# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 71
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     2.110000     1.490000     1.490000     2.500000     2.500000     1.320000     1.320000 
# z_pos      57.000000    57.000000    56.000000    56.000000    58.000000    58.000000    55.000000    55.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       121          122          123          124          125          126          127          128      
#
# lambda for peak transmission
#          582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000  582.0170000 
# peak transmission
#            0.9144610    0.9222630    0.9316960    0.9211680    0.9045260    0.9219310    0.9387170    0.9223600 
# lambda blue with 1/2 of peak transmission
#          502.3296667  502.6069397  502.8247267  502.5967322  501.9499121  502.5385689  502.7690728  502.5287721 
# lambda red  with 1/2 of peak transmission
#          599.2912019  599.0664767  598.8865121  599.2346092  599.2052226  599.0298204  598.2828209  599.3501600 
# half width                              
#           96.9615352   96.4595371   96.0617854   96.6378769   97.2553105   96.4912515   95.5137480   96.8213879 
# central wavelength                      
#          550.8104343  550.8367082  550.8556194  550.9156707  550.5775673  550.7841946  550.5259468  550.9394661 
# central wavelength calculated as SAGEM (mean frequency)
#          546.5432950  546.6138405  546.6676497  546.6777810  546.2827159  546.5581467  546.3831466  546.6856497 
# lambda blue with 80% of peak transmission
#          506.6122785  507.9558859  508.9002621  506.8235950  506.0356887  508.0080352  509.1578881  506.6530732 
# lambda red  with 80% of peak transmission
#          596.8357618  596.5299563  596.3459232  596.8617393  596.5349182  596.4117313  595.6492426  597.0478222 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.8590056    0.8651518    0.8764353    0.8672752    0.8504688    0.8609276    0.8832188    0.8666583 
# ATB calculated from points above 50%
#            0.8485096    0.8487237    0.8579365    0.8555928    0.8406127    0.8448240    0.8619650    0.8597149 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 550.525947 at column =  8, at id = 127 
# maxCWL      = 550.939466 at column =  9, at id = 128 
# difference =    0.4135192 
# minBW       = 95.513748 at column =  8, at id = 127 
# maxBW       = 97.255311 at column =  6, at id = 125 
# difference =    1.7415625 
# minATB80    = 0.850469 at column =  6, at id = 125 
# maxATB80    = 0.883219 at column =  8, at id = 127 
# difference =    0.0327499 
# minBlueEdge = 501.949912 at column =  6, at id = 125 
# maxBlueEdge = 502.824727 at column =  4, at id = 123 
# difference =    0.8748146 
# minRedEdge  = 598.282821 at column =  8, at id = 127 
# maxRedEdge  = 599.350160 at column =  9, at id = 128 
# difference =    1.0673392 
# minABR      = 9.999900 at column =  2, at id = 121 
# maxABR      = 9.999900 at column =  2, at id = 121 
# difference =    0.0000000 
  449.837     0.000001     0.000000    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000002 
  452.830     0.000000     0.000001    -0.000002     0.000001     0.000001     0.000001     0.000001     0.000002 
  455.878    -0.000001     0.000001    -0.000001     0.000001     0.000000     0.000002     0.000001     0.000000 
  458.870     0.000001     0.000001     0.000000     0.000001     0.000001     0.000002     0.000002     0.000001 
  461.862     0.000002     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  464.853     0.000001     0.000001    -0.000000     0.000001     0.000001     0.000002     0.000001     0.000002 
  467.901     0.000009     0.000002     0.000001     0.000002     0.000008     0.000002     0.000002     0.000002 
  470.891     0.000020     0.000020     0.000021     0.000023     0.000027     0.000025     0.000021     0.000020 
  473.881     0.000035     0.000032     0.000031     0.000037     0.000044     0.000036     0.000027     0.000039 
  476.871     0.000068     0.000062     0.000058     0.000063     0.000083     0.000065     0.000062     0.000063 
  479.916     0.000153     0.000137     0.000124     0.000142     0.000173     0.000138     0.000126     0.000145 
  482.905     0.000480     0.000428     0.000390     0.000438     0.000541     0.000433     0.000385     0.000456 
  485.894     0.000670     0.000587     0.000524     0.000599     0.000782     0.000602     0.000507     0.000625 
  488.882     0.001987     0.001750     0.001584     0.001779     0.002290     0.001790     0.001551     0.001848 
  491.925     0.005629     0.004840     0.004301     0.004839     0.006980     0.005057     0.004486     0.004998 
  494.913     0.019575     0.016762     0.014801     0.016888     0.023961     0.017482     0.014696     0.017588 
  497.899     0.075584     0.064926     0.057237     0.064927     0.093693     0.067951     0.058982     0.067687 
  500.942     0.279058     0.244657     0.217748     0.245128     0.328999     0.254436     0.220094     0.254779 
  503.928     0.662452     0.632895     0.611234     0.633923     0.694176     0.640700     0.627469     0.643186 
  506.913     0.739312     0.730515     0.727857     0.740115     0.735877     0.728791     0.719227     0.746921 
  509.954     0.755989     0.751788     0.754636     0.757522     0.755022     0.753101     0.762232     0.763108 
  512.939     0.770028     0.769830     0.771325     0.772199     0.766358     0.770978     0.777895     0.777120 
