# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     2.110000     2.110000     1.490000     1.320000     2.500000     2.500000     1.320000 
# z_pos      56.000000    57.000000    57.000000    56.000000    55.000000    58.000000    58.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       221          222          223          224          225          226          227          228      
#
# lambda for peak transmission
#          545.9640000  521.9460000  545.9640000  545.9640000  545.9640000  521.9460000  545.9640000  518.9630000 
# peak transmission
#            0.7237880    0.7203631    0.7210361    0.7234615    0.7219251    0.7186977    0.7199493    0.7250360 
# lambda blue with 1/2 of peak transmission
#          501.6553084  501.4526398  501.6514878  501.7067399  501.6061879  501.1530609  501.5929685  501.6588360 
# lambda red  with 1/2 of peak transmission
#          600.7333939  601.0199993  600.5442656  599.5892003  600.9281798  601.1854359  600.5628420  598.8859980 
# half width                              
#           99.0780855   99.5673595   98.8927778   97.8824604   99.3219920  100.0323750   98.9698735   97.2271621 
# central wavelength                      
#          551.1943512  551.2363195  551.0978767  550.6479701  551.2671839  551.1692484  551.0779052  550.2724170 
# central wavelength calculated as SAGEM (mean frequency)
#          546.7419892  546.7402174  546.6613773  546.2981057  546.7934648  546.6304991  546.6343249  545.9776710 
# lambda blue with 80% of peak transmission
#          503.8733931  503.6423563  503.8129071  503.8332370  503.8251783  503.3419446  503.7287946  503.7403283 
# lambda red  with 80% of peak transmission
#          598.0282273  598.3414517  597.8871427  597.1899779  598.2097215  598.5339010  597.9125029  596.1922164 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7017238    0.6997277    0.6984809    0.6989422    0.7002066    0.6983461    0.6970587    0.7028077 
# ATB calculated from points above 50%
#            0.6932796    0.6922461    0.6894987    0.6989422    0.6924297    0.6913445    0.6881591    0.6975137 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.272417 at column =  9, at id = 228 
# maxCWL      = 551.267184 at column =  6, at id = 225 
# difference =    0.9947669 
# minBW       = 97.227162 at column =  9, at id = 228 
# maxBW       = 100.032375 at column =  7, at id = 226 
# difference =    2.8052130 
# minATB80    = 0.697059 at column =  8, at id = 227 
# maxATB80    = 0.702808 at column =  9, at id = 228 
# difference =    0.0057491 
# minBlueEdge = 501.153061 at column =  7, at id = 226 
# maxBlueEdge = 501.706740 at column =  5, at id = 224 
# difference =    0.5536790 
# minRedEdge  = 598.885998 at column =  9, at id = 228 
# maxRedEdge  = 601.185436 at column =  7, at id = 226 
# difference =    2.2994378 
# minABR      = 9.999900 at column =  2, at id = 221 
# maxABR      = 9.999900 at column =  2, at id = 221 
# difference =    0.0000000 
  449.837     0.000001     0.000001     0.000001     0.000000    -0.000001     0.000001     0.000001     0.000001 
  452.830     0.000000    -0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000000     0.000001 
  455.878    -0.000000     0.000001     0.000002     0.000000    -0.000000     0.000001     0.000001     0.000001 
  458.870     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000002     0.000001 
  461.862     0.000002     0.000002     0.000002     0.000001     0.000001     0.000002     0.000001     0.000001 
  464.853     0.000002     0.000015     0.000002     0.000007     0.000006     0.000008     0.000002     0.000002 
  467.901     0.000017     0.000020     0.000019     0.000016     0.000018     0.000020     0.000017     0.000016 
  470.891     0.000015     0.000020     0.000015     0.000013     0.000017     0.000024     0.000018     0.000007 
  473.881     0.000028     0.000034     0.000030     0.000027     0.000031     0.000037     0.000033     0.000031 
  476.871     0.000071     0.000084     0.000073     0.000067     0.000072     0.000095     0.000074     0.000071 
  479.916     0.000111     0.000126     0.000112     0.000102     0.000118     0.000145     0.000114     0.000097 
  482.905     0.000228     0.000243     0.000219     0.000205     0.000233     0.000262     0.000221     0.000200 
  485.894     0.000505     0.000596     0.000521     0.000502     0.000527     0.000742     0.000553     0.000530 
  488.882     0.001944     0.002119     0.001913     0.001837     0.001983     0.002474     0.001958     0.001816 
  491.925     0.004883     0.005074     0.004714     0.004578     0.004965     0.005460     0.004709     0.004505 
  494.913     0.022558     0.025606     0.023095     0.022982     0.022888     0.030896     0.024253     0.024444 
  497.899     0.120426     0.134551     0.120541     0.115080     0.123498     0.156141     0.124587     0.115496 
  500.942     0.292066     0.309785     0.289514     0.283678     0.296137     0.338559     0.294146     0.287610 
  503.928     0.584376     0.604481     0.588347     0.588441     0.587576     0.632686     0.596104     0.599640 
  506.913     0.700494     0.699381     0.698146     0.698966     0.699172     0.696872     0.697322     0.700429 
  509.954     0.699480     0.695431     0.695203     0.695544     0.697899     0.690500     0.693669     0.694795 
  512.939     0.682029     0.676370     0.677035     0.682393     0.680438     0.673316     0.675260     0.683958 
