# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 301
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     1.840000     1.320000     1.840000     2.230000     2.000000     0.870000     2.000000     2.690000     2.230000     0.410000     2.230000     3.140000 
# z_pos      44.000000    45.000000    43.000000    45.000000    47.000000    46.000000    42.000000    46.000000    48.000000    47.000000    41.000000    47.000000    49.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       402          403          404          405          406          407          408          409          410          411          412          413          414      
#
# lambda for peak transmission
#          567.0320000  567.0320000  567.0320000  567.0320000  582.0170000  567.0320000  567.0320000  582.0170000  582.0170000  567.0320000  567.0320000  563.9990000  582.0170000 
# peak transmission
#            0.7181321    0.7146837    0.7141247    0.7230300    0.7220002    0.7067939    0.7092057    0.7227522    0.7229359    0.7027975    0.7069136    0.7245124    0.7239622 
# lambda blue with 1/2 of peak transmission
#          502.5773881  502.4299784  502.4665890  502.8240495  502.7618768  501.9303271  501.9811813  502.7414147  502.6331421  502.5988695  502.6859584  502.6113722  502.5187071 
# lambda red  with 1/2 of peak transmission
#          599.4066655  599.6054232  599.7874859  599.3042981  599.1899256  599.3038078  599.6485491  598.8778891  598.6199261  600.4498312  600.9752598  598.4447119  598.1279419 
# half width                              
#           96.8292775   97.1754448   97.3208969   96.4802485   96.4280488   97.3734808   97.6673678   96.1364745   95.9867839   97.8509616   98.2893015   95.8333397   95.6092348 
# central wavelength                      
#          550.9920268  551.0177008  551.1270375  551.0641738  550.9759012  550.6170675  550.8148652  550.8096519  550.6265341  551.5243504  551.8306091  550.5280420  550.3233245 
# central wavelength calculated as SAGEM (mean frequency)
#          546.7379231  546.7333253  546.8306791  546.8412363  546.7568562  546.3120816  546.4854093  546.6148172  546.4433618  547.1841926  547.4539097  546.3574875  546.1707085 
# lambda blue with 80% of peak transmission
#          506.0275819  505.8007818  505.7200178  506.3295282  506.3807070  504.5529295  504.6004850  506.5314008  506.7226475  505.9308146  505.7924100  506.6206839  507.0140390 
# lambda red  with 80% of peak transmission
#          597.1203063  597.2274104  597.3989084  597.0789911  596.8059407  596.6589177  597.1800068  596.3386873  595.9202434  597.7186444  598.1609301  595.7739436  595.4281601 
# lambda blue with 0.0001 of peak transmission
#          478.0684223  477.7364114  477.9003422  478.4567261  478.3650703  477.1262128  477.2310212  478.4140158  478.4394248  477.8142588  477.8816623  478.2295021  478.1166413 
# lambda red  with 0.0001 of peak transmission
#          624.1878182  624.9765294  625.1096739  623.9899102  623.7444931  624.8527392  625.6724462  623.2983773  622.9725754  626.3598587  626.9759473  622.7027770  622.5086659 
# ATB calculated from points above 80%
#            0.6834998    0.6779505    0.6819148    0.6889272    0.6869916    0.6738135    0.6784791    0.6921336    0.6851641    0.6613135    0.6751709    0.6949448    0.6864097 
# ATB calculated from points above 50%
#            0.6777961    0.6727871    0.6764989    0.6822974    0.6768595    0.6662158    0.6746134    0.6810555    0.6739674    0.6472719    0.6615605    0.6829053    0.6706399 
# ABR calculated from points below and above 0.0001
#            0.0000359    0.0000443    0.0000132    0.0000468    0.0000160    0.0000274    0.0000566    0.0000411    0.0000166    0.0000347    0.0000293    0.0000217    0.0000297 
# minCWL      = 550.323324 at column = 14, at id = 414 
# maxCWL      = 551.830609 at column = 12, at id = 412 
# difference =    1.5072846 
# minBW       = 95.609235 at column = 14, at id = 414 
# maxBW       = 98.289301 at column = 12, at id = 412 
# difference =    2.6800667 
# minATB80    = 0.661313 at column = 11, at id = 411 
# maxATB80    = 0.694945 at column = 13, at id = 413 
# difference =    0.0336313 
# minBlueEdge = 501.930327 at column =  7, at id = 407 
# maxBlueEdge = 502.824050 at column =  5, at id = 405 
# difference =    0.8937224 
# minRedEdge  = 598.127942 at column = 14, at id = 414 
# maxRedEdge  = 600.975260 at column = 12, at id = 412 
# difference =    2.8473179 
# minABR      = 0.000013 at column =  4, at id = 404 
# maxABR      = 0.000057 at column =  8, at id = 408 
# difference =    0.0000434 
  299.645     0.000262     0.000300    -0.000124     0.000486     0.000074     0.000041     0.000432     0.000296     0.000011     0.000011     0.000110     0.000229     0.000035 
  302.654    -0.000001     0.000036    -0.000092     0.000013    -0.000038    -0.000092    -0.000045     0.000050     0.000003    -0.000067    -0.000069    -0.000050     0.000023 
  305.662     0.000028     0.000010    -0.000046    -0.000023    -0.000027     0.000013    -0.000001     0.000011    -0.000006    -0.000034    -0.000056    -0.000012    -0.000002 
  308.671    -0.000015    -0.000019    -0.000012    -0.000011    -0.000013    -0.000017    -0.000010     0.000002     0.000017    -0.000019    -0.000010    -0.000013     0.000028 
  311.679    -0.000012     0.000002    -0.000017    -0.000001     0.000002    -0.000021    -0.000008     0.000002    -0.000012    -0.000023    -0.000031     0.000005     0.000006 
  314.687    -0.000010     0.000018    -0.000008     0.000003    -0.000028     0.000006     0.000003     0.000002    -0.000006    -0.000002    -0.000012    -0.000002    -0.000010 
