# number of points on sci filter + aux + bad z = 49
# number of points on sci filter               = 47
# number of positions in lambda                = 301
# noof scans  2            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000     2.000000    -2.000000     4.000000    -4.000000     6.000000    -6.000000    28.750000    20.330000     0.000000   -20.330000   -28.750000   -20.330000     0.000000    20.330000    57.500000    40.660000     0.000000   -40.660000   -57.510000   -40.660000     0.000000    40.660000    86.250000    60.990000     0.000000   -60.990000   -86.260000   -60.990000     0.000000    60.990000   115.000000    81.320000     0.000000   -81.320000  -115.010000   -81.320000     0.000000    81.320000   101.650000  -101.650000  -101.650000   101.650000   121.980000  -121.980000  -121.980000   121.980000   162.640000  -162.640000 
# y_pos       0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    20.330000    28.750000    20.330000     0.000000   -20.330000   -28.760000   -20.330000     0.000000    40.660000    57.500000    40.660000     0.000000   -40.660000   -57.510000   -40.660000     0.000000    60.990000    86.250000    60.990000     0.000000   -60.990000   -86.260000   -60.990000     0.000000    81.320000   115.000000    81.320000     0.000000   -81.320000  -115.010000   -81.320000   101.650000   101.650000  -101.650000  -101.650000   121.980000   121.980000  -121.980000  -121.980000     0.000000     0.000000 
# angle       0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.520000     0.520000     0.520000     0.520000     0.520000     0.520000     0.520000     0.520000     1.050000     1.050000     1.050000     1.050000     1.050000     1.050000     1.050000     1.050000     1.570000     1.570000     1.570000     1.570000     1.570000     1.570000     1.570000     1.570000     2.100000     2.100000     2.100000     2.100000     2.100000     2.100000     2.100000     2.100000     2.620000     2.620000     2.620000     2.620000     3.140000     3.140000     3.140000     3.140000     2.960000     2.960000 
# z_pos       0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     1.000000     1.000000     1.000000     1.000000     1.000000     1.000000     1.000000     1.000000     2.000000     2.000000     2.000000     2.000000     2.000000     2.000000     2.000000     2.000000     3.000000     3.000000     3.000000     3.000000     3.000000     3.000000     3.000000     3.000000     4.000000     4.000000     4.000000     4.000000     4.000000     4.000000     4.000000     4.000000     5.000000     5.000000     5.000000     5.000000     6.000000     6.000000     6.000000     6.000000    10.000000    10.000000 
# r_pos       0.000000     2.000000     2.000000     4.000000     4.000000     6.000000     6.000000    28.750962    28.750962    28.750962    28.750962    28.750962    28.750962    28.750962    28.750962    57.501923    57.501923    57.501923    57.501923    57.501923    57.501923    57.501923    57.501923    86.250000    86.250000    86.250000    86.250000    86.250000    86.250000    86.250000    86.250000   115.000000   115.000000   115.000000   115.000000   115.000000   115.000000   115.000000   115.000000   143.754809   143.754809   143.754809   143.754809   172.505770   172.505770   172.505770   172.505770   162.640000   162.640000 
# phi         0.000000     0.000000     3.141593     0.000000     3.141593     0.000000     3.141593     0.000000     0.785398     1.570796     2.356194     3.141593     3.926806     4.712204     5.497602     0.000000     0.785398     1.570796     2.356194     3.141593     3.926806     4.712204     5.497602     0.000000     0.785398     1.570796     2.356194     3.141593     3.926806     4.712204     5.497602     0.000000     0.785398     1.570796     2.356194     3.141593     3.926806     4.712204     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.000000     3.141593 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14           15           16           17           18           19           20           21           22           23           24           25           26           27           28           29           30           31           32           33           34           35           36           37           38           39           40           41           42           43           44           45           46           47           48           49           50      
# pos_id         2            3            4            5            6            7            8            9           10           11           12           13           14           15           16           17           18           19           20           21           22           23           24           25           26           27           28           29           30           31           32           33           34           35           36           37           38           39           40           41           42           43           44           45           46           47           48           49           50      
#
# modified transmissions for science filter (columns 1 until 47) with lambda < 360.000000 (replaced original with mean values calculated from all measurements for science filter) 
# lambda for peak transmission
#          497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  497.8990000  494.9130000  497.8990000  488.8820000  488.8820000  494.9130000  494.9130000  500.9420000  473.8810000 
# peak transmission
#            0.9099720    0.9080150    0.9097980    0.9097030    0.9111020    0.9110020    0.9112410    0.9072830    0.9077130    0.9076800    0.9064380    0.9057660    0.9069000    0.9075050    0.9084960    0.9018170    0.9032430    0.9022310    0.9024570    0.9016520    0.9025520    0.9031060    0.9029530    0.8968110    0.8964050    0.8975390    0.8944120    0.8943480    0.8965640    0.8961220    0.8961980    0.8943510    0.8927580    0.8920680    0.8909520    0.8950420    0.8901410    0.8915160    0.8925920    0.8881060    0.8840540    0.8824840    0.8872530    0.8786910    0.8734300    0.8788190    0.8845380    0.9300940    0.9253000 
# lambda blue with 1/2 of peak transmission
#          405.8513131  405.8330178  405.8500941  405.8171896  405.8246169  405.7695496  405.8239885  404.6094384  405.0788639  405.1910972  404.9272342  404.5637491  404.3615795  404.2922248  404.1250438  404.5734444  404.5401805  404.8561377  404.8773741  404.7687117  404.7578522  404.4821622  404.4761300  405.8982409  406.0453655  406.1471718  406.2113142  406.2061193  406.2792619  405.8568460  405.7744572  407.5620475  407.6194745  407.9840974  408.1292297  408.1988078  408.0144452  407.7322290  407.4769689  409.1648901  409.9705356  409.6546837  409.2186182  410.8847227  411.6944082  411.6379022  410.7792158  424.0516270  425.1041160 
# lambda red  with 1/2 of peak transmission
#          539.1054687  539.1013191  539.1223129  539.0558999  539.1155430  539.0032180  539.0833276  537.4362755  538.0226028  538.1722154  537.8589994  537.3892990  537.1648010  537.0586035  536.9202701  537.2429243  537.2957376  537.5704432  537.5899692  537.4827331  537.4973378  537.1370840  537.1518897  538.6551896  538.9396919  538.9896176  539.0749468  538.9830763  539.0827705  538.6170532  538.5571934  540.6133661  540.7594956  541.1046693  541.1513577  541.0527495  540.8990493  540.7184349  540.5070145  543.1119024  543.6461242  543.1347405  542.9572028  547.0203011  546.6575663  546.4412119  546.2378968  543.4303003  544.1545559 
# half width                              
#          133.2541556  133.2683013  133.2722188  133.2387103  133.2909261  133.2336685  133.2593391  132.8268371  132.9437389  132.9811182  132.9317652  132.8255499  132.8032215  132.7663787  132.7952263  132.6694799  132.7555571  132.7143055  132.7125951  132.7140214  132.7394856  132.6549218  132.6757597  132.7569486  132.8943264  132.8424458  132.8636326  132.7769570  132.8035086  132.7602072  132.7827362  133.0513185  133.1400211  133.1205718  133.0221279  132.8539417  132.8846042  132.9862059  133.0300456  133.9470123  133.6755886  133.4800568  133.7385846  136.1355784  134.9631582  134.8033097  135.4586809  119.3786733  119.0504400 
# central wavelength                      
#          472.4783909  472.4671685  472.4862035  472.4365447  472.4700799  472.3863838  472.4536581  471.0228570  471.5507334  471.6816563  471.3931168  470.9765241  470.7631903  470.6754141  470.5226570  470.9081843  470.9179591  471.2132904  471.2336716  471.1257224  471.1275950  470.8096231  470.8140098  472.2767152  472.4925287  472.5683947  472.6431305  472.5945978  472.6810162  472.2369496  472.1658253  474.0877068  474.1894851  474.5443833  474.6402937  474.6257787  474.4567473  474.2253319  473.9919917  476.1383963  476.8083299  476.3947121  476.0879105  478.9525119  479.1759872  479.0395571  478.5085563  483.7409637  484.6293359 
# central wavelength calculated as SAGEM (mean frequency)
#          463.0828977  463.0694572  463.0883183  463.0423975  463.0692354  462.9919500  463.0569420  461.6586784  462.1805657  462.3088211  462.0215044  461.6116058  461.3971778  461.3128520  461.1529848  461.5639048  461.5617445  461.8687498  461.8897760  461.7794850  461.7778078  461.4654384  461.4669763  462.9472232  463.1479884  463.2326480  463.3058823  463.2685706  463.3529645  462.9062139  462.8305166  464.7525916  464.8439250  465.2085407  465.3201376  465.3288912  465.1522542  464.9020579  464.6579769  466.7179199  467.4391758  467.0448363  466.6957328  469.2788516  469.6726656  469.5560332  468.9219700  476.3758299  477.3180744 
# lambda blue with 80% of peak transmission
#          410.1644712  410.1378626  410.1766702  410.1542907  410.1406724  410.1096063  410.1787939  409.1692526  409.5688741  409.6555171  409.3630693  409.0405740  408.8322749  408.8003363  408.6305431  409.2079150  409.0899062  409.4462020  409.4088431  409.2035173  409.2606957  409.0835335  409.1528368  410.3112244  410.3979790  410.4808231  410.4793750  410.4004550  410.4972186  410.2785227  410.2535307  412.0426359  412.1735009  412.5203710  412.5630891  412.5075776  412.3161403  412.1781906  411.9962216  413.5278563  414.3927825  413.5797958  413.4748244  415.7822577  415.9724902  415.9620590  415.7642294  426.1791977  427.9224643 
# lambda red  with 80% of peak transmission
#          535.5791676  535.5655956  535.5933586  535.4965320  535.5785270  535.4466939  535.5492390  534.1801846  534.5879498  534.7192700  534.4803762  534.1216739  533.9896611  533.8180983  533.6532004  534.0725026  534.1035172  534.2597680  534.2817562  534.1849357  534.2041861  533.9085040  533.9527419  535.1864326  535.4396654  535.4635439  535.5460322  535.4414807  535.5128913  535.0774311  535.0493538  537.1658098  537.2322234  537.4422156  537.4674040  537.3909590  537.2655443  537.1617063  537.0603443  538.9279904  539.5200058  538.7923780  538.7503022  541.7762652  541.2493865  540.6931628  540.9710379  520.3073835  521.3651833 
# lambda blue with 0.0001 of peak transmission
#          373.8702151  373.9531633  373.7268739  373.6396728  373.6327225  373.8910068  373.9743239  373.5008714  373.6619808  373.7372942  373.7828215  373.4444723  373.4879273  373.3505671  373.1732642  373.5268131  373.4925072  373.7324072  373.8046634  373.8009917  373.5658758  373.4801262  373.3407091  373.8321275  374.0846494  374.1652334  374.4259419  374.0365880  374.0696262  373.7648514  373.6193179  373.9231243  374.0303822  374.6028661  374.7820220  374.5543327  374.1953302  373.8286594  373.7811597  373.7715237  374.4279689  373.7414169  373.4594024  373.3850128  374.0463866  373.3073423  372.2539042  398.9172168  402.7968823 
# lambda red  with 0.0001 of peak transmission
#          600.7265663  600.5504421  600.7147646  600.6687642  600.6724430  600.4912124  600.6716005  600.1588397  600.3460269  600.2772349  600.0981884  600.1022441  600.0220578  600.0891090  599.4906578  599.9036665  599.9616484  599.9672193  599.4642260  599.5022353  599.4322695  599.3117759  599.6511876  600.0201362  600.2253416  599.5514210  599.3204878  599.4149554  599.1934697  599.0677471  599.3076158  599.5629991  599.2617746  599.2766299  598.7934181  598.6105896  598.6127914  598.8215733  599.0680800  598.3388684  597.5555238  597.0004710  598.0520904  596.4155451  595.9543341  594.9454419  595.8952653  654.7921722  609.6730400 
# ATB calculated from points above 80%
#            0.8565617    0.8554157    0.8563739    0.8556058    0.8578389    0.8578520    0.8567937    0.8523805    0.8531670    0.8537352    0.8527719    0.8510079    0.8521148    0.8556926    0.8561653    0.8482331    0.8498728    0.8480945    0.8481591    0.8484650    0.8492239    0.8523110    0.8514811    0.8452041    0.8451680    0.8454049    0.8425772    0.8415274    0.8436679    0.8434944    0.8439321    0.8426065    0.8409284    0.8401794    0.8376709    0.8393432    0.8362622    0.8388793    0.8409855    0.8348700    0.8287293    0.8267044    0.8351128    0.8247619    0.8137478    0.8129517    0.8235847    0.8763430    0.8663315 
# ATB calculated from points above 50%
#            0.8463318    0.8451842    0.8461711    0.8453283    0.8476411    0.8474977    0.8465730    0.8321387    0.8418965    0.8426320    0.8413908    0.8308879    0.8320712    0.8323350    0.8414982    0.8277164    0.8295488    0.8361793    0.8363179    0.8280316    0.8287728    0.8286772    0.8279307    0.8339823    0.8342873    0.8344572    0.8317582    0.8306356    0.8327391    0.8323144    0.8327107    0.8229167    0.8213929    0.8291783    0.8267483    0.8282955    0.8250737    0.8190891    0.8213170    0.8168411    0.8080499    0.8082499    0.8250700    0.8101420    0.7980620    0.7971588    0.7995882    0.8310256    0.8185993 
# ABR calculated from points below and above 0.0001
#            0.1479965    0.1480953    0.1478020    0.1477089    0.1473648    0.1478298    0.1473421    0.1466127    0.1444646    0.1439807    0.1446470    0.1458975    0.1467965    0.1479310    0.1493532    0.1410173    0.1381067    0.1366777    0.1376671    0.1396878    0.1411489    0.1436099    0.1439266    0.1351956    0.1308340    0.1283806    0.1294388    0.1332717    0.1362215    0.1394947    0.1399075    0.1343033    0.1273312    0.1232890    0.1253199    0.1303632    0.1367275    0.1412585    0.1407074    0.1318552    0.1272299    0.1456477    0.1494328    0.1481696    0.1391997    0.1633762    0.1721648    0.1950563    0.1683301 
# minCWL      = 470.522657 at column = 16, at id = 16 
# maxCWL      = 479.175987 at column = 46, at id = 46 
# difference =    8.6533303 
# minBW       = 132.654922 at column = 23, at id = 23 
# maxBW       = 136.135578 at column = 45, at id = 45 
# difference =    3.4806566 
# minATB80    = 0.812952 at column = 47, at id = 47 
# maxATB80    = 0.857852 at column =  7, at id =  7 
# difference =    0.0449003 
# minBlueEdge = 404.125044 at column = 16, at id = 16 
# maxBlueEdge = 411.694408 at column = 46, at id = 46 
# difference =    7.5693644 
# minRedEdge  = 536.920270 at column = 16, at id = 16 
# maxRedEdge  = 547.020301 at column = 45, at id = 45 
# difference =   10.1000310 
# minABR      = 0.123289 at column = 35, at id = 35 
# maxABR      = 0.172165 at column = 48, at id = 48 
# difference =    0.0488758 
  299.645     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.000231     0.001012    -0.000255 
  302.654     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000028     0.000206     0.000130 
  305.662     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000013     0.000095    -0.000011 
  308.671     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000040     0.000011    -0.000026 
  311.679     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000048     0.000052     0.000037 
  314.687     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000017     0.000007     0.000007 
  317.694     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000011     0.000010     0.000010 
  320.702     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000012     0.000040     0.000001 
  323.709     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000001     0.000014 
  326.716     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000012     0.000001 
  329.665     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000020     0.000000 
  332.672     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000006     0.000013    -0.000002 
  335.678     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000004     0.000002 
  338.683     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000013    -0.000001 
  341.689     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000008     0.000000     0.000003 
  344.694     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007     0.000007    -0.000001     0.000003 
  347.699     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005     0.000005    -0.000003    -0.000004 
  350.703     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001    -0.000001 
  353.707     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000003     0.000000 
  356.711     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000003    -0.000002 
  359.715     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000002     0.000004 
  362.718     0.000004     0.000002     0.000006     0.000004     0.000006     0.000006     0.000003     0.000005     0.000004     0.000006     0.000003     0.000002     0.000004     0.000002     0.000009     0.000004     0.000005     0.000002    -0.000000     0.000002    -0.000002     0.000008     0.000011     0.000005     0.000007     0.000004    -0.000003     0.000004     0.000002     0.000006    -0.000001     0.000005    -0.000001     0.000000     0.000001    -0.000001     0.000002     0.000002    -0.000003     0.000006     0.000002     0.000006     0.000003     0.000001    -0.000003     0.000003     0.000001     0.000003     0.000000 
