# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     1.490000     2.110000     2.110000     1.320000     1.320000     2.500000     2.500000 
# z_pos      56.000000    56.000000    57.000000    57.000000    55.000000    55.000000    58.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       321          322          323          324          325          326          327          328      
#
# lambda for peak transmission
#          594.0190000  594.0190000  594.0190000  567.0320000  594.0190000  591.0470000  594.0190000  567.0320000 
# peak transmission
#            0.9240920    0.9180230    0.9223820    0.9244660    0.9229450    0.9100840    0.9214610    0.9319420 
# lambda blue with 1/2 of peak transmission
#          501.6601962  501.5236791  501.6986869  501.7930842  501.5942307  501.1958188  501.6682156  501.6216440 
# lambda red  with 1/2 of peak transmission
#          600.6110946  601.0510946  600.5131643  599.7185814  600.7732648  601.2957502  600.5930290  598.6159354 
# half width                              
#           98.9508985   99.5274155   98.8144774   97.9254972   99.1790341  100.0999313   98.9248135   96.9942914 
# central wavelength                      
#          551.1356454  551.2873868  551.1059256  550.7558328  551.1837478  551.2457845  551.1306223  550.1187897 
# central wavelength calculated as SAGEM (mean frequency)
#          546.6942341  546.7953076  546.6765135  546.4029951  546.7222225  546.7015338  546.6915119  545.8433983 
# lambda blue with 80% of peak transmission
#          503.9377300  503.8391371  504.0598750  504.0699517  503.8724040  503.5518038  503.9267565  503.7536440 
# lambda red  with 80% of peak transmission
#          598.0077369  598.4437562  597.9377138  597.3728216  598.1526003  598.7302487  598.0106527  595.9893471 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8912618    0.8805628    0.8879706    0.8943109    0.8861186    0.8733051    0.8820759    0.8986008 
# ATB calculated from points above 50%
#            0.8755433    0.8715267    0.8718460    0.8893051    0.8758001    0.8652705    0.8711207    0.8910835 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.118790 at column =  9, at id = 328 
# maxCWL      = 551.287387 at column =  3, at id = 322 
# difference =    1.1685972 
# minBW       = 96.994291 at column =  9, at id = 328 
# maxBW       = 100.099931 at column =  7, at id = 326 
# difference =    3.1056399 
# minATB80    = 0.873305 at column =  7, at id = 326 
# maxATB80    = 0.898601 at column =  9, at id = 328 
# difference =    0.0252957 
# minBlueEdge = 501.195819 at column =  7, at id = 326 
# maxBlueEdge = 501.793084 at column =  5, at id = 324 
# difference =    0.5972654 
# minRedEdge  = 598.615935 at column =  9, at id = 328 
# maxRedEdge  = 601.295750 at column =  7, at id = 326 
# difference =    2.6798148 
# minABR      = 9.999900 at column =  2, at id = 321 
# maxABR      = 9.999900 at column =  2, at id = 321 
# difference =    0.0000000 
  449.837     0.000002     0.000001     0.000001     0.000001     0.000003     0.000001     0.000001     0.000002 
  452.830     0.000001     0.000001     0.000001     0.000000     0.000002     0.000001     0.000001     0.000001 
  455.878     0.000002     0.000002    -0.000000    -0.000000     0.000002     0.000001     0.000001     0.000002 
  458.870     0.000003     0.000003     0.000001     0.000001     0.000004     0.000002     0.000001     0.000002 
  461.862     0.000003     0.000002     0.000002     0.000001     0.000004     0.000003     0.000003     0.000002 
  464.853     0.000011     0.000003     0.000002     0.000016     0.000004     0.000010     0.000002     0.000002 
  467.901     0.000025     0.000023     0.000021     0.000022     0.000025     0.000026     0.000022     0.000019 
  470.891     0.000021     0.000024     0.000019     0.000016     0.000020     0.000027     0.000019     0.000019 
  473.881     0.000040     0.000041     0.000041     0.000036     0.000042     0.000043     0.000040     0.000036 
  476.871     0.000097     0.000104     0.000094     0.000085     0.000098     0.000121     0.000092     0.000091 
  479.916     0.000147     0.000155     0.000140     0.000127     0.000147     0.000183     0.000138     0.000122 
  482.905     0.000286     0.000298     0.000274     0.000250     0.000286     0.000329     0.000272     0.000243 
  485.894     0.000689     0.000762     0.000680     0.000629     0.000732     0.000951     0.000703     0.000743 
  488.882     0.002505     0.002673     0.002434     0.002273     0.002588     0.003141     0.002465     0.002330 
  491.925     0.006148     0.006392     0.005959     0.005631     0.006277     0.006816     0.005934     0.005692 
  494.913     0.030952     0.032831     0.030529     0.029116     0.031857     0.039119     0.031228     0.035030 
  497.899     0.159345     0.171344     0.156183     0.144720     0.165013     0.199208     0.158960     0.153017 
  500.942     0.374377     0.389825     0.369139     0.354212     0.382202     0.425628     0.371844     0.376845 
  503.928     0.738873     0.744988     0.732390     0.733200     0.745113     0.771663     0.737321     0.768418 
  506.913     0.861770     0.852881     0.857236     0.867209     0.861218     0.842176     0.856406     0.872717 
  509.954     0.857716     0.849562     0.853085     0.860592     0.857486     0.837832     0.852382     0.858910 
  512.939     0.838613     0.830048     0.833436     0.843426     0.838078     0.820185     0.832333     0.849653 