  317.694     0.000010    -0.000012     0.000013     0.000016    -0.000018     0.000005     0.000013     0.000001    -0.000005    -0.000012    -0.000016    -0.000012     0.000009 
  320.702     0.000015    -0.000001    -0.000003     0.000011    -0.000015    -0.000010    -0.000012     0.000022    -0.000006    -0.000019    -0.000013    -0.000006     0.000001 
  323.709     0.000004    -0.000011    -0.000006    -0.000002    -0.000009    -0.000011    -0.000000     0.000009    -0.000009    -0.000024    -0.000013    -0.000007    -0.000005 
  326.716     0.000005    -0.000002    -0.000009     0.000007    -0.000005    -0.000007    -0.000000     0.000008    -0.000005    -0.000008     0.000000    -0.000011     0.000010 
  329.665    -0.000006     0.000007    -0.000008     0.000006    -0.000001    -0.000007    -0.000000     0.000008     0.000000    -0.000007     0.000000    -0.000002     0.000002 
  332.672    -0.000002    -0.000005    -0.000007     0.000005    -0.000007     0.000002    -0.000000     0.000012    -0.000004    -0.000009     0.000001    -0.000002     0.000004 
  335.678    -0.000000    -0.000002    -0.000007    -0.000000    -0.000004    -0.000004     0.000006     0.000006    -0.000006     0.000001     0.000000    -0.000006     0.000009 
  338.683    -0.000001    -0.000001    -0.000004    -0.000004    -0.000005    -0.000007     0.000002     0.000007    -0.000008    -0.000002    -0.000002    -0.000002     0.000004 
  341.689    -0.000000    -0.000005    -0.000003     0.000003    -0.000006     0.000001     0.000004     0.000006    -0.000006    -0.000005     0.000002    -0.000003    -0.000001 
  344.694     0.000001    -0.000001    -0.000002     0.000003    -0.000004    -0.000007     0.000004     0.000004     0.000001    -0.000004     0.000003    -0.000006     0.000002 
  347.699    -0.000002    -0.000003    -0.000005     0.000001    -0.000005    -0.000000     0.000001     0.000001    -0.000004     0.000002     0.000001    -0.000005    -0.000003 
  350.703    -0.000005     0.000002    -0.000005    -0.000004    -0.000007    -0.000001     0.000001     0.000003    -0.000001    -0.000001     0.000001    -0.000005     0.000001 
  353.707    -0.000004    -0.000004     0.000001    -0.000001    -0.000004    -0.000001     0.000003     0.000003     0.000001     0.000005     0.000002    -0.000002     0.000002 
  356.711    -0.000000    -0.000004     0.000001    -0.000002     0.000002    -0.000003     0.000001    -0.000000    -0.000001     0.000003    -0.000002     0.000001     0.000001 
  359.715     0.000003    -0.000001    -0.000002    -0.000001    -0.000001    -0.000003     0.000001    -0.000000    -0.000003     0.000000     0.000001    -0.000003     0.000003 
  362.718     0.000002     0.000000    -0.000002     0.000003    -0.000003    -0.000001    -0.000003     0.000002     0.000000    -0.000001     0.000003    -0.000002     0.000003 
  365.721     0.000001     0.000000    -0.000002    -0.000001    -0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000000     0.000005    -0.000003     0.000004 
  368.724     0.000002     0.000001    -0.000003    -0.000002     0.000001    -0.000001    -0.000001     0.000001    -0.000002     0.000001     0.000001    -0.000002     0.000003 
  371.726     0.000002     0.000001    -0.000001    -0.000001     0.000003    -0.000001    -0.000001    -0.000001     0.000001     0.000001     0.000002    -0.000003     0.000004 
  374.728     0.000000     0.000001     0.000000    -0.000001     0.000001    -0.000001    -0.000001     0.000001     0.000000    -0.000001     0.000001    -0.000001     0.000004 
  377.730     0.000001     0.000001     0.000002     0.000001     0.000000    -0.000002    -0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000005 
  380.788     0.000002     0.000001     0.000001    -0.000001    -0.000001    -0.000001    -0.000000     0.000001    -0.000001     0.000000     0.000003    -0.000001     0.000001 
  383.789     0.000000     0.000000    -0.000001     0.000001    -0.000002    -0.000001     0.000002     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000001 
  386.789    -0.000000     0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000000    -0.000001     0.000001     0.000000     0.000001     0.000002 
  389.790    -0.000002     0.000001    -0.000002     0.000001    -0.000001     0.000001     0.000002    -0.000002    -0.000000     0.000002     0.000001     0.000000     0.000002 
  392.790     0.000001     0.000001    -0.000001     0.000002     0.000001    -0.000001    -0.000000    -0.000001     0.000000     0.000002     0.000001     0.000000     0.000003 
  395.790     0.000001     0.000001     0.000000     0.000002    -0.000002    -0.000001    -0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000002 
  398.789    -0.000000     0.000001    -0.000000     0.000002    -0.000002    -0.000002     0.000001     0.000000    -0.000001    -0.000001     0.000002     0.000000     0.000004 
  401.788    -0.000000     0.000002     0.000000     0.000001    -0.000002    -0.000002    -0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000002 
  404.787     0.000001     0.000000    -0.000001     0.000001    -0.000001    -0.000001     0.000002     0.000000     0.000000     0.000001     0.000001    -0.000002     0.000002 
  407.785     0.000002     0.000000     0.000001     0.000002    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002 
  410.783     0.000001     0.000002     0.000001     0.000000    -0.000000    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001 
  413.781     0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000001     0.000002     0.000001    -0.000000     0.000001     0.000002    -0.000000     0.000001 