  365.721     0.000007     0.000006     0.000005     0.000003     0.000006     0.000008     0.000003     0.000005     0.000002     0.000002     0.000003     0.000007     0.000004     0.000009     0.000006     0.000004     0.000004     0.000006     0.000004    -0.000002     0.000003     0.000007     0.000008     0.000006     0.000005     0.000001     0.000002     0.000005     0.000000    -0.000001     0.000003     0.000006    -0.000002     0.000003    -0.000001    -0.000003     0.000004     0.000001    -0.000000     0.000001    -0.000004     0.000006     0.000003     0.000001    -0.000002    -0.000002     0.000005     0.000003     0.000001 
  368.724     0.000005     0.000004     0.000003     0.000003     0.000009     0.000005     0.000001     0.000004     0.000003     0.000001    -0.000002     0.000007    -0.000001     0.000002     0.000008     0.000003     0.000004     0.000003     0.000006     0.000003     0.000002     0.000004     0.000008     0.000007     0.000005     0.000003    -0.000001    -0.000002    -0.000001     0.000001     0.000002     0.000002     0.000001     0.000002    -0.000001    -0.000001     0.000003     0.000003     0.000004     0.000005     0.000004     0.000002     0.000007     0.000004    -0.000002     0.000001     0.000006     0.000001     0.000002 
  371.726     0.000006     0.000004     0.000003     0.000003     0.000006     0.000006     0.000002     0.000005     0.000005     0.000003     0.000005     0.000007     0.000005     0.000002     0.000006     0.000005     0.000005     0.000002     0.000003     0.000001     0.000002     0.000005     0.000008     0.000009     0.000004     0.000002     0.000004     0.000004     0.000003     0.000002     0.000007     0.000006     0.000001     0.000002    -0.000000     0.000000     0.000001     0.000003     0.000003     0.000005     0.000002     0.000005     0.000005    -0.000000    -0.000000     0.000041     0.000067     0.000000     0.000002 
  374.728     0.000125     0.000121     0.000135     0.000141     0.000140     0.000124     0.000121     0.000150     0.000138     0.000134     0.000130     0.000153     0.000151     0.000166     0.000182     0.000147     0.000150     0.000134     0.000129     0.000130     0.000146     0.000151     0.000161     0.000124     0.000113     0.000110     0.000099     0.000115     0.000114     0.000131     0.000138     0.000120     0.000116     0.000093     0.000086     0.000095     0.000108     0.000126     0.000129     0.000128     0.000098     0.000129     0.000150     0.000159     0.000113     0.000130     0.000189     0.000005     0.000002 
  377.730     0.000567     0.000561     0.000529     0.000567     0.000543     0.000548     0.000571     0.000751     0.000640     0.000597     0.000682     0.000744     0.000788     0.000822     0.000880     0.000747     0.000703     0.000620     0.000611     0.000646     0.000691     0.000768     0.000777     0.000524     0.000453     0.000405     0.000404     0.000419     0.000465     0.000537     0.000550     0.000370     0.000325     0.000274     0.000258     0.000277     0.000317     0.000372     0.000397     0.000288     0.000220     0.000273     0.000337     0.000290     0.000246     0.000273     0.000343     0.000006     0.000002 
  380.788     0.001638     0.001637     0.001636     0.001645     0.001657     0.001675     0.001645     0.002127     0.001934     0.001894     0.001978     0.002096     0.002180     0.002188     0.002253     0.002109     0.002081     0.001960     0.001952     0.001989     0.001986     0.002086     0.002109     0.001621     0.001516     0.001425     0.001387     0.001428     0.001424     0.001571     0.001631     0.001062     0.001035     0.000887     0.000825     0.000842     0.000924     0.000998     0.001101     0.000673     0.000498     0.000613     0.000723     0.000485     0.000432     0.000425     0.000548     0.000009     0.000004 
  383.789     0.002082     0.002078     0.002069     0.002087     0.002082     0.002103     0.002082     0.002417     0.002322     0.002274     0.002324     0.002386     0.002439     0.002434     0.002435     0.002493     0.002446     0.002442     0.002417     0.002400     0.002371     0.002445     0.002459     0.002312     0.002212     0.002191     0.002119     0.002105     0.002041     0.002167     0.002219     0.001933     0.001882     0.001771     0.001655     0.001635     0.001612     0.001700     0.001815     0.001378     0.001101     0.001103     0.001332     0.000891     0.000766     0.000697     0.000911     0.000027     0.000004 
  386.789     0.002493     0.002495     0.002488     0.002529     0.002530     0.002544     0.002513     0.003106     0.002839     0.002722     0.002837     0.003051     0.003179     0.003277     0.003463     0.003186     0.003105     0.002870     0.002854     0.002926     0.003018     0.003259     0.003318     0.002727     0.002524     0.002374     0.002320     0.002372     0.002459     0.002749     0.002834     0.002492     0.002302     0.002052     0.001941     0.002017     0.002174     0.002404     0.002538     0.002191     0.001721     0.002056     0.002427     0.001966     0.001553     0.001708     0.002228     0.000032     0.000005 
  389.790     0.006365     0.006420     0.006366     0.006483     0.006427     0.006570     0.006418     0.009139     0.007943     0.007551     0.008096     0.008985     0.009549     0.009926     0.010523     0.009301     0.009126     0.008251     0.008104     0.008400     0.008515     0.009431     0.009596     0.006593     0.006120     0.005680     0.005446     0.005524     0.005583     0.006550     0.006825     0.004756     0.004494     0.003927     0.003689     0.003712     0.003974     0.004454     0.004831     0.003788     0.002920     0.003218     0.003940     0.003583     0.002789     0.002935     0.003758     0.000038     0.000005 
  392.790     0.019050     0.019114     0.018957     0.019381     0.019127     0.019697     0.019165     0.030068     0.025493     0.024417     0.026632     0.030009     0.032049     0.033011     0.034450     0.030444     0.029943     0.027282     0.026830     0.027565     0.027711     0.030564     0.030893     0.019265     0.017555     0.016658     0.015829     0.015956     0.015680     0.018777     0.019655     0.011039     0.010458     0.009147     0.008443     0.008328     0.008923     0.010048     0.011113     0.006852     0.005059     0.005481     0.006934     0.005297     0.004004     0.004033     0.005390     0.000055     0.000003 
  395.790     0.052901     0.052906     0.052559     0.053438     0.052947     0.054314     0.052995     0.077184     0.067735     0.065434     0.070256     0.076965     0.080916     0.082673     0.085133     0.077549     0.076776     0.071418     0.070501     0.071639     0.071918     0.077179     0.077957     0.053249     0.049115     0.046640     0.044545     0.044920     0.043972     0.051211     0.053563     0.030578     0.028748     0.024817     0.022877     0.022667     0.024164     0.027108     0.030327     0.016123     0.011365     0.012628     0.016361     0.009424     0.006853     0.006944     0.009926     0.000065     0.000022 
  398.789     0.111269     0.111358     0.111110     0.112075     0.111779     0.113666     0.111729     0.146546     0.133291     0.129929     0.136793     0.146581     0.152133     0.154918     0.157877     0.146606     0.146117     0.138912     0.137144     0.138248     0.138515     0.146177     0.147560     0.110642     0.105563     0.100873     0.097467     0.097173     0.095820     0.106974     0.111167     0.075756     0.072482     0.063157     0.059019     0.058830     0.061578     0.067661     0.074211     0.044927     0.031530     0.035556     0.044947     0.023883     0.017151     0.017498     0.025861     0.000091     0.000040 
  401.788     0.195964     0.196349     0.196155     0.197701     0.197437     0.200443     0.197494     0.257981     0.234685     0.228887     0.241665     0.259433     0.269261     0.274199     0.279523     0.258502     0.259313     0.247164     0.244765     0.246769     0.246580     0.260422     0.262377     0.194716     0.187654     0.182636     0.177258     0.174411     0.172335     0.192015     0.198366     0.140888     0.137284     0.124642     0.117359     0.115069     0.119178     0.129578     0.139757     0.100642     0.075467     0.081734     0.099192     0.066410     0.048939     0.050103     0.069965     0.000138     0.000071 
  404.787     0.368384     0.369107     0.368632     0.371368     0.371214     0.376021     0.371631     0.465955     0.431419     0.422325     0.442480     0.468442     0.483897     0.489228     0.503738     0.465660     0.468868     0.446006     0.444460     0.452078     0.453285     0.473179     0.473345     0.362718     0.350382     0.341859     0.334412     0.332711     0.329687     0.365159     0.372907     0.255339     0.250532     0.229951     0.218298     0.213182     0.222842     0.242046     0.258873     0.182684     0.142041     0.150973     0.180488     0.140639     0.106922     0.108989     0.142594     0.000259     0.000135 
  407.785     0.612328     0.612441     0.611911     0.614317     0.614890     0.618534     0.614450     0.684170     0.661895     0.656135     0.672064     0.688024     0.697413     0.699166     0.705993     0.678797     0.684047     0.667568     0.668993     0.676723     0.675189     0.685325     0.683025     0.593893     0.583435     0.577504     0.571829     0.574523     0.567948     0.597473     0.601196     0.462588     0.457824     0.431195     0.419002     0.414668     0.427492     0.449408     0.467758     0.338137     0.273498     0.291749     0.334617     0.249486     0.195339     0.197879     0.252369     0.000641     0.000362 
  410.783     0.758040     0.757662     0.757228     0.757866     0.759964     0.760744     0.757904     0.774389     0.769917     0.768343     0.772917     0.775389     0.777874     0.778411     0.779756     0.768672     0.772609     0.765414     0.766793     0.770981     0.770374     0.771118     0.769244     0.740523     0.736823     0.733783     0.731723     0.736095     0.732983     0.741059     0.741788     0.676251     0.671708     0.654640     0.649572     0.652685     0.657178     0.666923     0.676885     0.568254     0.504677     0.531458     0.562579     0.432954     0.369089     0.374401     0.442509     0.001304     0.000872 
  413.781     0.793015     0.791593     0.792831     0.791848     0.794684     0.793878     0.792519     0.786290     0.787421     0.788696     0.788092     0.786544     0.786709     0.786750     0.786197     0.780893     0.781429     0.780431     0.780760     0.784781     0.784785     0.782824     0.782155     0.777991     0.777593     0.776144     0.774502     0.778107     0.779524     0.779115     0.779412     0.769620     0.763337     0.756475     0.755995     0.762810     0.764601     0.766391     0.768782     0.723602     0.693895     0.718543     0.726548     0.621326     0.591539     0.602375     0.634273     0.003560     0.002010 
  416.834     0.796671     0.795858     0.796749     0.795377     0.798855     0.797407     0.796732     0.786766     0.789264     0.791526     0.790910     0.788239     0.787739     0.788118     0.784440     0.780405     0.783519     0.783985     0.783696     0.785308     0.783537     0.781885     0.779959     0.774664     0.780836     0.781007     0.779250     0.778456     0.777678     0.774628     0.774214     0.774408     0.771894     0.776516     0.775885     0.778238     0.774145     0.772600     0.771981     0.766895     0.760507     0.768647     0.765151     0.745851     0.740888     0.743305     0.747200     0.018707     0.008875 
  419.831     0.786877     0.786058     0.786642     0.785714     0.788805     0.788323     0.786851     0.787992     0.786227     0.787219     0.787862     0.787983     0.790042     0.790857     0.791303     0.781975     0.784800     0.782805     0.783311     0.784263     0.783938     0.784179     0.783051     0.767651     0.772909     0.774410     0.771432     0.767945     0.768226     0.769309     0.769099     0.765144     0.767710     0.771506     0.767907     0.766360     0.763272     0.763855     0.764873     0.772529     0.767830     0.766421     0.770312     0.769447     0.765903     0.773168     0.774725     0.077005     0.044333 
  422.828     0.816292     0.816013     0.816054     0.815875     0.817967     0.818109     0.816599     0.824586     0.819894     0.819105     0.821341     0.822881     0.827389     0.828989     0.832049     0.819992     0.822260     0.815665     0.814964     0.818554     0.821062     0.824467     0.822842     0.801381     0.802955     0.797977     0.794367     0.794562     0.798055     0.804826     0.805122     0.784583     0.784092     0.777717     0.774680     0.774362     0.778430     0.784698     0.787583     0.776600     0.760673     0.768639     0.778269     0.765969     0.750328     0.749907     0.758964     0.282165     0.161699 
  425.824     0.833840     0.832744     0.833169     0.833288     0.835699     0.835162     0.834031     0.837541     0.836700     0.836391     0.838122     0.836948     0.839431     0.839887     0.837927     0.833621     0.836922     0.834756     0.834142     0.834704     0.834576     0.834699     0.833407     0.821365     0.824134     0.823946     0.819020     0.816248     0.814819     0.818527     0.819839     0.801287     0.802284     0.801326     0.794927     0.790237     0.787178     0.792272     0.797514     0.775674     0.758687     0.751044     0.766751     0.773233     0.761188     0.759808     0.762960     0.729944     0.557834 
  428.820     0.826001     0.825253     0.824995     0.825570     0.828473     0.827263     0.826813     0.823604     0.824125     0.823565     0.824098     0.821745     0.823779     0.824937     0.827947     0.819255     0.821135     0.818015     0.818801     0.820629     0.822090     0.822531     0.820840     0.814966     0.813505     0.814739     0.811361     0.811366     0.813502     0.814245     0.814721     0.812453     0.813283     0.809815     0.806035     0.807837     0.806313     0.808542     0.811024     0.816554     0.798755     0.799200     0.807746     0.787550     0.772823     0.766635     0.785409     0.849137     0.818257 
  431.815     0.856083     0.854862     0.854766     0.854971     0.857649     0.857045     0.856261     0.852459     0.852195     0.852220     0.852510     0.850955     0.853413     0.854354     0.857405     0.847573     0.849497     0.844877     0.844912     0.848841     0.849228     0.850321     0.848854     0.841053     0.840739     0.838127     0.834764     0.837026     0.840931     0.842183     0.842667     0.836762     0.831573     0.828733     0.826302     0.830527     0.833869     0.837507     0.838677     0.822395     0.807340     0.823447     0.830930     0.814758     0.796141     0.811103     0.823247     0.877508     0.863351 
  434.810     0.852975     0.852266     0.851932     0.851361     0.854275     0.854152     0.852955     0.849279     0.850997     0.850876     0.850874     0.849579     0.851070     0.850872     0.851013     0.844355     0.847449     0.845526     0.845415     0.848427     0.847787     0.847387     0.844784     0.839017     0.838998     0.840333     0.837822     0.838591     0.839937     0.837626     0.837507     0.837046     0.836070     0.835291     0.834172     0.837279     0.835389     0.835421     0.835798     0.836113     0.825371     0.826556     0.836455     0.815731     0.802302     0.804473     0.819408     0.844296     0.841335 
  437.862     0.846841     0.845643     0.845937     0.845333     0.847766     0.848384     0.846285     0.844890     0.844547     0.843177     0.843392     0.841338     0.845196     0.846674     0.847150     0.840981     0.842977     0.838012     0.837172     0.841322     0.843158     0.844878     0.843253     0.837693     0.836286     0.832996     0.829579     0.830792     0.835972     0.836421     0.837458     0.834569     0.829288     0.825062     0.821601     0.825555     0.827895     0.831858     0.834396     0.825122     0.812256     0.819106     0.828741     0.834162     0.826081     0.826054     0.829854     0.832685     0.809751 
  440.856     0.846984     0.845802     0.845997     0.844698     0.847309     0.847779     0.846732     0.844626     0.844346     0.842491     0.841829     0.840672     0.843547     0.845958     0.847853     0.839120     0.840635     0.835557     0.835894     0.839569     0.841740     0.843808     0.841947     0.836688     0.833178     0.833189     0.830356     0.830834     0.836375     0.836588     0.837709     0.837580     0.832760     0.830024     0.828242     0.832184     0.834054     0.836374     0.839190     0.836010     0.827366     0.833077     0.839728     0.825296     0.815326     0.818506     0.827454     0.880024     0.843262 
  443.850     0.868435     0.867397     0.867218     0.866618     0.868880     0.869567     0.867911     0.866015     0.864854     0.863547     0.862992     0.863020     0.865065     0.867129     0.868953     0.859933     0.863817     0.856114     0.856941     0.860804     0.862473     0.865031     0.862923     0.855188     0.854065     0.850626     0.848763     0.849339     0.855567     0.856208     0.856801     0.850944     0.845761     0.841817     0.840199     0.845055     0.846811     0.849445     0.851788     0.838504     0.827578     0.832033     0.839966     0.825750     0.812789     0.803829     0.816376     0.844976     0.869089 
  446.844     0.861223     0.860819     0.860905     0.859734     0.861572     0.862465     0.860907     0.858113     0.858709     0.857179     0.855137     0.854994     0.856546     0.857360     0.857013     0.851266     0.852873     0.849368     0.849725     0.853258     0.854498     0.855781     0.853790     0.845816     0.843184     0.844363     0.842424     0.842179     0.847812     0.847457     0.847427     0.841218     0.836052     0.835916     0.833405     0.837660     0.838785     0.840945     0.842486     0.824168     0.814933     0.819614     0.828766     0.795872     0.780077     0.774258     0.791717     0.778027     0.790223 
