# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     1.490000     1.490000     2.110000     2.500000     1.320000     1.320000     2.500000 
# z_pos      57.000000    56.000000    56.000000    57.000000    58.000000    55.000000    55.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       421          422          423          424          425          426          427          428      
#
# lambda for peak transmission
#          582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000 
# peak transmission
#            0.9230560    0.9105450    0.9226470    0.9318700    0.9199940    0.9037100    0.9220720    0.9373550 
# lambda blue with 1/2 of peak transmission
#          502.6982262  502.4742070  502.7529077  502.9559482  502.6227698  502.2304740  502.7476333  502.7753222 
# lambda red  with 1/2 of peak transmission
#          599.2972651  599.6497985  599.5094520  599.0173184  599.2843628  599.8958722  599.6704855  598.1909104 
# half width                              
#           96.5990389   97.1755915   96.7565443   96.0613702   96.6615929   97.6653983   96.9228522   95.4155881 
# central wavelength                      
#          550.9977457  551.0620028  551.1311799  550.9866333  550.9535663  551.0631731  551.2090594  550.4831163 
# central wavelength calculated as SAGEM (mean frequency)
#          546.7638925  546.7779587  546.8845372  546.7996956  546.7138880  546.7358425  546.9484077  546.3485052 
# lambda blue with 80% of peak transmission
#          507.6349567  506.4822221  506.7501169  509.1886643  507.2930286  506.1539440  506.6312962  509.4779838 
# lambda red  with 80% of peak transmission
#          596.9576283  597.2762842  597.2224407  596.5796804  596.8502125  597.3922676  597.3439320  595.5647649 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8650824    0.8531419    0.8649215    0.8755518    0.8600723    0.8471577    0.8672675    0.8800574 
# ATB calculated from points above 50%
#            0.8492671    0.8464390    0.8570505    0.8570856    0.8446503    0.8413885    0.8593064    0.8584050 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.483116 at column =  9, at id = 428 
# maxCWL      = 551.209059 at column =  8, at id = 427 
# difference =    0.7259431 
# minBW       = 95.415588 at column =  9, at id = 428 
# maxBW       = 97.665398 at column =  7, at id = 426 
# difference =    2.2498101 
# minATB80    = 0.847158 at column =  7, at id = 426 
# maxATB80    = 0.880057 at column =  9, at id = 428 
# difference =    0.0328997 
# minBlueEdge = 502.230474 at column =  7, at id = 426 
# maxBlueEdge = 502.955948 at column =  5, at id = 424 
# difference =    0.7254742 
# minRedEdge  = 598.190910 at column =  9, at id = 428 
# maxRedEdge  = 599.895872 at column =  7, at id = 426 
# difference =    1.7049619 
# minABR      = 9.999900 at column =  2, at id = 421 
# maxABR      = 9.999900 at column =  2, at id = 421 
# difference =    0.0000000 
  449.837     0.000001     0.000067     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  452.830    -0.000000     0.000082     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001 
  455.878    -0.000001     0.000099     0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  458.870    -0.000000     0.000130     0.000001     0.000000     0.000002     0.000001     0.000002     0.000001 
  461.862     0.000000     0.000173     0.000001     0.000000     0.000002     0.000001     0.000002    -0.000000 
  464.853     0.000001     0.000236     0.000001     0.000001     0.000002     0.000001     0.000003     0.000001 
  467.901     0.000001     0.000344     0.000001     0.000001     0.000002     0.000001     0.000002     0.000001 
  470.891     0.000019     0.000502     0.000019     0.000017     0.000023     0.000021     0.000018     0.000021 
  473.881     0.000034     0.000713     0.000040     0.000031     0.000032     0.000042     0.000041     0.000026 
  476.871     0.000061     0.000995     0.000057     0.000054     0.000061     0.000069     0.000060     0.000053 
  479.916     0.000134     0.001417     0.000135     0.000121     0.000138     0.000163     0.000137     0.000123 
  482.905     0.000419     0.002089     0.000416     0.000372     0.000428     0.000514     0.000418     0.000370 
  485.894     0.000580     0.002800     0.000578     0.000504     0.000600     0.000734     0.000597     0.000492 
  488.882     0.001707     0.004668     0.001690     0.001503     0.001760     0.002136     0.001704     0.001499 
  491.925     0.004576     0.008335     0.004404     0.003979     0.004800     0.005792     0.004392     0.004426 
  494.913     0.016190     0.021819     0.015808     0.013923     0.016896     0.020748     0.015934     0.014576 
  497.899     0.061535     0.072606     0.059319     0.053101     0.064573     0.079079     0.059447     0.058523 
  500.942     0.236197     0.263312     0.229742     0.206019     0.245557     0.292744     0.231570     0.219940 
  503.928     0.619313     0.637409     0.611596     0.591386     0.626524     0.661479     0.611041     0.625068 
  506.913     0.735038     0.743788     0.745420     0.727150     0.733827     0.743936     0.750852     0.712693 
  509.954     0.749388     0.750641     0.755833     0.751666     0.751177     0.750059     0.759021     0.756786 
  512.939     0.769224     0.767878     0.772056     0.767059     0.770825     0.764490     0.774927     0.771684 
  515.923     0.801516     0.797536     0.805603     0.804179     0.799715     0.790034     0.807160     0.800287 