  416.834     0.000000     0.000001     0.000001     0.000002    -0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000001 
  419.831     0.000002     0.000002     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000002 
  422.828     0.000001     0.000002     0.000001     0.000001    -0.000001    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000001     0.000002 
  425.824     0.000001     0.000002     0.000000    -0.000000    -0.000001    -0.000001     0.000002    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001 
  428.820     0.000001     0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000002     0.000000    -0.000001     0.000001 
  431.815     0.000001     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  434.810     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  437.862     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001 
  440.856     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000000     0.000001 
  443.850    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000002     0.000000    -0.000001     0.000001 
  446.844     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000002     0.000001    -0.000001     0.000002 
  449.837     0.000000     0.000002     0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000002 
  452.830     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000002     0.000001     0.000002     0.000001     0.000000     0.000001 
  455.878     0.000001     0.000002     0.000001     0.000000     0.000002     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000001    -0.000000     0.000001 
  458.870    -0.000000     0.000001     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001 
  461.862     0.000000     0.000002     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001 
  464.853     0.000001     0.000002     0.000001     0.000002     0.000000     0.000000     0.000001     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002 
  467.901     0.000001     0.000002     0.000001     0.000001     0.000000     0.000007     0.000007     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002 
  470.891     0.000017     0.000017     0.000015     0.000017     0.000014     0.000018     0.000018     0.000017     0.000015     0.000017     0.000010     0.000015     0.000018 
  473.881     0.000035     0.000036     0.000037     0.000028     0.000032     0.000035     0.000032     0.000031     0.000027     0.000039     0.000045     0.000023     0.000025 
  476.871     0.000047     0.000053     0.000048     0.000041     0.000045     0.000065     0.000062     0.000044     0.000045     0.000049     0.000044     0.000050     0.000050 
  479.916     0.000110     0.000118     0.000117     0.000101     0.000101     0.000138     0.000137     0.000100     0.000098     0.000118     0.000125     0.000101     0.000104 
  482.905     0.000339     0.000367     0.000363     0.000304     0.000312     0.000429     0.000440     0.000309     0.000309     0.000354     0.000351     0.000308     0.000313 
  485.894     0.000469     0.000514     0.000516     0.000425     0.000427     0.000605     0.000611     0.000408     0.000419     0.000553     0.000589     0.000407     0.000426 
  488.882     0.001362     0.001481     0.001475     0.001223     0.001251     0.001789     0.001803     0.001230     0.001266     0.001438     0.001438     0.001240     0.001272 
  491.925     0.003551     0.003880     0.003768     0.003122     0.003213     0.005165     0.004983     0.003258     0.003515     0.003562     0.003458     0.003483     0.003801 
  494.913     0.012839     0.014108     0.013890     0.011371     0.011548     0.018031     0.017733     0.011417     0.011951     0.013629     0.013469     0.011732     0.012623 
  497.899     0.048851     0.053313     0.051961     0.042726     0.043904     0.070539     0.068324     0.044160     0.047075     0.049302     0.046941     0.047068     0.051388 
  500.942     0.188505     0.203953     0.200014     0.167104     0.171536     0.253103     0.248136     0.169181     0.179288     0.192303     0.186035     0.177724     0.190788 
  503.928     0.499926     0.511766     0.507603     0.475550     0.482403     0.556119     0.554060     0.488115     0.500957     0.479024     0.472694     0.507796     0.514997 
  506.913     0.605957     0.607369     0.613704     0.603418     0.598260     0.600619     0.613114     0.591406     0.583620     0.603046     0.621330     0.587406     0.577980 
  509.954     0.615619     0.611754     0.614577     0.615185     0.611917     0.614796     0.621365     0.613388     0.610872     0.600120     0.610267     0.619053     0.613781 
  512.939     0.628168     0.627253     0.628511     0.627796     0.625703     0.627162     0.629794     0.623329     0.624805     0.616803     0.625277     0.627721     0.627474 
  515.923     0.653947     0.651472     0.653450     0.658078     0.654784     0.643106     0.648193     0.652054     0.649596     0.635119     0.642221     0.652190     0.645335 
  518.963     0.618470     0.616148     0.618687     0.619619     0.616623     0.618000     0.621597     0.615991     0.615994     0.607806     0.617590     0.621343     0.621047 
  521.946     0.683049     0.679083     0.677827     0.684474     0.683568     0.681425     0.681398     0.686268     0.688036     0.662439     0.661685     0.692372     0.691255 
  524.929     0.689189     0.684544     0.685735     0.693832     0.690502     0.678313     0.682492     0.691861     0.689408     0.668512     0.677643     0.697898     0.692234 