  515.923     0.795830     0.799339     0.806556     0.802524     0.784212     0.796198     0.808041     0.805454 
  518.963     0.760999     0.759261     0.763274     0.762639     0.763945     0.759366     0.772476     0.766808 
  521.946     0.842983     0.845582     0.849787     0.844051     0.839585     0.845528     0.859563     0.847609 
  524.929     0.847345     0.850870     0.859548     0.852318     0.839716     0.846170     0.869596     0.854525 
  527.967     0.868522     0.872240     0.888390     0.880029     0.856702     0.865672     0.896546     0.882549 
  530.949     0.858037     0.862354     0.875204     0.868240     0.848827     0.860427     0.883862     0.871829 
  533.987     0.867920     0.872765     0.880572     0.872646     0.859395     0.874818     0.885172     0.876258 
  536.968     0.876139     0.881975     0.889332     0.879686     0.867283     0.881363     0.900457     0.881725 
  539.948     0.873301     0.875864     0.887732     0.881404     0.859089     0.864024     0.889126     0.883715 
  542.984     0.859956     0.851263     0.872109     0.870884     0.849879     0.827482     0.879779     0.874405 
  545.964     0.850445     0.835793     0.863622     0.869769     0.835954     0.808623     0.866440     0.876870 
  548.999     0.854840     0.842915     0.868288     0.877162     0.840902     0.823988     0.873140     0.886742 
  551.977     0.852340     0.849520     0.867354     0.872023     0.838663     0.840307     0.870387     0.881262 
  555.012     0.868927     0.872697     0.885917     0.883631     0.858127     0.868014     0.891877     0.889375 
  557.989     0.859422     0.861639     0.871593     0.869699     0.851682     0.858766     0.873563     0.875396 
  561.023     0.860391     0.863084     0.874852     0.867627     0.857335     0.860477     0.886464     0.871708 
  563.999     0.899597     0.902559     0.911559     0.904942     0.895120     0.903190     0.923396     0.907826 
  567.032     0.908175     0.912399     0.920058     0.914093     0.899596     0.910920     0.923996     0.916850 
  570.007     0.884071     0.890514     0.902658     0.893412     0.873600     0.885984     0.911713     0.894894 
  573.038     0.900806     0.903923     0.917853     0.909252     0.892892     0.900909     0.926061     0.911471 
  576.013     0.890983     0.894895     0.905735     0.900650     0.883056     0.895577     0.912278     0.903718 
  579.043     0.905783     0.912572     0.921017     0.911925     0.899620     0.916051     0.932095     0.914683 
  582.017     0.914461     0.922263     0.931696     0.921168     0.904526     0.921931     0.938717     0.922360 
  585.046     0.913147     0.917122     0.929045     0.920935     0.904036     0.917054     0.937164     0.922273 
  588.019     0.906836     0.914887     0.926389     0.917898     0.894462     0.916551     0.935256     0.919862 
  591.047     0.893148     0.905901     0.916788     0.903518     0.878401     0.905371     0.926357     0.904344 
  594.019     0.891109     0.895235     0.905278     0.896927     0.880650     0.889735     0.900999     0.898250 
  597.046     0.719661     0.705457     0.697243     0.726564     0.691722     0.697202     0.622435     0.738107 
  600.073     0.365850     0.339418     0.316679     0.358695     0.356026     0.336742     0.247795     0.374305 
  603.043     0.104574     0.092952     0.081922     0.100693     0.099781     0.092243     0.056340     0.107673 
  606.068     0.026888     0.023533     0.021070     0.025239     0.027424     0.023467     0.016123     0.026838 
  609.038     0.008323     0.007319     0.006468     0.007934     0.008161     0.007300     0.004622     0.008481 
  612.062     0.002688     0.002327     0.002071     0.002490     0.002816     0.002344     0.001639     0.002659 
  615.086     0.001051     0.000932     0.000838     0.001004     0.001041     0.000930     0.000634     0.001075 
  618.053     0.000391     0.000341     0.000304     0.000364     0.000410     0.000343     0.000242     0.000387 
  621.076     0.000211     0.000186     0.000165     0.000197     0.000221     0.000187     0.000134     0.000209 
  624.099     0.000099     0.000087     0.000075     0.000093     0.000096     0.000079     0.000062     0.000097 
  627.064     0.000063     0.000053     0.000047     0.000057     0.000065     0.000053     0.000040     0.000058 
  630.086     0.000039     0.000037     0.000031     0.000041     0.000046     0.000035     0.000025     0.000041 
  633.106     0.000020     0.000018     0.000018     0.000017     0.000019     0.000018     0.000011     0.000018 
  636.071     0.000011     0.000010     0.000011     0.000011     0.000013     0.000006     0.000001     0.000011 
  639.090     0.000013     0.000013     0.000010     0.000011     0.000015     0.000006     0.000003     0.000013 
  642.109     0.000007     0.000006    -0.000000     0.000004     0.000002     0.000006     0.000001     0.000011 
  645.128     0.000002     0.000003     0.000001    -0.000001     0.000003     0.000001     0.000001    -0.000001 
  648.090     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000002 
  651.107     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002     0.000001     0.000002 
  654.123     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  657.139     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001 
  660.099     0.000001     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000     0.000001 