  449.837     0.849077     0.848931     0.849509     0.848912     0.849351     0.851265     0.848540     0.847318     0.847433     0.844655     0.841790     0.842043     0.843746     0.846001     0.846320     0.841604     0.844029     0.837483     0.835728     0.840934     0.843453     0.846111     0.845162     0.837271     0.834455     0.832505     0.830358     0.830590     0.838344     0.839879     0.840128     0.831995     0.824734     0.823116     0.819367     0.823675     0.826613     0.830872     0.833993     0.812872     0.800625     0.806699     0.815648     0.805572     0.790596     0.786923     0.800728     0.806291     0.779609 
  452.830     0.850638     0.850512     0.851720     0.849750     0.851068     0.852441     0.850443     0.848355     0.848413     0.846231     0.844092     0.844595     0.845720     0.848010     0.849711     0.842891     0.845532     0.838723     0.838596     0.843445     0.845530     0.847289     0.846473     0.839551     0.836707     0.834636     0.833906     0.833977     0.840938     0.841101     0.841628     0.837636     0.834451     0.831043     0.829724     0.832525     0.835707     0.836655     0.839936     0.833031     0.821505     0.826976     0.832140     0.810552     0.788543     0.772400     0.798497     0.873084     0.846633 
  455.878     0.861938     0.861211     0.862830     0.861334     0.862708     0.863759     0.861127     0.860347     0.859877     0.858862     0.858629     0.857953     0.859204     0.860281     0.859346     0.855828     0.859333     0.855063     0.853420     0.857711     0.857596     0.857880     0.856244     0.850201     0.850315     0.850869     0.848662     0.846401     0.850602     0.848562     0.849345     0.843131     0.841487     0.842865     0.838685     0.839321     0.836663     0.837850     0.841831     0.818879     0.808704     0.799467     0.816201     0.781058     0.763519     0.760742     0.782237     0.853212     0.862680 
  458.870     0.851853     0.851200     0.852005     0.851098     0.853183     0.853803     0.850937     0.852310     0.849895     0.849654     0.850177     0.849714     0.851283     0.853032     0.851036     0.848885     0.850914     0.845052     0.843097     0.847814     0.848116     0.849578     0.849184     0.839383     0.840343     0.835530     0.832623     0.833221     0.837158     0.837773     0.839341     0.827512     0.823162     0.820377     0.817125     0.819318     0.818832     0.822446     0.827300     0.806547     0.795317     0.801926     0.812111     0.810079     0.795043     0.802681     0.813838     0.848444     0.827457 
  461.862     0.868455     0.867003     0.868522     0.867942     0.869833     0.869871     0.867696     0.867690     0.865381     0.867528     0.868658     0.868710     0.869211     0.869440     0.868858     0.862411     0.864868     0.862578     0.862669     0.865214     0.863894     0.863040     0.861532     0.852485     0.856188     0.852717     0.850786     0.851250     0.851757     0.849943     0.850882     0.844323     0.845275     0.841655     0.841797     0.843061     0.839462     0.839636     0.842794     0.834370     0.826639     0.828735     0.836476     0.811062     0.800128     0.801571     0.815068     0.883721     0.858811 
  464.853     0.879783     0.878195     0.879934     0.879124     0.881634     0.881027     0.879406     0.877777     0.876670     0.878793     0.879730     0.879136     0.878124     0.878618     0.874794     0.872388     0.876233     0.876050     0.874798     0.875162     0.872803     0.871884     0.870007     0.862620     0.867945     0.866572     0.863895     0.862362     0.861079     0.858447     0.859508     0.850394     0.851628     0.852466     0.850089     0.849734     0.842642     0.844218     0.846919     0.826858     0.822478     0.818173     0.827755     0.823813     0.821654     0.829819     0.827889     0.906818     0.884816 
  467.901     0.847445     0.845860     0.847771     0.847032     0.849674     0.848814     0.847150     0.844450     0.843747     0.847083     0.847951     0.846328     0.845795     0.845170     0.841030     0.840093     0.839853     0.844006     0.843741     0.842589     0.841083     0.839396     0.837449     0.832031     0.834246     0.838688     0.835844     0.833046     0.831784     0.829279     0.829454     0.827624     0.829112     0.832918     0.832626     0.830839     0.824797     0.825394     0.827160     0.834913     0.834515     0.839093     0.838260     0.864924     0.860564     0.865323     0.867368     0.917419     0.908552 
  470.891     0.863610     0.861086     0.863092     0.862169     0.865014     0.865025     0.862148     0.859313     0.858143     0.860340     0.860271     0.859789     0.860826     0.860601     0.864062     0.855107     0.855467     0.853560     0.855780     0.856959     0.857997     0.857832     0.854965     0.850108     0.850539     0.851088     0.850870     0.850994     0.854584     0.851945     0.851833     0.856704     0.857441     0.855356     0.857825     0.859794     0.856819     0.858287     0.859578     0.868145     0.863461     0.865572     0.871104     0.873728     0.865646     0.861568     0.870626     0.927014     0.914000 
  473.881     0.884818     0.882507     0.884465     0.883727     0.885567     0.886687     0.883489     0.881987     0.880818     0.881826     0.881410     0.880806     0.882203     0.882624     0.882913     0.877955     0.877205     0.875887     0.876694     0.877207     0.878020     0.878917     0.877688     0.871098     0.869535     0.870619     0.868503     0.868075     0.870332     0.869462     0.871093     0.869566     0.866903     0.867633     0.865681     0.866916     0.864053     0.866780     0.870107     0.864515     0.859925     0.862214     0.870020     0.863202     0.854297     0.864771     0.870289     0.923066     0.925300 
  476.871     0.889777     0.888011     0.889628     0.888761     0.891049     0.892603     0.888635     0.888188     0.886627     0.888315     0.888320     0.887515     0.889187     0.889138     0.889462     0.883985     0.884128     0.883515     0.884071     0.884253     0.885047     0.884828     0.883743     0.876520     0.875842     0.876552     0.874062     0.875029     0.876154     0.875646     0.875438     0.873431     0.871830     0.870103     0.869549     0.872870     0.869509     0.870223     0.872460     0.867812     0.861074     0.864589     0.870447     0.866212     0.855595     0.859721     0.867166     0.886380     0.884000 
  479.916     0.886505     0.884626     0.886456     0.885154     0.887913     0.889807     0.885942     0.885223     0.884219     0.886186     0.884999     0.885249     0.886211     0.886149     0.885759     0.880312     0.881228     0.881842     0.882519     0.881875     0.882860     0.882275     0.880738     0.873721     0.872770     0.875210     0.872420     0.872234     0.873143     0.872786     0.872003     0.869112     0.866102     0.867792     0.865354     0.867966     0.864591     0.865511     0.867910     0.863764     0.855951     0.861808     0.867210     0.870328     0.859129     0.869616     0.874288     0.898877     0.875521 
  482.905     0.888095     0.886584     0.888063     0.886896     0.889848     0.891407     0.887846     0.887302     0.885537     0.887130     0.885751     0.886461     0.887329     0.888113     0.889801     0.883325     0.882226     0.881589     0.882208     0.882543     0.884695     0.885531     0.883993     0.879034     0.876473     0.876636     0.874218     0.875234     0.877903     0.878456     0.877831     0.878282     0.874333     0.873322     0.870834     0.876660     0.873509     0.875072     0.876751     0.878085     0.868485     0.872383     0.876267     0.873853     0.866974     0.864293     0.870134     0.904203     0.890498 
  485.894     0.886730     0.885582     0.886548     0.885868     0.888743     0.889480     0.887060     0.885886     0.885086     0.886215     0.885101     0.884717     0.885747     0.886025     0.887437     0.881511     0.881266     0.881636     0.881492     0.881214     0.882208     0.883347     0.881686     0.877090     0.874631     0.877542     0.874798     0.873663     0.874890     0.875018     0.874956     0.874195     0.871922     0.875593     0.871397     0.873734     0.868634     0.870370     0.872238     0.870595     0.863682     0.863707     0.870088     0.869349     0.863181     0.869736     0.875132     0.911742     0.896531 
  488.882     0.893334     0.892734     0.893108     0.892254     0.895756     0.896064     0.894452     0.892955     0.890861     0.892309     0.891506     0.891988     0.893092     0.893582     0.895787     0.888177     0.887878     0.886633     0.886953     0.887621     0.889480     0.891497     0.890263     0.883108     0.882169     0.880555     0.878070     0.879843     0.883037     0.884957     0.883581     0.882064     0.878271     0.876181     0.875152     0.881522     0.880624     0.882067     0.883480     0.881908     0.872303     0.880643     0.884495     0.878691     0.873430     0.872245     0.876667     0.894167     0.897019 
  491.925     0.906567     0.905671     0.906274     0.906014     0.909339     0.909149     0.908289     0.905085     0.905095     0.905734     0.904281     0.904324     0.904649     0.905120     0.907073     0.899118     0.901160     0.900674     0.900984     0.898941     0.899730     0.900825     0.900587     0.892879     0.892094     0.895597     0.891522     0.891005     0.892288     0.891798     0.891348     0.886789     0.885864     0.889379     0.886794     0.889827     0.883667     0.884112     0.885288     0.878093     0.875614     0.870905     0.878003     0.863804     0.864174     0.865296     0.870408     0.874117     0.860967 
  494.913     0.905198     0.903813     0.904973     0.904744     0.907174     0.907297     0.906962     0.902948     0.902749     0.903351     0.902767     0.902639     0.903400     0.904054     0.904957     0.896948     0.897585     0.897655     0.897930     0.897757     0.898485     0.899182     0.898911     0.889845     0.888323     0.891053     0.887841     0.887987     0.890645     0.891337     0.890944     0.884884     0.881600     0.881618     0.880698     0.885684     0.883587     0.886095     0.887002     0.878912     0.871930     0.882484     0.886820     0.874345     0.870344     0.878819     0.884538     0.902547     0.879689 
  497.899     0.909972     0.908015     0.909798     0.909703     0.911102     0.911002     0.911241     0.907283     0.907713     0.907680     0.906438     0.905766     0.906900     0.907505     0.908496     0.901817     0.903243     0.902231     0.902457     0.901652     0.902552     0.903106     0.902953     0.896811     0.896405     0.897539     0.894412     0.894348     0.896564     0.896122     0.896198     0.894351     0.892758     0.892068     0.890952     0.895042     0.890141     0.891516     0.892592     0.888106     0.884054     0.879789     0.887253     0.874652     0.873169     0.866048     0.875061     0.915410     0.902165 
  500.942     0.904489     0.902613     0.903965     0.904335     0.905135     0.905642     0.905709     0.901180     0.902106     0.901964     0.900716     0.900293     0.901410     0.901196     0.900708     0.895567     0.896704     0.897105     0.896682     0.895344     0.896099     0.895481     0.895983     0.889550     0.889322     0.891002     0.888293     0.887123     0.888101     0.886787     0.886834     0.884657     0.883139     0.884742     0.882559     0.884621     0.877418     0.879278     0.880726     0.876030     0.872832     0.864380     0.874223     0.866943     0.857805     0.847523     0.861735     0.930094     0.914350 
  503.928     0.892506     0.890453     0.891865     0.892119     0.893279     0.893497     0.893905     0.888562     0.890711     0.890981     0.889350     0.887312     0.888553     0.887192     0.886029     0.883017     0.884607     0.886467     0.885830     0.882052     0.882036     0.880013     0.881593     0.876851     0.876715     0.880159     0.876702     0.872956     0.871537     0.869385     0.870282     0.872405     0.872879     0.873647     0.869351     0.870051     0.858240     0.860574     0.863766     0.864601     0.859746     0.845408     0.856119     0.853147     0.841606     0.833795     0.848592     0.904614     0.916178 
  506.913     0.873621     0.872098     0.873019     0.873580     0.874763     0.875019     0.875198     0.869819     0.872305     0.872195     0.871446     0.868979     0.870459     0.869007     0.869138     0.864995     0.866433     0.867323     0.867626     0.863974     0.864442     0.863381     0.863755     0.859770     0.859064     0.862071     0.859032     0.855402     0.856004     0.854918     0.855667     0.857475     0.855153     0.855398     0.850952     0.854858     0.848193     0.852822     0.853341     0.849557     0.844182     0.852260     0.857919     0.855594     0.842802     0.859635     0.869004     0.858082     0.861739 
  509.954     0.880608     0.879302     0.879947     0.880267     0.881428     0.881525     0.882000     0.877200     0.878217     0.878143     0.879074     0.877849     0.879452     0.878185     0.881938     0.874887     0.876679     0.873606     0.875553     0.874633     0.876505     0.876411     0.875987     0.872410     0.869592     0.869643     0.869268     0.869769     0.873396     0.873537     0.872205     0.874913     0.869387     0.863164     0.864265     0.873704     0.869910     0.874816     0.874161     0.869989     0.863549     0.866335     0.872748     0.863374     0.852923     0.807977     0.826171     0.874497     0.848798 
  512.939     0.895199     0.894372     0.894964     0.894768     0.895720     0.896316     0.896542     0.890586     0.892853     0.892858     0.892839     0.891198     0.892308     0.890952     0.892952     0.887943     0.889643     0.889145     0.890657     0.887110     0.887167     0.886897     0.887056     0.883201     0.882802     0.887009     0.884945     0.879574     0.879403     0.877963     0.878116     0.875280     0.874948     0.877213     0.872925     0.871773     0.858338     0.860789     0.864297     0.850258     0.847115     0.811398     0.826730     0.792065     0.778253     0.717387     0.743769     0.896433     0.880774 
  515.923     0.895343     0.894322     0.895477     0.894542     0.896067     0.896148     0.896691     0.888653     0.891620     0.892138     0.890945     0.888533     0.888973     0.888642     0.889359     0.883116     0.885944     0.886136     0.887102     0.882121     0.882049     0.882074     0.882012     0.873758     0.874736     0.879461     0.876024     0.870129     0.870156     0.869858     0.869633     0.854103     0.854430     0.856804     0.851103     0.847426     0.840627     0.845385     0.847735     0.811131     0.799863     0.795974     0.805663     0.747024     0.722420     0.733717     0.749082     0.875985     0.878189 
  518.963     0.875816     0.875289     0.876293     0.874874     0.876931     0.876972     0.877109     0.868556     0.872797     0.873924     0.870606     0.866857     0.866549     0.866737     0.865175     0.869544     0.870854     0.872299     0.872167     0.866499     0.866990     0.866732     0.867137     0.873242     0.874194     0.877202     0.873524     0.868000     0.869420     0.869443     0.869896     0.865922     0.866058     0.861244     0.858736     0.859107     0.856986     0.863383     0.864489     0.831197     0.815622     0.833662     0.838753     0.784035     0.767067     0.804087     0.806326     0.794881     0.827784 
  521.946     0.816615     0.816427     0.817476     0.816310     0.817546     0.818589     0.817654     0.810900     0.815581     0.815640     0.811315     0.806953     0.807188     0.808492     0.805444     0.820254     0.819994     0.822302     0.819125     0.813300     0.813972     0.815306     0.816301     0.842718     0.843177     0.846944     0.840204     0.831776     0.833195     0.833849     0.836174     0.857932     0.860355     0.859839     0.854404     0.849799     0.843327     0.850330     0.853132     0.851409     0.843684     0.844288     0.852766     0.835422     0.825332     0.845304     0.850700     0.682150     0.719073 
  524.929     0.788125     0.787790     0.788933     0.787256     0.789377     0.789277     0.789128     0.782881     0.783948     0.785083     0.782316     0.779702     0.782225     0.783065     0.784093     0.790741     0.789304     0.787029     0.785815     0.783249     0.785877     0.787885     0.789260     0.810776     0.809155     0.809349     0.804279     0.799319     0.803265     0.804841     0.806737     0.833860     0.835091     0.834585     0.829222     0.825402     0.821465     0.828570     0.831817     0.850630     0.841597     0.838655     0.850770     0.861101     0.845099     0.854027     0.866672     0.647446     0.640328 
  527.967     0.820029     0.818895     0.820497     0.818450     0.821242     0.817858     0.821151     0.816147     0.815311     0.816685     0.815193     0.812750     0.816736     0.817480     0.822128     0.817605     0.818547     0.811119     0.811709     0.810233     0.813406     0.815111     0.817023     0.822921     0.821637     0.817380     0.812814     0.811100     0.815526     0.818342     0.820141     0.833200     0.833710     0.827799     0.824242     0.821879     0.821258     0.829174     0.833095     0.846760     0.832669     0.829959     0.845968     0.864361     0.849301     0.849170     0.859749     0.699911     0.663223 