  527.967     0.708485     0.698988     0.703577     0.717452     0.709448     0.689439     0.699637     0.717961     0.707654     0.674429     0.688039     0.722606     0.707423 
  530.949     0.697522     0.689422     0.694375     0.706390     0.699333     0.682961     0.690639     0.707043     0.700632     0.673203     0.685111     0.710678     0.700587 
  533.987     0.702680     0.697350     0.698062     0.708790     0.705010     0.693631     0.694592     0.707469     0.707050     0.687298     0.690091     0.708665     0.705503 
  536.968     0.704829     0.700586     0.699768     0.709353     0.708358     0.697409     0.696553     0.710739     0.712217     0.684566     0.687411     0.715948     0.715234 
  539.948     0.707708     0.701118     0.705049     0.714029     0.709020     0.685087     0.696388     0.709790     0.698242     0.680045     0.695058     0.709559     0.692564 
  542.984     0.690840     0.679667     0.689635     0.697827     0.686130     0.662080     0.688597     0.698832     0.671432     0.642694     0.678805     0.703466     0.664786 
  545.964     0.685682     0.669645     0.687989     0.696886     0.676038     0.647829     0.687885     0.698185     0.656095     0.630522     0.685120     0.700749     0.642206 
  548.999     0.685178     0.669885     0.688182     0.697776     0.675767     0.656612     0.692666     0.702823     0.665473     0.630134     0.681621     0.707614     0.649854 
  551.977     0.683960     0.673301     0.685779     0.694733     0.678820     0.663418     0.686271     0.696060     0.674106     0.647599     0.686260     0.698746     0.659407 
  555.012     0.693783     0.686386     0.691508     0.702443     0.693726     0.680579     0.691098     0.704656     0.695088     0.661706     0.683553     0.708497     0.684628 
  557.989     0.685963     0.681323     0.685307     0.691203     0.685268     0.672858     0.681840     0.689181     0.682509     0.670384     0.687194     0.689316     0.675142 
  561.023     0.681253     0.675852     0.677601     0.686688     0.682431     0.672471     0.678063     0.689966     0.687281     0.663234     0.674651     0.695452     0.687589 
  563.999     0.708861     0.703579     0.703557     0.713327     0.710495     0.702605     0.704125     0.717597     0.716825     0.685499     0.689695     0.724512     0.719359 
  567.032     0.718132     0.714684     0.714125     0.723030     0.719712     0.706794     0.709206     0.721838     0.720154     0.702797     0.706914     0.723115     0.716974 
  570.007     0.699315     0.694385     0.695662     0.705405     0.702047     0.684046     0.688575     0.704996     0.702169     0.678992     0.688730     0.708348     0.701918 
  573.038     0.708383     0.701574     0.703529     0.715069     0.710373     0.694885     0.699982     0.716939     0.711858     0.679329     0.687728     0.721130     0.711599 
  576.013     0.701650     0.696434     0.700573     0.708596     0.703168     0.689461     0.694707     0.708039     0.703806     0.686402     0.694798     0.709477     0.703523 
  579.043     0.708907     0.705001     0.703262     0.714211     0.712697     0.702858     0.700637     0.716857     0.719288     0.690528     0.691322     0.720535     0.722860 
  582.017     0.717375     0.713020     0.712324     0.722696     0.722000     0.704357     0.704028     0.722752     0.722936     0.697169     0.699672     0.724053     0.723962 
  585.046     0.714874     0.708566     0.710102     0.720459     0.717162     0.700304     0.703426     0.721831     0.718255     0.692232     0.698008     0.723569     0.719993 
  588.019     0.710947     0.704666     0.707286     0.718172     0.714943     0.696564     0.699157     0.719950     0.717636     0.689675     0.694447     0.721656     0.718936 
  591.047     0.701617     0.695893     0.695709     0.708333     0.707889     0.685562     0.684644     0.708459     0.710849     0.677755     0.680883     0.709554     0.710190 
  594.019     0.695999     0.690818     0.692238     0.701173     0.699180     0.679615     0.684371     0.698008     0.691432     0.668080     0.675116     0.693141     0.681443 
  597.046     0.581507     0.588103     0.602953     0.581640     0.567128     0.548693     0.578915     0.541671     0.511390     0.613936     0.645036     0.497318     0.461751 
  600.073     0.296279     0.315184     0.331454     0.286587     0.276097     0.286863     0.318020     0.243753     0.223057     0.381287     0.429181     0.205026     0.182620 
  603.043     0.086093     0.097674     0.105736     0.080630     0.077009     0.083155     0.096934     0.061382     0.055103     0.145724     0.179916     0.047234     0.041218 
  606.068     0.020560     0.023305     0.024795     0.019112     0.018360     0.021820     0.024928     0.015664     0.014410     0.034115     0.042476     0.012960     0.011693 
  609.038     0.006611     0.007575     0.008122     0.006162     0.005831     0.006727     0.007842     0.004777     0.004308     0.011351     0.014294     0.003778     0.003363 
  612.062     0.002012     0.002277     0.002417     0.001847     0.001770     0.002209     0.002522     0.001538     0.001423     0.003311     0.004062     0.001308     0.001199 
  615.086     0.000827     0.000929     0.001000     0.000767     0.000731     0.000845     0.000985     0.000619     0.000567     0.001354     0.001684     0.000510     0.000456 
  618.053     0.000293     0.000328     0.000348     0.000269     0.000257     0.000316     0.000360     0.000224     0.000208     0.000462     0.000569     0.000191     0.000180 
  621.076     0.000154     0.000174     0.000183     0.000142     0.000137     0.000172     0.000194     0.000121     0.000112     0.000238     0.000282     0.000105     0.000099 