  515.923     0.868363     0.861703     0.864658     0.873942     0.867919     0.855304     0.864546     0.885510 
  518.963     0.889354     0.878991     0.887127     0.899380     0.887138     0.867257     0.885270     0.908549 
  521.946     0.893042     0.886247     0.890953     0.898872     0.891913     0.876043     0.890012     0.904312 
  524.929     0.894295     0.885856     0.891997     0.902411     0.892432     0.872420     0.890369     0.909281 
  527.967     0.887267     0.880390     0.883982     0.892756     0.885717     0.872049     0.882985     0.898804 
  530.949     0.895833     0.887976     0.893308     0.902541     0.894105     0.875881     0.891838     0.909694 
  533.987     0.893144     0.885981     0.889849     0.898681     0.891900     0.877091     0.889266     0.905153 
  536.968     0.885974     0.876587     0.882082     0.893038     0.883818     0.861778     0.880313     0.897925 
  539.948     0.878577     0.872648     0.874773     0.883932     0.878037     0.869597     0.873509     0.890217 
  542.984     0.896146     0.893098     0.893065     0.897531     0.896654     0.890157     0.893834     0.902512 
  545.964     0.910375     0.904632     0.908671     0.915035     0.910048     0.895629     0.908338     0.920134 
  548.999     0.910991     0.904082     0.909959     0.916852     0.910354     0.893888     0.908161     0.923357 
  551.977     0.904812     0.895623     0.902577     0.911462     0.903270     0.880209     0.900076     0.915668 
  555.012     0.896405     0.886689     0.893872     0.903799     0.894496     0.874287     0.890725     0.912668 
  557.989     0.883615     0.871434     0.880159     0.894156     0.881395     0.858284     0.874985     0.899823 
  561.023     0.887472     0.881069     0.883452     0.893754     0.888015     0.880761     0.881822     0.905473 
  563.999     0.914943     0.906136     0.912074     0.921352     0.913858     0.895977     0.910356     0.929171 
  567.032     0.916487     0.906822     0.913986     0.924466     0.915146     0.897399     0.911495     0.931942 
  570.007     0.914729     0.904858     0.911664     0.922087     0.913370     0.890407     0.909338     0.925843 
  573.038     0.878924     0.869211     0.874088     0.883402     0.878063     0.857597     0.870981     0.884145 
  576.013     0.879771     0.875547     0.874751     0.880711     0.880476     0.877264     0.873925     0.886985 
  579.043     0.903335     0.900909     0.899404     0.901835     0.903624     0.900257     0.899475     0.904553 
  582.017     0.914163     0.906528     0.911222     0.918874     0.912271     0.893473     0.909081     0.924282 
  585.046     0.898634     0.888698     0.895042     0.908297     0.895634     0.878902     0.891381     0.912870 
  588.019     0.894316     0.891844     0.891281     0.895047     0.894559     0.889937     0.890484     0.895057 
  591.047     0.918233     0.915435     0.915799     0.916911     0.918358     0.910084     0.916339     0.916904 
  594.019     0.924092     0.918023     0.922382     0.924070     0.922945     0.905242     0.921461     0.905209 
  597.046     0.838207     0.862915     0.831669     0.778213     0.847931     0.875935     0.837203     0.659934 
  600.073     0.526821     0.584641     0.513381     0.420330     0.548199     0.610181     0.523304     0.285953 
  603.043     0.169297     0.203165     0.161230     0.120125     0.180370     0.233356     0.165933     0.073417 
  606.068     0.054565     0.067836     0.051334     0.037132     0.059084     0.080185     0.053323     0.023158 
  609.038     0.015760     0.018994     0.014854     0.011108     0.016861     0.021970     0.015240     0.007058 
  612.062     0.005227     0.006340     0.004923     0.003726     0.005622     0.007401     0.005062     0.002412 
  615.086     0.001727     0.002094     0.001628     0.001225     0.001861     0.002522     0.001681     0.000811 
  618.053     0.000764     0.000922     0.000721     0.000553     0.000821     0.001063     0.000741     0.000378 
  621.076     0.000242     0.000276     0.000229     0.000184     0.000252     0.000292     0.000231     0.000121 
  624.099     0.000087     0.000099     0.000081     0.000063     0.000093     0.000121     0.000081     0.000042 
  627.064     0.000044     0.000054     0.000044     0.000040     0.000049     0.000058     0.000045     0.000026 
  630.086     0.000022     0.000026     0.000022     0.000018     0.000022     0.000026     0.000021     0.000015 
  633.106     0.000019     0.000023     0.000017     0.000014     0.000016     0.000028     0.000018     0.000014 
  636.071     0.000039     0.000046     0.000036     0.000031     0.000041     0.000062     0.000039     0.000033 
  639.090     0.000044     0.000048     0.000037     0.000033     0.000044     0.000055     0.000040     0.000016 
  642.109     0.000003     0.000005     0.000002     0.000002     0.000010     0.000012     0.000003     0.000001 
  645.128     0.000002     0.000004     0.000002     0.000003     0.000002     0.000000     0.000003     0.000001 
  648.090     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000 
  651.107     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000 
  654.123     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  657.139     0.000000     0.000000    -0.000000     0.000001    -0.000001    -0.000000     0.000001     0.000000 
  660.099    -0.000000     0.000000    -0.000000     0.000000    -0.000001    -0.000001     0.000001    -0.000000 