  530.949     0.847767     0.846185     0.847723     0.845661     0.848224     0.845267     0.848054     0.834053     0.839574     0.841880     0.837971     0.829536     0.830429     0.828910     0.830297     0.830608     0.832945     0.830118     0.830151     0.826594     0.827657     0.824312     0.826298     0.840308     0.839446     0.836935     0.832002     0.829175     0.830067     0.831005     0.834241     0.840113     0.839621     0.834592     0.829472     0.826925     0.824206     0.831180     0.837142     0.839774     0.826281     0.820937     0.836097     0.837021     0.824901     0.815839     0.830728     0.737044     0.716108 
  533.987     0.818995     0.816814     0.819001     0.815176     0.819242     0.814570     0.818924     0.742002     0.771718     0.780204     0.763883     0.735836     0.725749     0.719946     0.714021     0.728786     0.732531     0.743990     0.745960     0.737534     0.739869     0.719784     0.721177     0.796279     0.803801     0.805019     0.803668     0.799688     0.802071     0.787100     0.786990     0.831069     0.829237     0.828123     0.824833     0.824489     0.818818     0.821795     0.824833     0.821287     0.807544     0.800967     0.819319     0.793418     0.783829     0.777156     0.793031     0.729050     0.714264 
  536.968     0.648584     0.646100     0.649826     0.642553     0.649993     0.639413     0.647321     0.492399     0.545780     0.560131     0.529859     0.487411     0.469217     0.460930     0.450021     0.473146     0.478311     0.501316     0.503294     0.493368     0.495178     0.465008     0.466167     0.600359     0.625932     0.629399     0.635140     0.627098     0.636366     0.595182     0.590479     0.730856     0.734022     0.746719     0.747042     0.745621     0.733398     0.727612     0.721256     0.780686     0.776227     0.765847     0.778119     0.772208     0.763884     0.754672     0.770178     0.709192     0.692003 
  539.948     0.378675     0.377769     0.380189     0.374652     0.380179     0.370126     0.377260     0.245755     0.286031     0.297099     0.273532     0.243182     0.230470     0.224858     0.218094     0.232106     0.235633     0.252998     0.253836     0.247075     0.248024     0.227872     0.228102     0.331971     0.357313     0.363139     0.369332     0.361017     0.371330     0.329320     0.323493     0.499229     0.510535     0.538939     0.542487     0.537160     0.520220     0.506093     0.489476     0.673951     0.695674     0.668070     0.663894     0.744921     0.731559     0.720164     0.737036     0.644496     0.648824 
  542.984     0.181285     0.180772     0.181900     0.179170     0.181732     0.176198     0.180001     0.111618     0.130987     0.136922     0.125297     0.110614     0.104540     0.101953     0.098690     0.104632     0.106166     0.114819     0.115076     0.111615     0.111967     0.102764     0.102678     0.153996     0.167576     0.171621     0.174501     0.169629     0.175488     0.152563     0.148912     0.261714     0.270512     0.295084     0.297734     0.290820     0.280323     0.268335     0.254966     0.453240     0.491579     0.452146     0.441665     0.675229     0.655005     0.650458     0.649771     0.495442     0.536036 
  545.964     0.084853     0.084457     0.084997     0.083703     0.084871     0.082447     0.084067     0.053506     0.061961     0.064831     0.059490     0.052956     0.050308     0.049163     0.047543     0.050095     0.050612     0.054704     0.054601     0.053003     0.053196     0.049141     0.049007     0.071714     0.077806     0.079792     0.080666     0.078003     0.080818     0.070535     0.069000     0.122077     0.127003     0.139295     0.140071     0.134952     0.130558     0.124254     0.118341     0.239192     0.268562     0.236584     0.229816     0.518574     0.487474     0.473937     0.461807     0.292491     0.349210 
  548.999     0.040986     0.040725     0.041032     0.040404     0.040974     0.039870     0.040560     0.027040     0.030718     0.032077     0.029683     0.026729     0.025572     0.025055     0.024248     0.025350     0.025586     0.027405     0.027335     0.026497     0.026647     0.024791     0.024782     0.034732     0.037598     0.038341     0.038620     0.037191     0.038434     0.033977     0.033470     0.056566     0.059194     0.064131     0.064204     0.061280     0.059397     0.056812     0.054798     0.111523     0.124888     0.107612     0.105546     0.290932     0.265356     0.254347     0.245310     0.133007     0.168515 
  551.977     0.021689     0.021560     0.021722     0.021390     0.021696     0.021164     0.021508     0.014952     0.016722     0.017397     0.016203     0.014749     0.014196     0.013943     0.013552     0.014042     0.014180     0.015028     0.014972     0.014531     0.014636     0.013719     0.013762     0.018504     0.019984     0.020170     0.020261     0.019502     0.020103     0.018068     0.017911     0.028645     0.030044     0.032014     0.031895     0.030316     0.029438     0.028449     0.027753     0.053654     0.058656     0.050607     0.050413     0.140993     0.127039     0.122752     0.117626     0.058002     0.072645 
  555.012     0.012209     0.012153     0.012255     0.012064     0.012231     0.011965     0.012131     0.008720     0.009662     0.009982     0.009358     0.008600     0.008315     0.008180     0.008015     0.008218     0.008310     0.008716     0.008663     0.008450     0.008507     0.008031     0.008072     0.010499     0.011286     0.011300     0.011302     0.010904     0.011223     0.010224     0.010180     0.015510     0.016276     0.017080     0.016899     0.016092     0.015660     0.015278     0.015007     0.027402     0.029102     0.025440     0.025558     0.067512     0.060198     0.057897     0.055941     0.026381     0.031794 
  557.989     0.007426     0.007393     0.007450     0.007344     0.007434     0.007284     0.007388     0.005457     0.005984     0.006170     0.005802     0.005377     0.005218     0.005133     0.005059     0.005156     0.005200     0.005417     0.005383     0.005270     0.005301     0.005044     0.005068     0.006438     0.006870     0.006855     0.006828     0.006616     0.006802     0.006256     0.006240     0.009169     0.009590     0.009961     0.009801     0.009362     0.009131     0.008976     0.008843     0.015361     0.015928     0.014080     0.014263     0.034420     0.030414     0.029242     0.028658     0.013273     0.015422 
  561.023     0.004733     0.004706     0.004740     0.004681     0.004734     0.004649     0.004705     0.003549     0.003872     0.003975     0.003762     0.003503     0.003405     0.003356     0.003314     0.003367     0.003381     0.003508     0.003491     0.003427     0.003452     0.003297     0.003312     0.004135     0.004357     0.004344     0.004318     0.004208     0.004321     0.004009     0.004006     0.005709     0.005925     0.006108     0.005998     0.005739     0.005626     0.005562     0.005505     0.009088     0.009267     0.008276     0.008476     0.018699     0.016491     0.015899     0.015763     0.007165     0.008075 
  563.999     0.003150     0.003132     0.003150     0.003112     0.003140     0.003092     0.003127     0.002404     0.002600     0.002664     0.002531     0.002368     0.002308     0.002275     0.002248     0.002276     0.002285     0.002358     0.002347     0.002310     0.002328     0.002230     0.002242     0.002759     0.002888     0.002876     0.002849     0.002788     0.002865     0.002676     0.002678     0.003723     0.003837     0.003925     0.003853     0.003697     0.003643     0.003613     0.003601     0.005691     0.005719     0.005162     0.005337     0.010903     0.009614     0.009257     0.009295     0.004173     0.004565 
  567.032     0.002139     0.002127     0.002135     0.002116     0.002131     0.002099     0.002124     0.001651     0.001779     0.001817     0.001736     0.001629     0.001591     0.001570     0.001548     0.001566     0.001567     0.001608     0.001604     0.001584     0.001597     0.001535     0.001549     0.001881     0.001952     0.001940     0.001919     0.001892     0.001941     0.001821     0.001828     0.002486     0.002549     0.002592     0.002544     0.002453     0.002427     0.002413     0.002414     0.003669     0.003650     0.003334     0.003469     0.006610     0.005858     0.005646     0.005723     0.002551     0.002729 
  570.007     0.001484     0.001477     0.001484     0.001467     0.001479     0.001459     0.001473     0.001157     0.001241     0.001268     0.001210     0.001143     0.001116     0.001103     0.001090     0.001097     0.001101     0.001123     0.001121     0.001108     0.001120     0.001077     0.001091     0.001307     0.001350     0.001337     0.001319     0.001313     0.001342     0.001266     0.001275     0.001707     0.001738     0.001755     0.001720     0.001670     0.001653     0.001650     0.001658     0.002442     0.002403     0.002232     0.002331     0.004201     0.003739     0.003616     0.003687     0.001642     0.001722 
  573.038     0.001051     0.001046     0.001055     0.001044     0.001051     0.001037     0.001042     0.000826     0.000886     0.000904     0.000863     0.000817     0.000801     0.000792     0.000781     0.000789     0.000792     0.000803     0.000802     0.000792     0.000801     0.000771     0.000783     0.000928     0.000953     0.000942     0.000933     0.000932     0.000952     0.000899     0.000907     0.001199     0.001212     0.001216     0.001190     0.001166     0.001158     0.001159     0.001167     0.001668     0.001631     0.001535     0.001605     0.002749     0.002468     0.002374     0.002444     0.001107     0.001137 
  576.013     0.000764     0.000761     0.000764     0.000752     0.000761     0.000752     0.000756     0.000608     0.000647     0.000661     0.000631     0.000599     0.000587     0.000580     0.000574     0.000578     0.000580     0.000588     0.000584     0.000582     0.000587     0.000567     0.000573     0.000676     0.000690     0.000680     0.000673     0.000676     0.000689     0.000654     0.000658     0.000860     0.000862     0.000865     0.000843     0.000834     0.000829     0.000829     0.000836     0.001164     0.001128     0.001071     0.001123     0.001840     0.001665     0.001598     0.001652     0.000781     0.000786 
  579.043     0.000566     0.000567     0.000565     0.000559     0.000560     0.000556     0.000559     0.000456     0.000480     0.000491     0.000473     0.000449     0.000443     0.000438     0.000435     0.000431     0.000433     0.000438     0.000438     0.000437     0.000438     0.000423     0.000432     0.000501     0.000510     0.000501     0.000496     0.000502     0.000507     0.000480     0.000486     0.000627     0.000622     0.000625     0.000607     0.000604     0.000601     0.000603     0.000605     0.000817     0.000791     0.000759     0.000799     0.001251     0.001147     0.001095     0.001140     0.000570     0.000565 
  582.017     0.000427     0.000422     0.000425     0.000420     0.000422     0.000416     0.000422     0.000348     0.000368     0.000373     0.000356     0.000341     0.000337     0.000335     0.000335     0.000329     0.000332     0.000334     0.000329     0.000332     0.000331     0.000323     0.000330     0.000378     0.000384     0.000374     0.000369     0.000378     0.000379     0.000366     0.000363     0.000465     0.000458     0.000456     0.000444     0.000442     0.000442     0.000444     0.000447     0.000586     0.000564     0.000540     0.000577     0.000865     0.000804     0.000761     0.000795     0.000428     0.000417 
  585.046     0.000331     0.000325     0.000328     0.000322     0.000327     0.000325     0.000326     0.000275     0.000289     0.000290     0.000278     0.000272     0.000268     0.000264     0.000264     0.000256     0.000259     0.000263     0.000262     0.000260     0.000261     0.000251     0.000256     0.000292     0.000296     0.000290     0.000283     0.000292     0.000287     0.000277     0.000280     0.000349     0.000346     0.000342     0.000333     0.000332     0.000333     0.000332     0.000336     0.000433     0.000412     0.000397     0.000426     0.000610     0.000583     0.000541     0.000569     0.000333     0.000321 
  588.019     0.000260     0.000258     0.000255     0.000256     0.000260     0.000259     0.000256     0.000227     0.000230     0.000233     0.000226     0.000211     0.000215     0.000211     0.000212     0.000211     0.000208     0.000207     0.000210     0.000207     0.000209     0.000206     0.000209     0.000232     0.000233     0.000226     0.000223     0.000228     0.000226     0.000220     0.000224     0.000270     0.000267     0.000263     0.000255     0.000251     0.000250     0.000255     0.000260     0.000325     0.000302     0.000301     0.000318     0.000448     0.000437     0.000395     0.000422     0.000267     0.000256 
  591.047     0.000212     0.000211     0.000211     0.000207     0.000209     0.000209     0.000208     0.000182     0.000189     0.000191     0.000185     0.000180     0.000180     0.000174     0.000174     0.000173     0.000178     0.000172     0.000171     0.000167     0.000172     0.000167     0.000175     0.000188     0.000189     0.000181     0.000178     0.000185     0.000183     0.000179     0.000179     0.000215     0.000209     0.000203     0.000198     0.000201     0.000198     0.000199     0.000206     0.000252     0.000236     0.000231     0.000245     0.000318     0.000304     0.000260     0.000290     0.000220     0.000206 
  594.019     0.000177     0.000176     0.000177     0.000175     0.000175     0.000175     0.000176     0.000157     0.000159     0.000162     0.000159     0.000153     0.000152     0.000151     0.000150     0.000148     0.000148     0.000148     0.000143     0.000145     0.000147     0.000143     0.000148     0.000157     0.000155     0.000154     0.000148     0.000158     0.000153     0.000149     0.000149     0.000175     0.000174     0.000169     0.000164     0.000164     0.000163     0.000166     0.000168     0.000193     0.000177     0.000170     0.000186     0.000171     0.000150     0.000109     0.000143     0.000186     0.000173 
  597.046     0.000147     0.000145     0.000148     0.000145     0.000146     0.000144     0.000146     0.000131     0.000133     0.000135     0.000130     0.000127     0.000131     0.000130     0.000128     0.000127     0.000125     0.000124     0.000123     0.000121     0.000121     0.000121     0.000123     0.000128     0.000132     0.000127     0.000121     0.000127     0.000123     0.000119     0.000121     0.000136     0.000131     0.000129     0.000122     0.000120     0.000118     0.000122     0.000126     0.000117     0.000098     0.000087     0.000109     0.000066     0.000052     0.000040     0.000055     0.000159     0.000143 
  600.073     0.000102     0.000099     0.000102     0.000101     0.000101     0.000098     0.000101     0.000092     0.000095     0.000094     0.000091     0.000091     0.000090     0.000091     0.000082     0.000088     0.000089     0.000089     0.000082     0.000083     0.000082     0.000080     0.000085     0.000089     0.000092     0.000082     0.000079     0.000079     0.000076     0.000075     0.000079     0.000080     0.000074     0.000075     0.000065     0.000061     0.000062     0.000066     0.000071     0.000051     0.000041     0.000036     0.000048     0.000025     0.000022     0.000016     0.000023     0.000140     0.000123 
  603.043     0.000052     0.000048     0.000051     0.000051     0.000052     0.000049     0.000052     0.000048     0.000049     0.000047     0.000049     0.000048     0.000045     0.000045     0.000047     0.000047     0.000045     0.000046     0.000043     0.000040     0.000039     0.000043     0.000046     0.000045     0.000046     0.000040     0.000034     0.000036     0.000035     0.000036     0.000039     0.000034     0.000032     0.000033     0.000031     0.000026     0.000028     0.000030     0.000034     0.000025     0.000018     0.000016     0.000021     0.000005     0.000005     0.000001     0.000010     0.000126     0.000112 
  606.068     0.000027     0.000023     0.000026     0.000023     0.000025     0.000023     0.000026     0.000019     0.000023     0.000025     0.000023     0.000022     0.000024     0.000022     0.000024     0.000023     0.000024     0.000023     0.000020     0.000020     0.000020     0.000022     0.000022     0.000021     0.000022     0.000018     0.000018     0.000018     0.000016     0.000016     0.000022     0.000015     0.000015     0.000014     0.000012     0.000014     0.000012     0.000012     0.000017     0.000002     0.000001    -0.000000     0.000006     0.000001     0.000000     0.000001     0.000001     0.000116     0.000098 
  609.038     0.000011     0.000011     0.000010     0.000013     0.000012     0.000011     0.000011     0.000010     0.000010     0.000010     0.000010     0.000011     0.000011     0.000011     0.000001     0.000010     0.000007     0.000010     0.000010     0.000008     0.000009     0.000010     0.000011     0.000010     0.000002     0.000001     0.000001     0.000001     0.000000     0.000005     0.000008     0.000004    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000107     0.000094 
  612.062     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000004     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000002     0.000002     0.000000     0.000001     0.000000    -0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000102     0.000087 
  615.086     0.000002     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000101     0.000083 
  618.053     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000100     0.000080 
  621.076     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000096     0.000077 
  624.099     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000095     0.000072 
  627.064     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000101     0.000077 