  624.099     0.000073     0.000082     0.000083     0.000070     0.000064     0.000078     0.000088     0.000055     0.000048     0.000109     0.000133     0.000045     0.000043 
  627.064     0.000042     0.000047     0.000048     0.000039     0.000039     0.000049     0.000056     0.000036     0.000034     0.000058     0.000069     0.000030     0.000032 
  630.086     0.000029     0.000033     0.000032     0.000026     0.000027     0.000035     0.000037     0.000023     0.000024     0.000044     0.000051     0.000020     0.000021 
  633.106     0.000016     0.000016     0.000018     0.000015     0.000012     0.000016     0.000017     0.000008     0.000013     0.000024     0.000031     0.000010     0.000014 
  636.071     0.000008     0.000008     0.000009     0.000005     0.000003     0.000009     0.000011     0.000005     0.000001     0.000011     0.000015     0.000005     0.000006 
  639.090     0.000007     0.000010     0.000008     0.000008     0.000007     0.000009     0.000010     0.000005     0.000004     0.000009     0.000010     0.000004     0.000007 
  642.109     0.000007     0.000010     0.000008     0.000008     0.000004     0.000008     0.000009     0.000001     0.000001     0.000007     0.000011     0.000004     0.000001 
  645.128     0.000001     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000002     0.000001     0.000001     0.000003     0.000002     0.000001 
  648.090     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000003     0.000001     0.000001 
  651.107     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002     0.000003     0.000001     0.000002 
  654.123     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000003     0.000001     0.000001 
  657.139     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001 
  660.099     0.000001     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001 
  663.114     0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  666.129     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001 
  669.142     0.000000     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 
  672.155     0.000000     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000001 
  675.168    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  678.124     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001 
  681.136    -0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  684.146     0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  687.157     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  690.166     0.000000     0.000001     0.000001    -0.000000    -0.000000    -0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001 
  693.175     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 
  696.183    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  699.191    -0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000 
  702.198    -0.000000     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  705.205    -0.000000     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000000     0.000001 
  708.211    -0.000001    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001 
  711.216    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001 
  714.220     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  717.224     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  720.228     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001 
  723.230     0.000011     0.000002     0.000007     0.000001     0.000006     0.000012     0.000013     0.000001     0.000001     0.000011     0.000005     0.000001     0.000002 
  726.232     0.000004     0.000010     0.000012     0.000002     0.000006     0.000008     0.000010     0.000003     0.000001     0.000012     0.000007     0.000002     0.000003 
  729.234     0.000001     0.000000     0.000001     0.000002     0.000001    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002 
  732.234     0.000024     0.000029     0.000026     0.000023     0.000020     0.000039     0.000039     0.000027     0.000027     0.000016     0.000006     0.000031     0.000033 
  735.235     0.000042     0.000054     0.000055     0.000039     0.000033     0.000054     0.000062     0.000034     0.000033     0.000071     0.000041     0.000029     0.000031 
  738.234     0.000045     0.000054     0.000055     0.000041     0.000036     0.000061     0.000074     0.000029     0.000025     0.000055     0.000030     0.000022     0.000021 
  741.233     0.000012     0.000021     0.000023     0.000002     0.000002     0.000013     0.000022     0.000003     0.000001     0.000057     0.000040     0.000002     0.000003 
  744.231     0.000000     0.000001    -0.000001     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  747.228    -0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000000     0.000001 
  750.225    -0.000000     0.000001    -0.000000     0.000001     0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000001     0.000000    -0.000000     0.000001 
  753.221     0.000001     0.000002     0.000001     0.000001     0.000001     0.000012     0.000008     0.000001     0.000001     0.000013     0.000006     0.000000     0.000001 
  756.272     0.000002     0.000015     0.000014     0.000001     0.000002     0.000104     0.000097     0.000001     0.000001     0.000081     0.000031     0.000001     0.000002 
  759.267     0.000098     0.000154     0.000159     0.000058     0.000059     0.000149     0.000198     0.000049     0.000048     0.000276     0.000190     0.000050     0.000047 
  762.261     0.000040     0.000026     0.000032     0.000058     0.000048     0.000001     0.000001     0.000052     0.000041     0.000012     0.000013     0.000041     0.000032 
