# number of points on sci filter + aux + bad z = 13
# number of points on sci filter               = 13
# number of positions in lambda                = 371
# noof scans  1            1            1            1            1            1            1            1            1            1            1            1            1          
# x_pos       0.000000    17.670000   -17.670000   -17.670000    17.670000    35.340000   -35.340000   -35.340000    35.340000    53.010000   -53.010000   -53.010000    53.010000 
# y_pos       0.000000    17.670000    17.670000   -17.670000   -17.670000    35.340000    35.340000   -35.340000   -35.340000    53.010000    53.010000   -53.010000   -53.010000 
# angle       1.780000     2.230000     1.840000     1.320000     1.840000     2.690000     2.000000     0.870000     2.000000     3.140000     2.230000     0.410000     2.230000 
# z_pos      44.000000    47.000000    45.000000    43.000000    45.000000    48.000000    46.000000    42.000000    46.000000    49.000000    47.000000    41.000000    47.000000 
# r_pos       0.000000    24.990000    24.990000    24.990000    24.990000    49.980000    49.980000    49.980000    49.980000    74.970000    74.970000    74.970000    74.970000 
# phi         0.000000     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602     0.785398     2.356194     3.926806     5.497602 
# gnupl col      2            3            4            5            6            7            8            9           10           11           12           13           14      
# pos_id       102          103          104          105          106          107          108          109          110          111          112          113          114      
#
# lambda for peak transmission
#          675.6700000  675.6700000  675.6700000  675.6700000  675.6700000  675.1680000  675.1680000  676.1720000  676.1720000  675.1680000  675.1680000  676.1720000  676.1720000 
# peak transmission
#            0.5879144    0.5974623    0.5833236    0.5943661    0.5889102    0.6116310    0.5853809    0.6050350    0.5873826    0.6039820    0.5977771    0.6133082    0.5951350 
# lambda blue with 1/2 of peak transmission
#          673.1152459  672.9479397  672.9378985  673.3819929  673.3729013  672.8390470  672.7776987  673.6094563  673.7203871  672.4469773  672.3100320  673.7698846  674.0813538 
# lambda red  with 1/2 of peak transmission
#          684.7069878  684.4296015  684.5299869  684.9625783  684.9002499  684.1256089  684.4033394  685.2227777  685.2103950  683.5562105  683.8506877  685.5303184  685.6115345 
# half width                              
#           11.5917419   11.4816618   11.5920884   11.5805854   11.5273486   11.2865619   11.6256407   11.6133214   11.4900079   11.1092332   11.5406557   11.7604338   11.5301807 
# central wavelength                      
#          678.9111169  678.6887706  678.7339427  679.1722856  679.1365756  678.4823279  678.5905191  679.4161170  679.4653910  678.0015939  678.0803599  679.6501015  679.8464441 
# central wavelength calculated as SAGEM (mean frequency)
#          678.8616375  678.6402106  678.6844474  679.1229203  679.0876606  678.4353899  678.5407263  679.3664901  679.4168160  677.9560869  678.0312555  679.5992269  679.7975562 
# lambda blue with 80% of peak transmission
#          674.0776274  673.9414533  673.9354546  674.3453370  674.3366009  673.8637948  673.7622863  674.5439647  674.6297983  673.5207504  673.3126517  674.7051347  675.0112376 
# lambda red  with 80% of peak transmission
#          683.5499194  683.1724038  683.4210177  683.8025417  683.7233545  682.3735707  683.2660087  683.9404878  683.9624700  679.1774078  682.6439733  684.1614092  684.1912553 
# lambda blue with 0.0001 of peak transmission
#          658.8950986  657.6982573  657.3201573  658.1543784  659.0136635  657.1824730  658.8760269  658.9207589  659.7725661  659.2021354  658.2714207  658.2667376  658.8696111 
# lambda red  with 0.0001 of peak transmission
#          704.2597358  696.1440659  704.0894715  697.1732911  704.3105739  702.8571784  696.1797566  698.1666473  704.4236521  698.5592079  703.3442499  704.5584142  704.5819690 
# ATB calculated from points above 80%
#            0.5560382    0.5482293    0.5538030    0.5712950    0.5542229    0.5501465    0.5482522    0.5777001    0.5488819    0.5499238    0.5436471    0.5793107    0.5451675 
# ATB calculated from points above 50%
#            0.5167359    0.5194660    0.5247543    0.5401812    0.5246669    0.5212311    0.5211978    0.5359996    0.5191839    0.4947060    0.5172032    0.5509388    0.5161248 
# ABR calculated from points below and above 0.0001
#            0.0000630    0.0002418    0.0000468    0.0001548    0.0000294    0.0002268    0.0001816    0.0002440   -0.0001602    0.0004034    0.0004142    0.0003650    0.0000308 
# minCWL      = 678.001594 at column = 11, at id = 111 
# maxCWL      = 679.846444 at column = 14, at id = 114 
# difference =    1.8448503 
# minBW       = 11.109233 at column = 11, at id = 111 
# maxBW       = 11.760434 at column = 13, at id = 113 
# difference =    0.6512006 
# minATB80    = 0.543647 at column = 12, at id = 112 
# maxATB80    = 0.579311 at column = 13, at id = 113 
# difference =    0.0356636 
# minBlueEdge = 672.310032 at column = 12, at id = 112 
# maxBlueEdge = 674.081354 at column = 14, at id = 114 
# difference =    1.7713218 
# minRedEdge  = 683.556210 at column = 11, at id = 111 
# maxRedEdge  = 685.611535 at column = 14, at id = 114 
# difference =    2.0553240 
# minABR      = -0.000160 at column = 10, at id = 110 
# maxABR      = 0.000414 at column = 12, at id = 112 
# difference =    0.0005745 
  299.645    -0.000107    -0.000024    -0.000270    -0.000434    -0.000171     0.000202     0.000024    -0.000045    -0.000385     0.000389     0.000115     0.000398     0.000045 