  630.086     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000100     0.000076 
  633.106     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000105     0.000076 
  636.071     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000002     0.000113     0.000080 
  639.090     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000122     0.000085 
  642.109     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000128     0.000090 
  645.128     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000002     0.000136     0.000097 
  648.090     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000146     0.000106 
  651.107     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000136     0.000107 
  654.123     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000099     0.000088 
  657.139     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000072     0.000059 
  660.099     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000059     0.000042 
  663.114     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000043     0.000037 
  666.129     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000000     0.000002     0.000001     0.000001     0.000000     0.000001     0.000033     0.000026 
  669.142     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000002     0.000000     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000006     0.000002     0.000002     0.000002     0.000001     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000020     0.000014 
  672.155     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000002    -0.000000     0.000002     0.000001     0.000001     0.000001     0.000000     0.000002     0.000002     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000013     0.000012 
  675.168     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000011     0.000005 
  678.124     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000002     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000001    -0.000000     0.000001     0.000013     0.000007 
  681.136     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000014     0.000007 
  684.146     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000016     0.000011 
  687.157     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001     0.000017     0.000008 
  690.166     0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000002     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000001    -0.000000     0.000001     0.000014     0.000013 
  693.175     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000001     0.000000     0.000001     0.000018     0.000014 
  696.183     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000017     0.000012 
  699.191     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000029     0.000018 
  702.198     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000001     0.000052     0.000030 
  705.205     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000097     0.000057 
  708.211     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000136     0.000100 
  711.216     0.000001     0.000001     0.000000     0.000000    -0.000000    -0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000118     0.000114 
  714.220     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000084     0.000092 
  717.224     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000059     0.000061 
  720.228     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000001    -0.000000    -0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000044     0.000046 
  723.230     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000001    -0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000001    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000043     0.000038 
  726.232     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000002     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000049     0.000034 
  729.234     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000001    -0.000001    -0.000002     0.000000     0.000000    -0.000001    -0.000001     0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000054     0.000041 
  732.234     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000002     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000001     0.000056     0.000046 
  735.235     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000002    -0.000000    -0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000059     0.000052 
  738.234     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000002    -0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000065     0.000054 
  741.233     0.000002     0.000001     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000000    -0.000002    -0.000000     0.000001     0.000000     0.000059     0.000047 
  744.231     0.000001    -0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000001     0.000000    -0.000001     0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000001     0.000000    -0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000002     0.000054     0.000042 
  747.228     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000058     0.000046 
  750.225     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000001    -0.000001    -0.000001     0.000000     0.000000     0.000001     0.000066     0.000047 
  753.221     0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000002    -0.000000     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000002    -0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000002     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000064     0.000061 
  756.272     0.000002     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000002    -0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000002    -0.000001     0.000001    -0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000087     0.000068 
  759.267     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000002    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000011     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000002     0.000001     0.000088     0.000080 
  762.261     0.000001     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000    -0.000001    -0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000012     0.000020     0.000003     0.000022     0.000083     0.000079 
  765.254     0.000002     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000003     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000    -0.000001    -0.000000     0.000001     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000010     0.000022     0.000020     0.000013     0.000018     0.000002     0.000021     0.000079     0.000070 
  768.247     0.000030     0.000030     0.000026     0.000025     0.000029     0.000028     0.000032     0.000028     0.000022     0.000029     0.000028     0.000027     0.000031     0.000027     0.000034     0.000021     0.000021     0.000025     0.000024     0.000028     0.000025     0.000026     0.000031     0.000022     0.000013     0.000020     0.000023     0.000021     0.000029     0.000023     0.000023     0.000024     0.000025     0.000022     0.000023     0.000021     0.000021     0.000025     0.000025     0.000027     0.000024     0.000024     0.000028     0.000001    -0.000000     0.000004     0.000001     0.000079     0.000070 
  771.294     0.000042     0.000044     0.000036     0.000035     0.000041     0.000038     0.000045     0.000033     0.000043     0.000036     0.000040     0.000037     0.000034     0.000037     0.000039     0.000032     0.000034     0.000038     0.000033     0.000032     0.000037     0.000035     0.000037     0.000032     0.000036     0.000027     0.000028     0.000025     0.000033     0.000031     0.000033     0.000020     0.000029     0.000024     0.000026     0.000024     0.000027     0.000028     0.000023     0.000014     0.000010    -0.000001     0.000013     0.000003     0.000002     0.000001     0.000004     0.000087     0.000073 
  774.286     0.000034     0.000034     0.000032     0.000036     0.000037     0.000032     0.000037     0.000033     0.000033     0.000034     0.000028     0.000028     0.000030     0.000026     0.000030     0.000036     0.000032     0.000030     0.000026     0.000023     0.000026     0.000031     0.000034     0.000025     0.000030     0.000022     0.000027     0.000015     0.000022     0.000024     0.000028     0.000012     0.000023     0.000020     0.000003     0.000009     0.000010     0.000009     0.000020     0.000000     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001     0.000092     0.000076 
  777.277     0.000018     0.000022     0.000011     0.000013     0.000018     0.000019     0.000010     0.000002     0.000012     0.000011     0.000003     0.000011     0.000011     0.000011     0.000010     0.000011     0.000004     0.000002     0.000013     0.000002     0.000003     0.000013     0.000011     0.000001     0.000010     0.000001     0.000002     0.000001     0.000011    -0.000000     0.000001     0.000001     0.000003    -0.000000     0.000003     0.000003     0.000002    -0.000001     0.000001     0.000002     0.000001     0.000001     0.000004    -0.000001     0.000001     0.000001     0.000001     0.000099     0.000079 
  780.266     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000000     0.000002     0.000004     0.000007     0.000000     0.000001     0.000003     0.000002    -0.000000     0.000003     0.000004     0.000002     0.000004     0.000002     0.000002     0.000002     0.000000     0.000003     0.000002     0.000003     0.000002     0.000003     0.000001     0.000001     0.000003     0.000002     0.000003     0.000002     0.000001     0.000002     0.000002     0.000003     0.000003     0.000000     0.000001     0.000002     0.000001     0.000001     0.000002     0.000003     0.000020     0.000107     0.000094 
  783.311     0.000003     0.000003     0.000000     0.000001     0.000003     0.000002     0.000003     0.000003     0.000003     0.000003     0.000002     0.000003     0.000003     0.000002     0.000001     0.000003     0.000005     0.000002     0.000011     0.000001     0.000001     0.000001     0.000003     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000003     0.000003     0.000002     0.000005     0.000024     0.000099     0.000094 
  786.300     0.000004     0.000004     0.000012     0.000020     0.000004     0.000012     0.000003     0.000004     0.000013     0.000012     0.000013     0.000004     0.000004     0.000002     0.000003     0.000003     0.000002     0.000002     0.000003     0.000002     0.000001     0.000002     0.000003     0.000001     0.000002     0.000002     0.000002     0.000003     0.000013     0.000001     0.000003     0.000011     0.000002     0.000001     0.000003     0.000002     0.000012     0.000003     0.000002     0.000030     0.000023     0.000028     0.000027     0.000004     0.000004    -0.000000     0.000001     0.000075     0.000084 
  789.288     0.000050     0.000051     0.000050     0.000050     0.000050     0.000053     0.000050     0.000038     0.000046     0.000049     0.000047     0.000047     0.000053     0.000046     0.000048     0.000045     0.000037     0.000042     0.000036     0.000046     0.000036     0.000046     0.000045     0.000036     0.000035     0.000033     0.000036     0.000037     0.000044     0.000044     0.000039     0.000039     0.000039     0.000031     0.000035     0.000035     0.000036     0.000041     0.000037     0.000017     0.000021     0.000023     0.000033     0.000002     0.000002     0.000003     0.000004     0.000056     0.000060 
  792.275     0.000070     0.000065     0.000067     0.000064     0.000072     0.000067     0.000061     0.000064     0.000061     0.000063     0.000058     0.000062     0.000064     0.000055     0.000056     0.000060     0.000057     0.000050     0.000051     0.000051     0.000052     0.000062     0.000059     0.000043     0.000046     0.000037     0.000035     0.000043     0.000044     0.000048     0.000050     0.000034     0.000029     0.000028     0.000026     0.000024     0.000026     0.000027     0.000038    -0.000000     0.000000     0.000002     0.000013     0.000001     0.000000     0.000003     0.000003     0.000045     0.000038 
  795.316     0.000046     0.000042     0.000047     0.000048     0.000047     0.000051     0.000049     0.000048     0.000047     0.000048     0.000036     0.000047     0.000042     0.000046     0.000041     0.000040     0.000037     0.000039     0.000039     0.000034     0.000037     0.000041     0.000038     0.000029     0.000029     0.000031     0.000023     0.000024     0.000030     0.000028     0.000033     0.000029     0.000002     0.000013     0.000012     0.000002     0.000025     0.000027     0.000028     0.000002     0.000003     0.000005     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000036     0.000036 
  798.302     0.000033     0.000034     0.000029     0.000036     0.000042     0.000033     0.000030     0.000033     0.000033     0.000030     0.000029     0.000030     0.000027     0.000033     0.000029     0.000027     0.000032     0.000029     0.000031     0.000024     0.000026     0.000030     0.000029     0.000023     0.000001     0.000012     0.000010     0.000013     0.000003     0.000012     0.000023     0.000012     0.000007     0.000002     0.000003     0.000004     0.000001     0.000002     0.000001     0.000001     0.000001     0.000003     0.000003     0.000001     0.000000     0.000000     0.000001     0.000031     0.000026 
  801.287     0.000002     0.000001     0.000002     0.000002     0.000003    -0.000001     0.000002     0.000002     0.000002     0.000001     0.000001     0.000003     0.000000     0.000002    -0.000000     0.000002     0.000002     0.000000     0.000002     0.000001    -0.000001     0.000001     0.000002     0.000000    -0.000003     0.000002    -0.000001     0.000001     0.000002    -0.000001    -0.000001     0.000001     0.000004     0.000002     0.000003     0.000002     0.000002     0.000003     0.000003    -0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000000     0.000032     0.000027 
  804.327     0.000001     0.000004     0.000002     0.000003     0.000002     0.000002     0.000002     0.000001     0.000002     0.000003     0.000002     0.000003     0.000002     0.000002     0.000003     0.000003     0.000004     0.000001     0.000002     0.000002     0.000000     0.000000     0.000003     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001    -0.000000    -0.000000     0.000002    -0.000000     0.000000     0.000002     0.000001     0.000000     0.000036     0.000026 
  807.310     0.000001     0.000003     0.000002     0.000000     0.000001     0.000001     0.000001     0.000000     0.000002     0.000002    -0.000000     0.000002     0.000000    -0.000000     0.000000     0.000000     0.000002     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000002    -0.000001     0.000000     0.000002    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000002    -0.000002    -0.000000     0.000000    -0.000001     0.000001     0.000001     0.000000     0.000037     0.000029 
  810.348     0.000001     0.000001     0.000000    -0.000000    -0.000001     0.000001     0.000000     0.000000     0.000001     0.000002     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000002     0.000001    -0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000002    -0.000000     0.000000    -0.000001    -0.000001     0.000002     0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000040     0.000028 
  813.331     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000040     0.000027 
  816.312     0.000001     0.000001     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000002     0.000000     0.000000    -0.000001    -0.000002    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000002    -0.000002    -0.000003    -0.000000    -0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000054     0.000032 
  819.348     0.000001     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000002    -0.000001     0.000001    -0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000000    -0.000001     0.000001     0.000002     0.000001    -0.000000     0.000002     0.000000     0.000000     0.000001     0.000001    -0.000002    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000002    -0.000001     0.000066     0.000043 
  822.328     0.000001     0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000001    -0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000001     0.000002     0.000001     0.000001     0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000082     0.000057 
  825.362     0.000001     0.000002     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000002     0.000001     0.000001    -0.000001     0.000001     0.000002    -0.000001     0.000001     0.000001     0.000000     0.000001    -0.000002     0.000001     0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000001    -0.000001    -0.000000    -0.000001     0.000002     0.000001     0.000000    -0.000000     0.000001    -0.000001    -0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000000     0.000001     0.000106     0.000076 
  828.341     0.000001     0.000002     0.000000     0.000000    -0.000000     0.000003     0.000001     0.000000     0.000001     0.000002     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000002     0.000001     0.000000    -0.000002    -0.000000    -0.000000    -0.000001     0.000001     0.000000    -0.000001     0.000001    -0.000001     0.000001    -0.000002     0.000001     0.000000     0.000001    -0.000001     0.000001    -0.000002    -0.000001     0.000000     0.000001    -0.000001     0.000001     0.000002     0.000001     0.000157     0.000112 