  765.254     0.000001     0.000000     0.000001     0.000000     0.000002     0.000002     0.000002     0.000002     0.000002    -0.000000     0.000002     0.000002     0.000001 
  768.247     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001     0.000001 
  771.294    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000001     0.000001     0.000000    -0.000000    -0.000000     0.000001     0.000001     0.000001 
  774.286     0.000000     0.000001     0.000000    -0.000001    -0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001 
  777.277     0.000007     0.000007     0.000007     0.000001     0.000001     0.000014     0.000014     0.000001     0.000001     0.000015     0.000006     0.000001     0.000002 
  780.266     0.000001     0.000001     0.000005     0.000002     0.000002     0.000013     0.000006     0.000001     0.000001     0.000019     0.000012     0.000001     0.000001 
  783.311     0.000001     0.000002     0.000003     0.000002     0.000001    -0.000001     0.000004    -0.000000     0.000001     0.000013     0.000008     0.000001     0.000001 
  786.300     0.000002     0.000001     0.000003     0.000002     0.000002     0.000002     0.000003     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001 
  789.288     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000001 
  792.275     0.000001     0.000001    -0.000001     0.000000     0.000001     0.000000    -0.000000    -0.000001    -0.000000    -0.000001     0.000000     0.000001     0.000001 
  795.316    -0.000000     0.000001    -0.000001     0.000001    -0.000000    -0.000001    -0.000001    -0.000001    -0.000000    -0.000001    -0.000001    -0.000001     0.000001 
  798.302    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  801.287    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  804.327     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  807.310    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001 
  810.348     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  813.331    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000 
  816.312    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000 
  819.348    -0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000000     0.000000 
  822.328    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  825.362    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001 
  828.341     0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  831.374     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  834.351     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  837.382     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001 
  840.357    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001 
  843.387    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001 
  846.361     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001 
  849.389    -0.000000    -0.000000    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001 
  852.362    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000001 
  855.389     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001 
  858.359     0.000001     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  861.385     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000001    -0.000001    -0.000001     0.000000    -0.000000     0.000000     0.000001 
  864.409     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000001 
  867.378     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000001    -0.000000     0.000000    -0.000000     0.000001 
  870.400     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001 
  873.422     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  876.389    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  879.409     0.000000     0.000000    -0.000000     0.000001    -0.000000    -0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001 
  882.428     0.000001     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001 
  885.447     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000 
  888.410     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001 
  891.427     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000 
  894.444    -0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000 
  897.459     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000 
  900.419     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  903.433     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  906.446     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  909.458     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  912.469     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  915.480     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  918.489     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  921.443     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  924.451     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  927.458     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000002     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  930.465     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  933.470     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  936.475     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  939.478     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  942.481     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  945.483     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  948.484     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
