
  452.830     0.748579     0.735068 
  455.878     0.762329     0.753407 
  458.870     0.762136     0.749634 
  461.862     0.748819     0.735255 
  464.853     0.752709     0.744268 
  467.901     0.768177     0.760249 
  470.891     0.764139     0.750753 
  473.881     0.744785     0.731248 
  476.871     0.744904     0.735719 
  479.916     0.765358     0.758315 
  482.905     0.773574     0.760365 
  485.894     0.753186     0.732515 
  488.882     0.730527     0.712853 
  491.925     0.741514     0.734230 
  494.913     0.763406     0.754635 
  497.899     0.755822     0.734208 
  500.942     0.737244     0.710735 
  503.928     0.729510     0.706223 
  506.913     0.729076     0.711561 
  509.954     0.737882     0.724455 
  512.939     0.729457     0.708389 
  515.923     0.678930     0.645831 
  518.963     0.634110     0.595739 
  521.946     0.634501     0.592920 
  524.929     0.608930     0.575748 
  527.967     0.417618     0.416912 
  530.949     0.172135     0.184425 
  533.987     0.055066     0.060607 
  536.968     0.018543     0.020194 
  539.948     0.007221     0.007661 
  542.984     0.003176     0.003293 
  545.964     0.001567     0.001601 
  548.999     0.000820     0.000823 
  551.977     0.000467     0.000460 
  555.012     0.000280     0.000273 
  557.989     0.000180     0.000172 
  561.023     0.000123     0.000117 
  563.999     0.000087     0.000080 
  567.032     0.000063     0.000058 
  570.007     0.000049     0.000045 
  573.038     0.000039     0.000032 
  576.013     0.000033     0.000029 
  579.043     0.000028     0.000024 
  582.017     0.000025     0.000019 
  585.046     0.000021     0.000018 
  588.019     0.000022     0.000012 
  591.047     0.000020     0.000014 
  594.019     0.000019     0.000013 
  597.046     0.000019     0.000012 
  600.073     0.000019     0.000013 
  603.043     0.000021     0.000012 
  606.068     0.000022     0.000011 
  609.038     0.000027     0.000014 
  612.062     0.000027     0.000013 
  615.086     0.000027     0.000016 
  618.053     0.000029     0.000016 
  621.076     0.000032     0.000014 
  624.099     0.000036     0.000017 
  627.064     0.000040     0.000021 
  630.086     0.000045     0.000025 
  633.106     0.000058     0.000029 
  636.071     0.000060     0.000026 
  639.090     0.000046     0.000019 
  642.109     0.000032     0.000011 
  645.128     0.000025     0.000012 
  648.090     0.000021     0.000008 
  651.107     0.000015     0.000004 
  654.123     0.000010    -0.000001 
  657.139     0.000007     0.000001 
  660.099     0.000008     0.000001 
  663.114     0.000004     0.000001 
  666.129     0.000008     0.000001 
  669.142     0.000011     0.000004 
  672.155     0.000019     0.000011 
  675.168     0.000043     0.000027 
  678.124     0.000086     0.000053 
  681.136     0.000089     0.000064 
  684.146     0.000054     0.000045 
  687.157     0.000032     0.000028 
  690.166     0.000022     0.000017 
  693.175     0.000015     0.000013 
  696.183     0.000012     0.000012 
  699.191     0.000016     0.000012 
  702.198     0.000019     0.000013 
  705.205     0.000023     0.000021 
  708.211     0.000030     0.000025 
  711.216     0.000034     0.000028 
  714.220     0.000031     0.000025 
  717.224     0.000026     0.000021 
  720.228     0.000018     0.000016 
  723.230     0.000018     0.000012 
  726.232     0.000012     0.000013 
  729.234     0.000013     0.000013 
  732.234     0.000015     0.000013 
  735.235     0.000016     0.000016 
  738.234     0.000019     0.000019 
  741.233     0.000026     0.000026 
  744.231     0.000032     0.000034 
  747.228     0.000046     0.000037 
  750.225     0.000051     0.000042 
  753.221     0.000051     0.000045 
  756.272     0.000049     0.000045 
  759.267     0.000051     0.000041 
  762.261     0.000053     0.000051 
  765.254     0.000058     0.000058 
  768.247     0.000072     0.000073 
  771.294     0.000093     0.000100 
  774.286     0.000136     0.000142 
  777.277     0.000207     0.000226 
  780.266     0.000330     0.000358 
  783.311     0.000518     0.000533 
  786.300     0.000758     0.000731 
  789.288     0.001004     0.000922 
  792.275     0.001174     0.001170 
  795.316     0.001412     0.001446 
  798.302     0.001688     0.001704 
  801.287     0.001936     0.001889 
  804.327     0.001962     0.001789 
  807.310     0.001593     0.001353 
  810.348     0.001062     0.000874 
  813.331     0.000640     0.000533 
  816.312     0.000377     0.000324 
  819.348     0.000222     0.000200 
  822.328     0.000141     0.000125 
  825.362     0.000089     0.000081 