  831.374     0.000001     0.000002     0.000000    -0.000000     0.000000     0.000000     0.000002     0.000002     0.000001     0.000003     0.000001     0.000002    -0.000001     0.000002     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000000    -0.000002    -0.000000     0.000001    -0.000002     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000002    -0.000001     0.000000     0.000000     0.000002    -0.000000     0.000001     0.000000    -0.000001    -0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000222     0.000141 
  834.351     0.000003     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000002     0.000002     0.000000     0.000002     0.000001     0.000003     0.000001     0.000001     0.000003    -0.000000     0.000002     0.000002    -0.000000     0.000001    -0.000001     0.000002     0.000002    -0.000001     0.000001     0.000002    -0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002    -0.000001     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000002     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000255     0.000186 
  837.382     0.000002     0.000001     0.000000     0.000002     0.000001     0.000002     0.000000     0.000002     0.000001     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000002    -0.000000     0.000001     0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000003     0.000002     0.000000    -0.000000     0.000002    -0.000001    -0.000001     0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000260     0.000228 
  840.357     0.000002     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000002    -0.000000     0.000001     0.000000     0.000000     0.000002     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000001     0.000003    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000002     0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000002     0.000235     0.000233 
  843.387     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000002     0.000000    -0.000000    -0.000000     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000002     0.000216     0.000205 
  846.361     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000002    -0.000000     0.000003     0.000001     0.000001     0.000001    -0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001    -0.000000     0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000002     0.000000     0.000001    -0.000002     0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000002     0.000002     0.000168     0.000166 
  849.389     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000001    -0.000001     0.000001    -0.000000     0.000002     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000001     0.000001     0.000001     0.000002    -0.000001     0.000000     0.000001     0.000000    -0.000002     0.000001     0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000000     0.000003    -0.000001     0.000003     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000001    -0.000001     0.000000     0.000039     0.000002     0.000127     0.000126 
  852.362     0.000002     0.000000     0.000002     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000002    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000002     0.000001     0.000001     0.000002     0.000000     0.000000     0.000001     0.000001    -0.000002     0.000002     0.000000     0.000002     0.000000    -0.000000     0.000002    -0.000000     0.000001     0.000000     0.000002     0.000002    -0.000001    -0.000000     0.000002     0.000000     0.000000     0.000002    -0.000000     0.000001     0.000001     0.000085     0.000003     0.000098     0.000104 
  855.389     0.000002     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000000    -0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000001     0.000002     0.000000     0.000002     0.000002     0.000000     0.000001     0.000002     0.000000    -0.000002     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000001     0.000003     0.000001     0.000002     0.000001     0.000116     0.000001     0.000082     0.000080 
  858.359     0.000001     0.000002     0.000001    -0.000001     0.000002     0.000001     0.000000     0.000001    -0.000000     0.000002     0.000000     0.000002     0.000001     0.000001     0.000002     0.000000     0.000002    -0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000000     0.000002     0.000000     0.000003     0.000001     0.000000     0.000001     0.000002     0.000003    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000003    -0.000001     0.000000     0.000002     0.000002     0.000001     0.000128     0.000002     0.000071     0.000067 
  861.385     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000002     0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000002     0.000001    -0.000000     0.000002     0.000002     0.000003     0.000001     0.000002     0.000002     0.000002    -0.000000     0.000002     0.000004     0.000000     0.000001     0.000001     0.000002     0.000001     0.000128     0.000003     0.000058     0.000045 
  864.409     0.000002     0.000001     0.000000     0.000001     0.000000     0.000002     0.000001     0.000000     0.000000     0.000002    -0.000000     0.000003     0.000001     0.000001     0.000003     0.000000     0.000001    -0.000000     0.000002     0.000001    -0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000001    -0.000000     0.000002     0.000003     0.000002    -0.000000     0.000002     0.000003     0.000002    -0.000000     0.000001     0.000004    -0.000000     0.000001     0.000002     0.000001     0.000001     0.000121     0.000002     0.000057     0.000045 
  867.378     0.000001     0.000001     0.000000     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000003     0.000000     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000000     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000000     0.000002     0.000002     0.000003     0.000000     0.000003     0.000001     0.000000     0.000000     0.000002     0.000004    -0.000000     0.000002     0.000003     0.000003     0.000002     0.000113     0.000004     0.000050     0.000042 
  870.400     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000000     0.000002     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000000     0.000000     0.000002    -0.000000     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000002     0.000003     0.000002     0.000001     0.000000     0.000002     0.000004     0.000001     0.000002     0.000003     0.000003     0.000003     0.000112     0.000005     0.000047     0.000035 
  873.422     0.000003     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000003     0.000003     0.000001     0.000001     0.000001     0.000003     0.000003     0.000000     0.000003     0.000001     0.000002     0.000003     0.000000     0.000003    -0.000000     0.000001    -0.000001     0.000001     0.000000     0.000001     0.000003     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001     0.000003     0.000002     0.000002     0.000003     0.000003     0.000001     0.000119     0.000003     0.000042     0.000036 
  876.389     0.000004     0.000002     0.000002     0.000002     0.000003     0.000004     0.000004     0.000002     0.000003     0.000003     0.000002     0.000003     0.000001     0.000003     0.000003     0.000003     0.000002     0.000003     0.000004     0.000003     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000002     0.000003     0.000002     0.000002     0.000002     0.000004     0.000005     0.000002     0.000003     0.000003     0.000002     0.000001     0.000003     0.000006     0.000000     0.000003     0.000012     0.000002     0.000001     0.000127     0.000003     0.000045     0.000041 
  879.409     0.000005     0.000013     0.000003     0.000004     0.000004     0.000003     0.000004     0.000002     0.000005     0.000004     0.000003     0.000006     0.000004     0.000004     0.000005     0.000011     0.000003     0.000003     0.000004     0.000003     0.000002     0.000004     0.000004     0.000015     0.000002     0.000003     0.000003     0.000003     0.000003     0.000002     0.000004     0.000004     0.000005     0.000002     0.000004     0.000003     0.000003     0.000002     0.000005     0.000006     0.000000     0.000004     0.000002     0.000002     0.000001     0.000116     0.000003     0.000049     0.000034 
  882.428     0.000005     0.000002     0.000003     0.000004     0.000003     0.000002     0.000005     0.000003     0.000005     0.000004     0.000001     0.000005     0.000004     0.000005     0.000005     0.000003     0.000005     0.000004     0.000005     0.000005    -0.000000     0.000004     0.000005     0.000002     0.000002     0.000004     0.000004     0.000004     0.000002     0.000002     0.000004     0.000005     0.000005     0.000003     0.000004     0.000004     0.000003     0.000002     0.000004     0.000004     0.000001     0.000002     0.000003     0.000004     0.000001     0.000103     0.000002     0.000050     0.000037 
  885.447     0.000003     0.000003     0.000003     0.000003     0.000003     0.000002     0.000003    -0.000000     0.000004     0.000003     0.000003     0.000004     0.000002     0.000003     0.000005     0.000003     0.000003     0.000002     0.000004     0.000003     0.000002     0.000004     0.000002     0.000002     0.000002     0.000002     0.000004     0.000003     0.000003     0.000003     0.000003     0.000004     0.000004     0.000000     0.000004     0.000003     0.000002     0.000002     0.000003     0.000004     0.000001     0.000001     0.000003     0.000004     0.000000     0.000110     0.000003     0.000046     0.000034 
  888.410     0.000003     0.000001     0.000002     0.000001     0.000002     0.000001     0.000002     0.000002     0.000003     0.000002     0.000002     0.000003     0.000002     0.000002     0.000003     0.000002     0.000004     0.000001     0.000002     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001     0.000003     0.000003     0.000001     0.000002     0.000001     0.000001     0.000003     0.000003     0.000001     0.000002     0.000001     0.000002     0.000001     0.000003     0.000003     0.000001     0.000003     0.000003     0.000004     0.000001     0.000107     0.000003     0.000043     0.000044 
  891.427     0.000002     0.000002     0.000001    -0.000000     0.000002     0.000002     0.000001     0.000000     0.000003     0.000002    -0.000000     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000000     0.000003     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000002     0.000003     0.000002     0.000001     0.000002     0.000001     0.000003     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000000     0.000002     0.000002     0.000003     0.000001     0.000091     0.000002     0.000061     0.000049 
  894.444     0.000001    -0.000000     0.000001    -0.000001     0.000001     0.000002     0.000000     0.000001     0.000002     0.000001     0.000000     0.000002     0.000002     0.000001     0.000000     0.000003     0.000002    -0.000000     0.000003     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000000     0.000002     0.000003     0.000001     0.000000     0.000001     0.000003     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002     0.000001     0.000002     0.000004     0.000000     0.000077     0.000002     0.000056     0.000037 
  897.459     0.000002     0.000001    -0.000001    -0.000000     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000002     0.000002     0.000002     0.000002    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000016     0.000002    -0.000001     0.000001     0.000003     0.000000     0.000079     0.000005     0.000069     0.000056 
  900.419     0.000001    -0.000000    -0.000000    -0.000000     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001     0.000000     0.000002     0.000001     0.000000     0.000002     0.000001     0.000002     0.000001     0.000001    -0.000000    -0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000002     0.000001     0.000000     0.000001     0.000000     0.000001     0.000002     0.000001     0.000001     0.000003     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000003     0.000003     0.000002     0.000000     0.000108     0.000005     0.000083     0.000063 
  903.433     0.000002     0.000002     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000002     0.000002    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000000     0.000002     0.000001     0.000001     0.000002     0.000002     0.000002     0.000002     0.000013     0.000004     0.000002     0.000003     0.000003     0.000004     0.000002     0.000061     0.000003     0.000088     0.000059 
  906.446     0.000002    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000002     0.000002    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000001     0.000003     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000002     0.000003     0.000003     0.000001     0.000003     0.000002     0.000002     0.000003     0.000001     0.000117     0.000083 
  909.458     0.000002    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000002    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000000     0.000001     0.000000     0.000002     0.000001     0.000000     0.000001     0.000002     0.000001     0.000002     0.000001     0.000128     0.000080 
  912.469     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000002     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000163     0.000119 
  915.480     0.000001     0.000002     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000156     0.000103 
  918.489     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000205     0.000139 
  921.443     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000231     0.000170 
  924.451     0.000001     0.000000    -0.000000     0.000004     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000241     0.000142 
  927.458     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000341     0.000252 
  930.465     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000277     0.000219 
  933.470     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000306     0.000244 
  936.475     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000184     0.000242 
  939.478     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000001    -0.000001    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000122     0.000118 
  942.481     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000002     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000088     0.000121 
  945.483     0.000001     0.000001    -0.000000     0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000001    -0.000001     0.000001     0.000002     0.000000    -0.000000    -0.000000     0.000002     0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000002    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000001    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000039     0.000043 
  948.484     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000000    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000039     0.000039 
  951.484     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000020     0.000020 
  954.538     0.000001     0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000024     0.000018 
  957.537     0.000001     0.000001    -0.000001    -0.000001     0.000001    -0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000001    -0.000001     0.000000     0.000002    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000017     0.000019 
  960.534     0.000001     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000018     0.000007 
  963.531     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000014     0.000016 
  966.526     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000017     0.000002 
  969.521     0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000016     0.000014 
  972.515     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000016     0.000001 
  975.563    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000022     0.000019 
  978.555     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000026     0.000007 
  981.546     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000032     0.000025 
  984.537     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000033     0.000014 
  987.580     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000036     0.000037 
  990.569     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000045     0.000022 
  993.556     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000035     0.000046 
  996.543     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000035     0.000017 
  999.583     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000025     0.000034 
 1002.568     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000002     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000029     0.000007 
 1005.552     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000020     0.000023 
 1008.589     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002    -0.000000     0.000001     0.000000     0.000001     0.000002     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000002     0.000001     0.000022     0.000003 
 1011.571     0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000018     0.000016 
 1014.606     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000002     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000025     0.000001 
 1017.587     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000020     0.000001 