  518.963     0.758223     0.758006     0.762375     0.760065     0.758806     0.756658     0.764624     0.767139 
  521.946     0.842021     0.835904     0.841480     0.846833     0.842581     0.833149     0.842483     0.856513 
  524.929     0.849198     0.844469     0.852131     0.856663     0.845573     0.837009     0.853072     0.866276 
  527.967     0.870561     0.865667     0.880370     0.886458     0.864424     0.855124     0.881016     0.893599 
  530.949     0.860895     0.855241     0.869664     0.874511     0.858376     0.846113     0.871861     0.881219 
  533.987     0.872403     0.864674     0.875233     0.880855     0.872595     0.858633     0.877118     0.883580 
  536.968     0.879315     0.870368     0.878787     0.886857     0.877802     0.862797     0.879091     0.898107 
  539.948     0.878103     0.874178     0.885476     0.887716     0.866751     0.863988     0.886621     0.885441 
  542.984     0.850423     0.856175     0.870318     0.869881     0.828534     0.847804     0.871831     0.875268 
  545.964     0.836683     0.850205     0.872308     0.863697     0.811351     0.841271     0.877188     0.861966 
  548.999     0.842286     0.853005     0.877432     0.866639     0.823703     0.843721     0.884445     0.868479 
  551.977     0.850950     0.854592     0.874381     0.865880     0.840718     0.844824     0.882385     0.865426 
  555.012     0.872563     0.868104     0.883881     0.883886     0.866988     0.858790     0.888554     0.887132 
  557.989     0.863620     0.861130     0.872881     0.871165     0.860218     0.855847     0.877123     0.869141 
  561.023     0.861213     0.855749     0.867503     0.873099     0.858267     0.852304     0.869324     0.884103 
  563.999     0.900833     0.892186     0.903812     0.911066     0.899765     0.887054     0.904835     0.923626 
  567.032     0.914060     0.906354     0.917471     0.922585     0.911677     0.901313     0.919447     0.922719 
  570.007     0.891892     0.883229     0.895781     0.902316     0.886576     0.874892     0.896351     0.908802 
  573.038     0.903183     0.895185     0.908989     0.917344     0.897685     0.888984     0.908836     0.924132 
  576.013     0.896805     0.889772     0.903348     0.906661     0.894755     0.884716     0.905318     0.910360 
  579.043     0.911699     0.899378     0.911434     0.920447     0.911766     0.895467     0.911783     0.931518 
  582.017     0.923056     0.910545     0.922647     0.931870     0.919994     0.903710     0.922072     0.937355 
  585.046     0.917811     0.907758     0.921387     0.929503     0.914220     0.901646     0.921211     0.936561 
  588.019     0.915754     0.903307     0.919626     0.927461     0.914452     0.895385     0.920314     0.933963 
  591.047     0.907412     0.890977     0.906253     0.918398     0.904259     0.880525     0.905597     0.925059 
  594.019     0.898086     0.888147     0.900870     0.907845     0.890351     0.882700     0.899304     0.896700 
  597.046     0.733644     0.754939     0.759472     0.715931     0.725321     0.760465     0.773081     0.609197 
  600.073     0.367763     0.406567     0.393118     0.332057     0.366516     0.432674     0.413178     0.237681 
  603.043     0.106219     0.127480     0.117323     0.087748     0.106678     0.141105     0.127908     0.053121 
  606.068     0.025801     0.030934     0.028019     0.021808     0.025994     0.035436     0.030160     0.015139 
  609.038     0.008244     0.010086     0.009051     0.006790     0.008305     0.011275     0.009846     0.004332 
  612.062     0.002523     0.003156     0.002717     0.002127     0.002559     0.003546     0.002931     0.001543 
  615.086     0.001030     0.001363     0.001120     0.000868     0.001041     0.001399     0.001214     0.000587 
  618.053     0.000368     0.000571     0.000396     0.000313     0.000375     0.000505     0.000427     0.000228 
  621.076     0.000197     0.000369     0.000211     0.000168     0.000201     0.000274     0.000227     0.000128 
  624.099     0.000096     0.000246     0.000100     0.000073     0.000095     0.000124     0.000106     0.000056 
  627.064     0.000058     0.000203     0.000059     0.000047     0.000058     0.000075     0.000061     0.000042 
  630.086     0.000037     0.000191     0.000040     0.000032     0.000040     0.000052     0.000046     0.000023 
  633.106     0.000023     0.000166     0.000023     0.000019     0.000018     0.000026     0.000021     0.000012 
  636.071     0.000006     0.000156     0.000011     0.000011     0.000012     0.000015     0.000007     0.000005 
  639.090     0.000012     0.000160     0.000013     0.000006     0.000007     0.000016     0.000011     0.000002 
  642.109     0.000005     0.000156     0.000011     0.000002     0.000006     0.000003     0.000006     0.000001 
  645.128     0.000000     0.000156     0.000001     0.000001     0.000003     0.000003     0.000001     0.000001 
  648.090     0.000002     0.000155     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001 
  651.107     0.000002     0.000157     0.000002     0.000002     0.000003     0.000003     0.000002     0.000002 
  654.123     0.000002     0.000152     0.000002     0.000001     0.000001     0.000002     0.000002     0.000000 
  657.139     0.000000     0.000151     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000 
  660.099     0.000000     0.000162     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000 