  515.923     0.702889     0.702721     0.700674     0.703589     0.701238     0.703357     0.700828     0.707136 
  518.963     0.720441     0.716469     0.718194     0.722562     0.717378     0.712803     0.716265     0.725036 
  521.946     0.722092     0.720363     0.720295     0.721135     0.720040     0.718698     0.719095     0.721142 
  524.929     0.722109     0.718295     0.719467     0.722235     0.719533     0.714236     0.717621     0.723320 
  527.967     0.714280     0.712106     0.711369     0.712816     0.712091     0.711121     0.710142     0.713471 
  530.949     0.720014     0.715874     0.716841     0.719971     0.718130     0.711606     0.715440     0.721758 
  533.987     0.716063     0.710976     0.711953     0.716393     0.714055     0.707193     0.711044     0.718738 
  536.968     0.710362     0.700977     0.705522     0.712802     0.707941     0.691677     0.702590     0.715725 
  539.948     0.702177     0.696151     0.698058     0.705220     0.700098     0.694944     0.696504     0.708733 
  542.984     0.713401     0.711056     0.710850     0.712370     0.712255     0.711383     0.710596     0.713267 
  545.964     0.723788     0.719707     0.721036     0.723461     0.721925     0.716225     0.719949     0.723524 
  548.999     0.722333     0.718283     0.718672     0.722113     0.720036     0.715312     0.717821     0.721351 
  551.977     0.715924     0.711407     0.711835     0.714946     0.713214     0.705269     0.709892     0.713222 
  555.012     0.706794     0.703652     0.702939     0.706833     0.704118     0.700100     0.700815     0.706037 
  557.989     0.698061     0.692660     0.693110     0.697952     0.694770     0.688850     0.688607     0.697136 
  561.023     0.696521     0.700117     0.694218     0.693710     0.694303     0.706682     0.692572     0.693341 
  563.999     0.716002     0.717085     0.713499     0.710794     0.713879     0.716681     0.711031     0.708593 
  567.032     0.716138     0.715270     0.713420     0.712442     0.713989     0.714914     0.710951     0.711299 
  570.007     0.714136     0.710771     0.710502     0.710975     0.712111     0.703906     0.707293     0.710294 
  573.038     0.685609     0.677997     0.679688     0.683029     0.684161     0.671222     0.675626     0.682712 
  576.013     0.682288     0.680856     0.678766     0.681367     0.681707     0.683466     0.677599     0.683132 
  579.043     0.700359     0.699852     0.697837     0.697203     0.699935     0.701146     0.697202     0.696778 
  582.017     0.708819     0.702696     0.705715     0.709558     0.707035     0.695827     0.702960     0.710472 
  585.046     0.697402     0.689402     0.693628     0.701097     0.693864     0.683424     0.689544     0.703268 
  588.019     0.689930     0.688640     0.687284     0.687604     0.688494     0.688932     0.685854     0.685812 
  591.047     0.705407     0.706269     0.703863     0.700796     0.704576     0.705643     0.703843     0.696864 
  594.019     0.712128     0.708243     0.709920     0.706191     0.710232     0.701140     0.707245     0.695341 
  597.046     0.652931     0.667248     0.643211     0.591794     0.659992     0.677344     0.644282     0.534727 
  600.073     0.425185     0.454713     0.404323     0.317965     0.445524     0.469049     0.405608     0.251424 
  603.043     0.140544     0.158241     0.128257     0.091019     0.151847     0.176170     0.128927     0.066929 
  606.068     0.044206     0.052025     0.040536     0.027897     0.048518     0.059170     0.041303     0.020661 
  609.038     0.012935     0.014562     0.011700     0.008404     0.014069     0.016232     0.011741     0.006351 
  612.062     0.004258     0.004836     0.003882     0.002834     0.004626     0.005377     0.003901     0.002182 
  615.086     0.001382     0.001584     0.001266     0.000924     0.001513     0.001822     0.001285     0.000714 
  618.053     0.000614     0.000701     0.000564     0.000421     0.000668     0.000777     0.000571     0.000334 
  621.076     0.000199     0.000210     0.000181     0.000139     0.000213     0.000215     0.000179     0.000112 
  624.099     0.000068     0.000078     0.000061     0.000045     0.000073     0.000090     0.000064     0.000036 
  627.064     0.000037     0.000039     0.000033     0.000026     0.000039     0.000042     0.000033     0.000021 
  630.086     0.000020     0.000020     0.000017     0.000015     0.000020     0.000019     0.000017     0.000014 
  633.106     0.000014     0.000015     0.000012     0.000012     0.000012     0.000020     0.000012     0.000009 
  636.071     0.000026     0.000032     0.000026     0.000023     0.000025     0.000041     0.000029     0.000021 
  639.090     0.000032     0.000037     0.000027     0.000022     0.000035     0.000038     0.000028     0.000015 
  642.109     0.000005     0.000010     0.000005     0.000001     0.000006     0.000010     0.000002     0.000002 
  645.128     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000001 
  648.090     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000001 
  651.107    -0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
  654.123     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000001     0.000000 
  657.139    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000001 
  660.099    -0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000 