 1020.620     0.000001     0.000001     0.000000     0.000000     0.000010     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000002     0.000001     0.000000     0.000001     0.000024    -0.000001 
 1023.598     0.000001     0.000002     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000002     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000023     0.000002 
 1026.629     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000002    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000002     0.000000     0.000002     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000002     0.000002     0.000026     0.000003 
 1029.606     0.000001     0.000002     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000002    -0.000000     0.000001     0.000002     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000002     0.000028     0.000002 
 1032.635     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000003    -0.000000     0.000000     0.000001     0.000002     0.000002     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000001     0.000002    -0.000000     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000     0.000002     0.000000     0.000001     0.000002     0.000001     0.000001     0.000000     0.000001     0.000002     0.000029     0.000002 
 1035.610     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001     0.000000     0.000001     0.000002     0.000002     0.000001     0.000002     0.000000     0.000002     0.000000     0.000000     0.000001     0.000000     0.000001     0.000002     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000002     0.000001     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000032     0.000001 
 1038.637     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002    -0.000000     0.000000     0.000002     0.000000    -0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000002     0.000000     0.000001     0.000003     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000002     0.000001     0.000002     0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000032     0.000002 
 1041.610     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000002    -0.000001     0.000000    -0.000001     0.000002     0.000002     0.000000     0.000002     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001    -0.000001     0.000002    -0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000002     0.000036     0.000002 
 1044.635     0.000001     0.000002     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000000     0.000003    -0.000000    -0.000000     0.000000     0.000002     0.000003     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000003     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000003     0.000001    -0.000001     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000001     0.000002     0.000001     0.000001     0.000043     0.000002 
 1047.660     0.000002     0.000001     0.000001     0.000003     0.000001     0.000002     0.000002    -0.000000     0.000000     0.000003    -0.000000     0.000001     0.000000     0.000004     0.000003     0.000001     0.000002    -0.000000    -0.000000     0.000001    -0.000001     0.000002    -0.000000     0.000001     0.000002     0.000000     0.000000     0.000002     0.000001     0.000001     0.000002     0.000000     0.000002     0.000000     0.000002     0.000002    -0.000000    -0.000000     0.000001     0.000000     0.000001     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000047     0.000003 
 1050.629     0.000002     0.000002     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000002     0.000002     0.000001     0.000002    -0.000000     0.000001     0.000002     0.000000     0.000002     0.000000     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000     0.000002     0.000000     0.000000     0.000002     0.000001     0.000001     0.000000     0.000001     0.000002     0.000041     0.000003 
 1053.652     0.000001     0.000002     0.000001     0.000002     0.000012     0.000003     0.000002     0.000002     0.000000     0.000002    -0.000000    -0.000001    -0.000000     0.000004     0.000003     0.000000     0.000001     0.000001     0.000001     0.000002     0.000000     0.000002     0.000000     0.000000     0.000000     0.000001    -0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000002    -0.000000    -0.000000     0.000002     0.000003     0.000058     0.000005 
 1056.620     0.000001     0.000003     0.000002     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000003     0.000000     0.000001    -0.000000     0.000005     0.000003     0.000001     0.000003     0.000002     0.000002     0.000002     0.000001     0.000002    -0.000000     0.000002     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000002     0.000002     0.000001     0.000003     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000002    -0.000000     0.000002     0.000001     0.000003     0.000064     0.000004 
 1059.640     0.000002     0.000003     0.000002     0.000001     0.000002     0.000001     0.000002     0.000001     0.000003     0.000004     0.000001     0.000001     0.000001     0.000003     0.000003     0.000002     0.000003     0.000002     0.000003     0.000003    -0.000001     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000001     0.000002     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001    -0.000001     0.000002     0.000002     0.000004     0.000063     0.000005 
 1062.660     0.000002     0.000002     0.000002     0.000003     0.000001     0.000004     0.000002     0.000003     0.000001     0.000004     0.000002     0.000003     0.000001     0.000005     0.000004     0.000002     0.000004     0.000002     0.000002     0.000003    -0.000002     0.000002     0.000001     0.000002     0.000001     0.000000     0.000002     0.000003     0.000003     0.000001     0.000003     0.000001    -0.000001     0.000001     0.000002     0.000002    -0.000000     0.000003     0.000003    -0.000000     0.000000     0.000003     0.000001    -0.000001     0.000001     0.000002     0.000003     0.000068     0.000007 
 1065.678     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000003     0.000004     0.000002     0.000003     0.000003     0.000005     0.000003     0.000002     0.000003     0.000001     0.000003     0.000002     0.000001     0.000004     0.000001     0.000003     0.000002     0.000002     0.000002     0.000004     0.000002     0.000003    -0.000000     0.000003     0.000002     0.000001     0.000003     0.000000     0.000000     0.000002     0.000001     0.000001     0.000001     0.000004     0.000003    -0.000000     0.000001     0.000003     0.000005     0.000093     0.000033 
 1068.642     0.000003     0.000002     0.000004     0.000002     0.000004     0.000005     0.000004     0.000003     0.000002     0.000005     0.000004     0.000003     0.000001     0.000005     0.000002     0.000002     0.000004     0.000001     0.000004     0.000003     0.000001     0.000003     0.000002     0.000002     0.000001     0.000003     0.000003     0.000004     0.000003     0.000003     0.000003     0.000002     0.000004     0.000002     0.000002     0.000002     0.000001     0.000003     0.000001     0.000001     0.000002     0.000003     0.000003     0.000001     0.000003     0.000003     0.000003     0.000095     0.000048 
 1071.658     0.000004     0.000007     0.000006     0.000004     0.000004     0.000006     0.000003     0.000006     0.000004     0.000005     0.000004     0.000005     0.000003     0.000006     0.000005     0.000003     0.000003     0.000002     0.000004     0.000004     0.000002     0.000003     0.000003     0.000004     0.000001     0.000004     0.000003     0.000004     0.000002     0.000002     0.000003     0.000004     0.000003     0.000002     0.000004     0.000003     0.000003     0.000002     0.000004     0.000002     0.000002     0.000004     0.000004     0.000004     0.000002     0.000002     0.000003     0.000097     0.000042 
 1074.674     0.000006     0.000007     0.000007     0.000006     0.000005     0.000007     0.000004     0.000006     0.000002     0.000006     0.000004     0.000007     0.000004     0.000006     0.000005     0.000002     0.000003     0.000004     0.000004     0.000006     0.000001     0.000003     0.000006     0.000003     0.000004     0.000003     0.000004     0.000005     0.000004     0.000003     0.000003     0.000004     0.000003     0.000003     0.000004     0.000002     0.000002     0.000003     0.000002     0.000002     0.000002     0.000005     0.000007     0.000004     0.000003     0.000003     0.000008     0.000097     0.000050 
 1077.688     0.000005     0.000006     0.000007     0.000003     0.000003     0.000007     0.000004     0.000005     0.000005     0.000007     0.000003     0.000004     0.000005     0.000005     0.000005     0.000002     0.000006     0.000005     0.000007     0.000005     0.000002     0.000006     0.000003     0.000004     0.000005     0.000002     0.000004     0.000006     0.000003     0.000005     0.000006     0.000004     0.000002     0.000001     0.000003     0.000003     0.000003     0.000003     0.000006     0.000003     0.000004     0.000002     0.000006     0.000005     0.000001     0.000004     0.000009     0.000101     0.000048 
 1080.702     0.000006     0.000007     0.000007     0.000008     0.000002     0.000006     0.000005     0.000006     0.000005     0.000007     0.000002     0.000004     0.000003     0.000007     0.000006     0.000005     0.000005     0.000006     0.000006     0.000005     0.000006     0.000007     0.000004     0.000006     0.000004     0.000006     0.000005     0.000007     0.000004     0.000005     0.000005     0.000005     0.000004     0.000002     0.000006     0.000002     0.000003     0.000004     0.000006     0.000004     0.000002     0.000005     0.000004     0.000004     0.000001     0.000004     0.000007     0.000119     0.000056 
 1083.660     0.000009     0.000006     0.000009     0.000006     0.000005     0.000008     0.000006     0.000009     0.000009     0.000010     0.000005     0.000006     0.000005     0.000008     0.000004     0.000005     0.000009     0.000006     0.000008     0.000005     0.000007     0.000006     0.000006     0.000005     0.000007     0.000005     0.000006     0.000007     0.000006     0.000004     0.000005     0.000005     0.000004     0.000006     0.000004     0.000004     0.000004     0.000003     0.000005     0.000003     0.000007     0.000005     0.000005     0.000005     0.000002     0.000005     0.000004     0.000106     0.000065 
 1086.672     0.000006     0.000007     0.000008     0.000007     0.000005     0.000006     0.000008     0.000007     0.000006     0.000010     0.000007     0.000006     0.000004     0.000010     0.000005     0.000004     0.000007     0.000004     0.000009     0.000007     0.000005     0.000006     0.000005     0.000003     0.000006     0.000006     0.000005     0.000005     0.000004     0.000002     0.000005     0.000006     0.000006     0.000005     0.000006     0.000003     0.000006     0.000004     0.000004     0.000005     0.000005     0.000007     0.000005     0.000006     0.000007     0.000004     0.000009     0.000116     0.000034 
 1089.682     0.000007     0.000007     0.000008     0.000008     0.000008     0.000006     0.000006     0.000007     0.000007     0.000010     0.000010     0.000006     0.000005     0.000009     0.000005     0.000005     0.000010     0.000008     0.000010     0.000007     0.000007     0.000006     0.000003     0.000004     0.000010     0.000006     0.000006     0.000007     0.000008     0.000002     0.000004     0.000009     0.000007     0.000004     0.000008     0.000006     0.000003     0.000003     0.000007     0.000004     0.000007     0.000006     0.000009     0.000005     0.000006     0.000007     0.000010     0.000130     0.000068 
 1092.691     0.000009     0.000008     0.000007     0.000007     0.000010     0.000010     0.000005     0.000007     0.000010     0.000011     0.000005     0.000013     0.000006     0.000008     0.000008     0.000005     0.000007     0.000006     0.000009     0.000011     0.000004     0.000008     0.000003     0.000008     0.000008     0.000009     0.000006     0.000010     0.000004     0.000007     0.000007     0.000005     0.000003     0.000005     0.000006     0.000004     0.000008     0.000004     0.000005     0.000004     0.000002     0.000003     0.000009     0.000006     0.000006     0.000007     0.000009     0.000106     0.000033 
 1095.699     0.000009     0.000010     0.000011     0.000012     0.000007     0.000012     0.000008     0.000008     0.000010     0.000012     0.000005     0.000006     0.000008     0.000010     0.000010     0.000009     0.000009     0.000009     0.000011     0.000006     0.000008     0.000008     0.000010     0.000009     0.000007     0.000004     0.000009     0.000010     0.000007     0.000007     0.000007     0.000008     0.000004     0.000004     0.000004     0.000007     0.000006     0.000001     0.000008     0.000009     0.000006     0.000006     0.000012     0.000008     0.000009     0.000005     0.000012     0.000134     0.000041 
 1098.707     0.000009     0.000008     0.000013     0.000006     0.000010     0.000012     0.000008     0.000008     0.000009     0.000010     0.000005     0.000008     0.000009     0.000009     0.000007     0.000005     0.000013     0.000010     0.000011     0.000009     0.000006     0.000011     0.000007     0.000008     0.000007     0.000011     0.000008     0.000014     0.000011     0.000002     0.000010     0.000010     0.000010     0.000007     0.000001     0.000008     0.000003     0.000004     0.000011     0.000007     0.000008     0.000005     0.000012     0.000007     0.000007     0.000012     0.000014     0.000142     0.000076 
 1101.713     0.000010     0.000012     0.000012     0.000013     0.000009     0.000013     0.000013     0.000009     0.000013     0.000014     0.000009     0.000010     0.000008     0.000010     0.000010     0.000008     0.000015     0.000007     0.000016     0.000011     0.000009     0.000007     0.000005     0.000012     0.000007     0.000011     0.000009     0.000009     0.000013     0.000009     0.000010     0.000005     0.000005     0.000011     0.000012     0.000011     0.000004     0.000005     0.000011     0.000006     0.000007     0.000002     0.000013     0.000005     0.000009     0.000005     0.000013     0.000143     0.000006 
 1104.718     0.000012     0.000010     0.000016     0.000010     0.000014     0.000016     0.000015     0.000014     0.000016     0.000018     0.000008     0.000013     0.000008     0.000008     0.000009     0.000015     0.000015     0.000014     0.000017     0.000009     0.000010     0.000009     0.000008     0.000008     0.000010     0.000010     0.000009     0.000010     0.000013     0.000006     0.000014     0.000005     0.000014     0.000009     0.000009     0.000010     0.000010     0.000007     0.000009     0.000013     0.000007     0.000005     0.000011     0.000009     0.000014     0.000011     0.000016     0.000170     0.000059 
 1107.722     0.000014     0.000015     0.000017     0.000015     0.000015     0.000020     0.000014     0.000011     0.000015     0.000022     0.000014     0.000013     0.000008     0.000019     0.000012     0.000012     0.000011     0.000015     0.000013     0.000011     0.000010     0.000013     0.000012     0.000010     0.000013     0.000009     0.000013     0.000014     0.000013     0.000015     0.000009     0.000005     0.000008     0.000011     0.000008     0.000009     0.000009     0.000008     0.000014     0.000009     0.000011     0.000011     0.000015     0.000009     0.000015     0.000013     0.000020     0.000162     0.000036 
 1110.725     0.000014     0.000061     0.000027     0.000018     0.000017     0.000022     0.000020     0.000019     0.000049     0.000019     0.000017     0.000020     0.000017     0.000021     0.000015     0.000012     0.000017     0.000015     0.000016     0.000013     0.000011     0.000011     0.000013     0.000016     0.000011     0.000017     0.000016     0.000016     0.000018     0.000017     0.000010     0.000008     0.000017     0.000010     0.000013     0.000019     0.000013     0.000015     0.000014     0.000014     0.000010     0.000013     0.000018     0.000012     0.000014     0.000008     0.000066     0.000244     0.000051 
 1113.727     0.000075     0.000055     0.000025     0.000029     0.000022     0.000071     0.000071     0.000024     0.000078     0.000075     0.000066     0.000026     0.000075     0.000081     0.000014     0.000014     0.000028     0.000016     0.000075     0.000018     0.000019     0.000025     0.000065     0.000012     0.000015     0.000016     0.000022     0.000023     0.000018     0.000017     0.000067     0.000015     0.000024     0.000019     0.000019     0.000019     0.000067     0.000062     0.000011     0.000017     0.000012     0.000016     0.000016     0.000015     0.000015     0.000024     0.000107     0.000245     0.000143 
 1116.728     0.000106     0.000130     0.000031     0.000136     0.000132     0.000130     0.000076     0.000068     0.000090     0.000081     0.000086     0.000080     0.000072     0.000124     0.000122     0.000021     0.000031     0.000020     0.000093     0.000022     0.000021     0.000132     0.000064     0.000019     0.000026     0.000021     0.000026     0.000081     0.000076     0.000023     0.000070     0.000018     0.000021     0.000019     0.000021     0.000026     0.000098     0.000006     0.000127     0.000020     0.000022     0.000021     0.000084     0.000019     0.000019     0.000082     0.000153     0.000329     0.000066 