  828.341     0.000060     0.000051 
  831.374     0.000040     0.000034 
  834.351     0.000027     0.000023 
  837.382     0.000019     0.000016 
  840.357     0.000012     0.000015 
  843.387     0.000012     0.000011 
  846.361     0.000009     0.000009 
  849.389     0.000001     0.000003 
  852.362     0.000005     0.000005 
  855.389     0.000004     0.000000 
  858.359     0.000004     0.000001 
  861.385     0.000001     0.000000 
  864.409     0.000001     0.000001 
  867.378     0.000001     0.000001 
  870.400     0.000001     0.000001 
  873.422     0.000001     0.000001 
  876.389     0.000001     0.000001 
  879.409     0.000001     0.000001 
  882.428     0.000001     0.000001 
  885.447     0.000001     0.000001 
  888.410     0.000003     0.000001 
  891.427     0.000007     0.000001 
  894.444     0.000006     0.000001 
  897.459     0.000007     0.000001 
  900.419     0.000007     0.000003 
  903.433     0.000007     0.000006 
  906.446     0.000011     0.000007 
  909.458     0.000012     0.000008 
  912.469     0.000014     0.000010 
  915.480     0.000014     0.000011 
  918.489     0.000015     0.000012 
  921.443     0.000016     0.000012 
  924.451     0.000016     0.000013 
  927.458     0.000015     0.000012 
  930.465     0.000013     0.000011 
  933.470     0.000011     0.000008 
  936.475     0.000010     0.000007 
  939.478     0.000009     0.000007 
  942.481     0.000008     0.000006 
  945.483     0.000008     0.000005 
  948.484     0.000007     0.000005 
  951.484     0.000006     0.000005 
  954.538     0.000008     0.000006 
  957.537     0.000009     0.000007 
  960.534     0.000010     0.000008 
  963.531     0.000011     0.000009 
  966.526     0.000012     0.000009 
  969.521     0.000013     0.000009 
  972.515     0.000012     0.000008 
  975.563     0.000011     0.000008 
  978.555     0.000010     0.000008 
  981.546     0.000010     0.000008 
  984.537     0.000010     0.000008 
  987.580     0.000010     0.000008 
  990.569     0.000011     0.000009 
  993.556     0.000012     0.000010 
  996.543     0.000012     0.000010 
  999.583     0.000012     0.000010 
 1002.568     0.000012     0.000010 
 1005.552     0.000012     0.000010 
 1008.589     0.000012     0.000010 
 1011.571     0.000012     0.000010 
 1014.606     0.000012     0.000010 
 1017.587     0.000013     0.000011 
 1020.620     0.000014     0.000012 
 1023.598     0.000015     0.000013 
 1026.629     0.000016     0.000015 
 1029.606     0.000018     0.000015 
 1032.635     0.000018     0.000015 
 1035.610     0.000016     0.000014 
 1038.637     0.000013     0.000010 
 1041.610     0.000010     0.000008 
 1044.635     0.000008     0.000007 
 1047.660     0.000007     0.000005 
 1050.629     0.000005     0.000004 
 1053.652     0.000005     0.000004 
 1056.620     0.000004     0.000003 
 1059.640     0.000003     0.000003 
 1062.660     0.000003     0.000002 
 1065.678     0.000003     0.000002 
 1068.642     0.000003     0.000002 
 1071.658     0.000003     0.000002 
 1074.674     0.000003     0.000002 
 1077.688     0.000003     0.000002 
 1080.702     0.000003     0.000002 
 1083.660     0.000003     0.000002 
 1086.672     0.000003     0.000002 
 1089.682     0.000003     0.000003 
 1092.691     0.000003     0.000003 
 1095.699     0.000003     0.000003 
 1098.707     0.000003     0.000003 
 1101.713     0.000003     0.000003 
 1104.718     0.000002     0.000002 
 1107.722     0.000001     0.000001 
 1110.725     0.000000     0.000000 
 1113.727     0.000000     0.000000 
 1116.728     0.000000     0.000000 
 1119.728     0.000000     0.000000 
 1122.726     0.000000     0.000000 
 1125.724     0.000000     0.000000 
 1128.720     0.000000     0.000000 
 1131.770     0.000000     0.000000 
 1134.764     0.000000     0.000000 
 1137.757     0.000000     0.000000 
 1140.749     0.000000     0.000000 
 1143.741     0.000000     0.000000 
 1146.784     0.000000     0.000000 
 1149.773     0.000000     0.000000 
 1152.761     0.000000     0.000000 
 1155.801     0.000000     0.000000 
 1158.786     0.000000     0.000000 
 1161.771     0.000000     0.000000 
 1164.807     0.000000     0.000000 
 1167.790     0.000000     0.000000 
 1170.771     0.000000     0.000000 
 1173.804     0.000000     0.000000 
 1176.783     0.000000     0.000000 
 1179.814     0.000000     0.000000 
 1182.790     0.000000     0.000000 
 1185.819     0.000000     0.000000 
 1188.793     0.000000     0.000000 
 1191.820     0.000000     0.000000 
 1194.845     0.000000     0.000000 
 1197.815     0.000000     0.000000 
 1200.838     0.000000     0.000000 