  951.484     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  954.538     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  957.537     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
  960.534     0.000000     0.000001     0.000000     0.000000     0.000000     0.000002     0.000000     0.000000     0.000000     0.000002     0.000001     0.000000     0.000000 
  963.531     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000002     0.000001     0.000000     0.000000     0.000002 
  966.526     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001 
  969.521     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  972.515     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  975.563     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  978.555     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  981.546     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  984.537     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  987.580     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000 
  990.569     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  993.556     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  996.543    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  999.583    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1002.568     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
 1005.552     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
 1008.589     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1011.571     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1014.606     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
 1017.587     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
 1020.620     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
 1023.598     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000 
 1026.629     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000 
 1029.606     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000 
 1032.635     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000 
 1035.610     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1038.637     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1041.610     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1044.635     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1047.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1050.629     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1053.652     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1056.620     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1059.640    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1062.660     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1065.678     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
 1068.642     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1071.658    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
 1074.674     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1077.688    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
 1080.702     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1083.660    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1086.672    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
 1089.682    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1092.691    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
 1095.699    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1098.707     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1101.713     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1104.718     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1107.722     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1110.725     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
 1113.727     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000 
 1116.728    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1119.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1122.726     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000 
 1125.724     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1128.720     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1131.770     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000 
 1134.764     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1137.757    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1140.749     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1143.741    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1146.784     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1149.773     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1152.761     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1155.801    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1158.786     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1161.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1164.807     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1167.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1170.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1173.804     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1176.783     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1179.814     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1182.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1185.819    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1188.793     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1191.820    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1194.845     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1197.815     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1200.838     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