 1119.728     0.000155     0.000170     0.000176     0.000171     0.000177     0.000218     0.000185     0.000158     0.000164     0.000151     0.000166     0.000149     0.000151     0.000148     0.000166     0.000155     0.000021     0.000168     0.000137     0.000173     0.000148     0.000139     0.000131     0.000155     0.000089     0.000089     0.000089     0.000137     0.000080     0.000153     0.000146     0.000023     0.000026     0.000017     0.000025     0.000034     0.000128     0.000149     0.000132     0.000034     0.000026     0.000087     0.000132     0.000030     0.000088     0.000185     0.000193     0.000378     0.000220 
 1122.726     0.000249     0.000252     0.000191     0.000239     0.000207     0.000231     0.000176     0.000248     0.000210     0.000179     0.000211     0.000240     0.000243     0.000161     0.000205     0.000173     0.000157     0.000180     0.000221     0.000192     0.000195     0.000207     0.000212     0.000159     0.000107     0.000163     0.000163     0.000158     0.000177     0.000185     0.000180     0.000171     0.000104     0.000095     0.000090     0.000133     0.000182     0.000166     0.000197     0.000103     0.000154     0.000223     0.000169     0.000177     0.000164     0.000249     0.000268     0.000389     0.000243 
 1125.724     0.000365     0.000338     0.000372     0.000351     0.000364     0.000390     0.000363     0.000353     0.000337     0.000271     0.000304     0.000332     0.000329     0.000350     0.000336     0.000314     0.000305     0.000282     0.000292     0.000257     0.000308     0.000332     0.000309     0.000237     0.000248     0.000229     0.000225     0.000263     0.000279     0.000317     0.000289     0.000240     0.000241     0.000177     0.000199     0.000209     0.000254     0.000263     0.000283     0.000136     0.000191     0.000327     0.000260     0.000260     0.000233     0.000402     0.000472     0.000664     0.000279 
 1128.720     0.000479     0.000530     0.000543     0.000575     0.000517     0.000546     0.000563     0.000492     0.000443     0.000483     0.000484     0.000493     0.000516     0.000551     0.000573     0.000405     0.000388     0.000438     0.000410     0.000410     0.000451     0.000448     0.000498     0.000401     0.000350     0.000332     0.000353     0.000336     0.000368     0.000429     0.000426     0.000351     0.000342     0.000224     0.000293     0.000286     0.000403     0.000400     0.000411     0.000339     0.000282     0.000472     0.000472     0.000388     0.000371     0.000654     0.000779     0.000783     0.000617 
 1131.770     0.000812     0.000831     0.000874     0.000883     0.000871     0.000848     0.000853     0.000813     0.000825     0.000776     0.000841     0.000790     0.000855     0.000861     0.000888     0.000655     0.000711     0.000653     0.000658     0.000721     0.000711     0.000791     0.000765     0.000599     0.000534     0.000531     0.000505     0.000610     0.000608     0.000708     0.000615     0.000579     0.000494     0.000383     0.000429     0.000512     0.000541     0.000701     0.000694     0.000447     0.000370     0.000671     0.000761     0.000612     0.000553     0.001100     0.001282     0.001084     0.000375 
 1134.764     0.001422     0.001389     0.001487     0.001443     0.001486     0.001434     0.001443     0.001376     0.001299     0.001223     0.001240     0.001329     0.001427     0.001513     0.001515     0.001200     0.001138     0.001002     0.001120     0.001195     0.001234     0.001349     0.001289     0.001050     0.000847     0.000836     0.000841     0.000934     0.001039     0.001174     0.001161     0.000840     0.000689     0.000643     0.000677     0.000821     0.001009     0.001159     0.001159     0.000814     0.000701     0.001225     0.001251     0.001047     0.000836     0.001937     0.002256     0.001833     0.000983 
 1137.757     0.002476     0.002483     0.002520     0.002470     0.002459     0.002445     0.002533     0.002386     0.002220     0.002181     0.002252     0.002418     0.002470     0.002494     0.002570     0.002020     0.001944     0.001822     0.001822     0.002032     0.002133     0.002302     0.002211     0.001721     0.001590     0.001287     0.001443     0.001589     0.001815     0.002061     0.001950     0.001589     0.001280     0.001012     0.001174     0.001359     0.001772     0.001984     0.001967     0.001356     0.001166     0.002134     0.002290     0.001815     0.001545     0.003653     0.004235     0.002181     0.001515 
 1140.749     0.004636     0.004500     0.004456     0.004480     0.004484     0.004487     0.004486     0.004303     0.004039     0.003989     0.004113     0.004351     0.004393     0.004544     0.004763     0.003744     0.003451     0.003174     0.003245     0.003547     0.003952     0.004125     0.004219     0.003021     0.002718     0.002432     0.002527     0.002967     0.003398     0.003724     0.003692     0.002754     0.002291     0.001877     0.002090     0.002567     0.003242     0.003736     0.003458     0.002431     0.001991     0.004072     0.004261     0.003372     0.002793     0.007135     0.008457     0.003811     0.001673 
 1143.741     0.008525     0.008442     0.008556     0.008564     0.008573     0.008500     0.008550     0.008139     0.007520     0.007550     0.007654     0.008090     0.008314     0.008627     0.009021     0.007012     0.006599     0.006009     0.006260     0.006933     0.007387     0.007815     0.007845     0.005587     0.005170     0.004453     0.004747     0.005552     0.006531     0.007013     0.006879     0.005190     0.004150     0.003449     0.003908     0.004810     0.006197     0.007110     0.006778     0.004382     0.003697     0.007984     0.008232     0.006661     0.005468     0.015455     0.017992     0.006748     0.004027 
 1146.784     0.016692     0.016605     0.016776     0.016753     0.016621     0.016747     0.016703     0.016007     0.014701     0.014635     0.015291     0.015990     0.016562     0.017042     0.017846     0.013612     0.012725     0.011612     0.012163     0.013631     0.014399     0.015622     0.015417     0.011167     0.009955     0.008590     0.009249     0.010763     0.012803     0.013933     0.013573     0.010181     0.008330     0.006589     0.007417     0.009438     0.012323     0.014446     0.013541     0.008571     0.007346     0.016637     0.017130     0.013855     0.011214     0.035241     0.040832     0.008448     0.004610 
 1149.773     0.034026     0.033933     0.033878     0.033787     0.033959     0.033809     0.033969     0.032589     0.029985     0.029763     0.030883     0.032382     0.033665     0.034631     0.036223     0.028078     0.025614     0.023489     0.024796     0.027861     0.029870     0.031941     0.031757     0.022525     0.019910     0.017383     0.018596     0.022179     0.026135     0.028892     0.028002     0.020904     0.016682     0.013231     0.015176     0.019408     0.025929     0.030305     0.028089     0.017813     0.015225     0.036664     0.037458     0.030698     0.025128     0.086401     0.099402     0.016950     0.007265 
 1152.761     0.072021     0.071322     0.071680     0.071644     0.071821     0.071307     0.071727     0.068741     0.063213     0.062684     0.065335     0.068703     0.071391     0.073661     0.077543     0.059168     0.053773     0.049242     0.051960     0.059041     0.063458     0.068055     0.067366     0.047728     0.042063     0.036040     0.039238     0.047262     0.056219     0.062087     0.059962     0.044625     0.035729     0.027679     0.032326     0.042123     0.057197     0.066985     0.061663     0.039125     0.033490     0.085622     0.087026     0.073313     0.060257     0.218241     0.248029     0.027872     0.018311 
 1155.801     0.160405     0.159658     0.159816     0.159985     0.160173     0.158955     0.159960     0.152988     0.140218     0.138458     0.145577     0.153327     0.159283     0.164611     0.174662     0.131578     0.120255     0.108787     0.115305     0.132135     0.142356     0.154145     0.152736     0.107343     0.092909     0.079837     0.087477     0.107121     0.128418     0.142737     0.137319     0.102314     0.080289     0.061393     0.072893     0.097381     0.134609     0.159311     0.144942     0.091905     0.078392     0.212873     0.213243     0.186982     0.153532     0.460856     0.511711     0.034587     0.019005 
 1158.786     0.357556     0.357477     0.356530     0.356779     0.356837     0.354365     0.356694     0.342395     0.316445     0.312230     0.326995     0.342726     0.355772     0.366598     0.387265     0.300848     0.275117     0.249315     0.265834     0.301746     0.324517     0.349293     0.346792     0.252488     0.217159     0.186425     0.204777     0.251741     0.299265     0.331798     0.320129     0.247060     0.188915     0.145416     0.174058     0.234354     0.318346     0.369537     0.342008     0.227983     0.193842     0.462347     0.469098     0.429810     0.358934     0.584365     0.632443     0.072448     0.036630 
 1161.771     0.627209     0.626390     0.628399     0.623813     0.628304     0.623699     0.628730     0.613222     0.588848     0.584910     0.596890     0.609040     0.621867     0.629297     0.647383     0.571531     0.542533     0.508381     0.526562     0.568857     0.590636     0.612132     0.611966     0.517958     0.469103     0.411359     0.439743     0.509983     0.564206     0.595303     0.588949     0.515892     0.423936     0.338268     0.388765     0.487229     0.576505     0.614870     0.605843     0.491545     0.425895     0.622435     0.649793     0.638687     0.568124     0.449651     0.475834     0.096571     0.070818 
 1164.807     0.654586     0.653542     0.656764     0.653578     0.657978     0.658290     0.657282     0.654348     0.671001     0.669992     0.660413     0.648818     0.644042     0.639300     0.630423     0.656722     0.670161     0.672399     0.663978     0.649493     0.637872     0.628138     0.633403     0.664997     0.666998     0.645230     0.647583     0.647602     0.630506     0.615027     0.632482     0.664616     0.651763     0.602702     0.623912     0.638467     0.604275     0.581669     0.613173     0.660143     0.620488     0.490221     0.522623     0.544556     0.532807     0.297533     0.312904     0.126670     0.060023 
 1167.790     0.463394     0.463619     0.463167     0.464015     0.462105     0.464956     0.462520     0.462831     0.488686     0.487696     0.474464     0.459909     0.450892     0.443842     0.431579     0.474643     0.498432     0.528325     0.505837     0.469284     0.449248     0.433773     0.439593     0.505055     0.540423     0.577787     0.549059     0.492379     0.445918     0.421340     0.439144     0.504118     0.553070     0.618914     0.571652     0.495968     0.417278     0.387685     0.414363     0.513643     0.526181     0.320610     0.338902     0.361075     0.364789     0.213309     0.223732     0.247026     0.152309 
 1170.771     0.314110     0.314519     0.314184     0.314407     0.313662     0.315205     0.313105     0.311657     0.326190     0.326610     0.319419     0.310868     0.304940     0.301203     0.293229     0.314036     0.328025     0.347595     0.334004     0.310164     0.300032     0.290716     0.293293     0.328942     0.353183     0.383731     0.360162     0.321494     0.293796     0.279957     0.289340     0.326072     0.368304     0.426021     0.380688     0.324161     0.276234     0.259759     0.274103     0.334033     0.348016     0.225242     0.235920     0.249397     0.251557     0.170502     0.180547     0.286804     0.223920 
 1173.804     0.233027     0.232450     0.233081     0.233393     0.232202     0.233505     0.232130     0.230498     0.237534     0.239138     0.234402     0.229720     0.227060     0.225290     0.220606     0.226870     0.234922     0.244289     0.237581     0.225725     0.220252     0.216442     0.217722     0.230598     0.240248     0.259413     0.246292     0.227392     0.213541     0.206036     0.210934     0.228449     0.251055     0.280227     0.254963     0.226732     0.202649     0.193993     0.202260     0.230636     0.239160     0.176419     0.183957     0.192458     0.191638     0.150854     0.161062     0.414854     0.235409 
 1176.783     0.193648     0.193662     0.193307     0.192276     0.193169     0.193334     0.193013     0.190544     0.194156     0.193865     0.192145     0.189844     0.187982     0.187817     0.185510     0.185691     0.186747     0.193738     0.187421     0.184329     0.181161     0.179319     0.180153     0.182886     0.185905     0.195090     0.189547     0.179857     0.173314     0.170654     0.173713     0.180746     0.185491     0.205858     0.191941     0.178183     0.166725     0.162822     0.167569     0.180347     0.184173     0.154429     0.159151     0.166279     0.161056     0.145659     0.156888     0.619531     0.491327 
 1179.814     0.176444     0.175679     0.175196     0.173314     0.174979     0.176476     0.174562     0.171621     0.173268     0.172107     0.171330     0.171806     0.171561     0.170334     0.172176     0.166692     0.165024     0.169645     0.167579     0.164839     0.164709     0.162915     0.162976     0.159443     0.160632     0.166458     0.161868     0.157869     0.155380     0.154528     0.158206     0.158949     0.157173     0.168302     0.162048     0.154631     0.149790     0.152106     0.152162     0.155797     0.156199     0.148557     0.154473     0.156648     0.148724     0.153125     0.165175     0.619965     0.490154 
 1182.790     0.176636     0.173455     0.175711     0.175795     0.175897     0.174932     0.176977     0.173600     0.171787     0.172813     0.171605     0.170659     0.172838     0.174814     0.174977     0.164039     0.163899     0.164990     0.164276     0.162409     0.162591     0.164884     0.166228     0.155361     0.155774     0.157302     0.153921     0.151989     0.152498     0.157247     0.157861     0.152821     0.153498     0.152405     0.149878     0.150225     0.152019     0.155192     0.156823     0.152573     0.148605     0.154220     0.160802     0.162002     0.149517     0.174414     0.193361     0.632830     0.558007 
 1185.819     0.193465     0.193871     0.191840     0.192747     0.187552     0.193580     0.190080     0.189095     0.182772     0.185095     0.180839     0.188593     0.188697     0.189675     0.188307     0.175442     0.170574     0.170204     0.171755     0.177040     0.177322     0.183332     0.181115     0.165209     0.162237     0.158104     0.160916     0.166223     0.169598     0.172927     0.170914     0.164574     0.158725     0.156136     0.153705     0.157786     0.161707     0.175223     0.173370     0.159327     0.153813     0.173205     0.184411     0.180191     0.169711     0.223599     0.245290     0.652781     0.631179 
 1188.793     0.226216     0.225431     0.223458     0.220819     0.225220     0.225673     0.221216     0.218573     0.211384     0.215769     0.213436     0.217358     0.216466     0.223711     0.226369     0.211396     0.199571     0.195178     0.201430     0.206670     0.209702     0.212793     0.213912     0.189685     0.180749     0.179947     0.178211     0.188723     0.195477     0.199818     0.207058     0.191899     0.167809     0.165646     0.170351     0.182139     0.200154     0.210707     0.202773     0.184484     0.171983     0.219992     0.231446     0.225774     0.201457     0.300246     0.330239     0.570068     0.627978 
 1191.820     0.284030     0.284935     0.287076     0.282159     0.286317     0.285274     0.289341     0.278209     0.270892     0.266770     0.271606     0.274789     0.281803     0.289441     0.291637     0.260859     0.251489     0.244685     0.247759     0.257802     0.261421     0.274810     0.275072     0.240966     0.231351     0.221040     0.222516     0.237581     0.252602     0.264311     0.262751     0.235364     0.216911     0.199472     0.207982     0.228984     0.251920     0.273286     0.268646     0.228458     0.213891     0.288336     0.308469     0.296962     0.264588     0.415192     0.461134     0.503334     0.469671 
 1194.845     0.373826     0.373174     0.375989     0.377921     0.377299     0.377598     0.375818     0.370574     0.357077     0.352634     0.360216     0.371939     0.371229     0.385397     0.386894     0.343685     0.331362     0.318927     0.322427     0.340086     0.352584     0.368060     0.369318     0.323790     0.302104     0.286188     0.296096     0.316668     0.338591     0.358986     0.353743     0.321703     0.296800     0.261914     0.274299     0.303125     0.338767     0.369975     0.364743     0.304349     0.284505     0.406562     0.424337     0.407641     0.369315     0.577537     0.621368     0.606415     0.582495 
 1197.815     0.510745     0.512150     0.505046     0.501685     0.504680     0.517096     0.503588     0.507651     0.482271     0.479741     0.492693     0.494828     0.505882     0.508383     0.523262     0.477026     0.456985     0.438840     0.452882     0.469774     0.486310     0.500234     0.495899     0.444933     0.404604     0.386045     0.399442     0.429915     0.455823     0.489399     0.488535     0.442754     0.389159     0.356012     0.378049     0.420771     0.481101     0.511052     0.506180     0.418937     0.397445     0.561781     0.579443     0.573078     0.520814     0.693276     0.717523     0.514956     0.498256 
 1200.838     0.645334     0.647852     0.643238     0.650393     0.639614     0.639521     0.632352     0.633475     0.623956     0.625781     0.625154     0.630832     0.641833     0.643571     0.660321     0.612183     0.588356     0.570517     0.593736     0.604074     0.616714     0.629889     0.629820     0.584397     0.539706     0.526689     0.541040     0.573117     0.600525     0.619625     0.611876     0.586095     0.523988     0.484281     0.517973     0.570605     0.614870     0.643142     0.635526     0.590695     0.554689     0.676572     0.685761     0.722936     0.661846     0.684307     0.689457     0.579413     0.463269 