  302.654    -0.000083    -0.000061    -0.000039     0.000064    -0.000121    -0.000015    -0.000175    -0.000012    -0.000161    -0.000022     0.000106     0.000036    -0.000116 
  305.662    -0.000025     0.000025    -0.000002     0.000024    -0.000015     0.000020    -0.000073     0.000022    -0.000046    -0.000012     0.000036     0.000019    -0.000099 
  308.671    -0.000011    -0.000002    -0.000021     0.000010     0.000016    -0.000052     0.000002    -0.000005    -0.000012    -0.000022     0.000026    -0.000007    -0.000049 
  311.679    -0.000009    -0.000007     0.000020     0.000034    -0.000024    -0.000035     0.000023     0.000012    -0.000009     0.000010     0.000015     0.000010    -0.000023 
  314.687    -0.000003    -0.000006    -0.000021     0.000006    -0.000011    -0.000016    -0.000015    -0.000007     0.000001    -0.000001     0.000024     0.000008    -0.000006 
  317.694     0.000001     0.000006    -0.000015     0.000002     0.000005     0.000004    -0.000026     0.000012     0.000004    -0.000008     0.000009     0.000003    -0.000022 
  320.702    -0.000022    -0.000009     0.000002     0.000001     0.000001     0.000012    -0.000005    -0.000002    -0.000008    -0.000003    -0.000006     0.000006    -0.000004 
  323.709    -0.000014    -0.000008    -0.000008    -0.000004    -0.000001     0.000001    -0.000006     0.000003    -0.000014    -0.000001     0.000009     0.000005    -0.000008 
  326.716     0.000011     0.000004     0.000010     0.000001    -0.000001     0.000005    -0.000010    -0.000004    -0.000017     0.000004     0.000017    -0.000000    -0.000007 
  329.665     0.000001     0.000005    -0.000002    -0.000007    -0.000010    -0.000003     0.000001     0.000002    -0.000005    -0.000008     0.000018    -0.000005    -0.000010 
  332.672    -0.000007    -0.000001    -0.000000     0.000001    -0.000007    -0.000004     0.000001     0.000001    -0.000010    -0.000002     0.000016    -0.000007    -0.000001 
  335.678    -0.000014     0.000002    -0.000002    -0.000006     0.000008    -0.000007    -0.000008    -0.000006    -0.000006     0.000006     0.000001    -0.000006     0.000004 
  338.683     0.000001     0.000003     0.000009    -0.000004     0.000003     0.000002    -0.000007     0.000006    -0.000005     0.000006     0.000005    -0.000001    -0.000006 
  341.689    -0.000003     0.000006     0.000001     0.000003     0.000006     0.000003     0.000001     0.000003    -0.000002     0.000006     0.000003    -0.000003    -0.000008 
  344.694    -0.000004     0.000003    -0.000002     0.000001     0.000004     0.000005     0.000001    -0.000002    -0.000002     0.000007     0.000007    -0.000005    -0.000001 
  347.699    -0.000003     0.000001    -0.000001    -0.000001     0.000004    -0.000002     0.000002     0.000000    -0.000001     0.000006     0.000003    -0.000001    -0.000008 
  350.703     0.000001    -0.000000     0.000003     0.000001     0.000003     0.000001    -0.000002    -0.000002     0.000000     0.000003     0.000004    -0.000002    -0.000000 
  353.707     0.000000     0.000003    -0.000001     0.000002     0.000000     0.000002    -0.000003    -0.000001    -0.000003     0.000007     0.000007    -0.000003    -0.000000 
  356.711    -0.000001    -0.000002     0.000003    -0.000001    -0.000003     0.000000     0.000001    -0.000005    -0.000008     0.000005     0.000001     0.000002     0.000002 
  359.715    -0.000001    -0.000004     0.000001    -0.000001     0.000001    -0.000001    -0.000001    -0.000003    -0.000002     0.000007     0.000003    -0.000005    -0.000001 
  362.718     0.000001    -0.000001     0.000003     0.000002    -0.000001    -0.000001    -0.000002     0.000000    -0.000001     0.000002     0.000004    -0.000004    -0.000007 
  365.721    -0.000001     0.000000     0.000001    -0.000001     0.000001    -0.000002     0.000002     0.000000    -0.000005     0.000004     0.000003    -0.000001    -0.000001 
  368.724    -0.000002    -0.000002     0.000001    -0.000001    -0.000000    -0.000002     0.000003    -0.000004     0.000001     0.000001     0.000002    -0.000005     0.000001 
  371.726    -0.000001     0.000001     0.000001     0.000003    -0.000003     0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000001    -0.000005    -0.000000 
  374.728    -0.000001     0.000001    -0.000001     0.000003    -0.000000    -0.000001     0.000001    -0.000004     0.000000     0.000000     0.000003    -0.000001    -0.000001 
  377.730    -0.000001     0.000000    -0.000000    -0.000001     0.000001    -0.000001     0.000000    -0.000001    -0.000001     0.000001     0.000003    -0.000000    -0.000001 
  380.788    -0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000001     0.000001     0.000003    -0.000001    -0.000003 
  383.789    -0.000001     0.000002     0.000001    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000002    -0.000000     0.000001    -0.000001 
  386.789    -0.000002     0.000001     0.000001    -0.000001     0.000001    -0.000001     0.000001     0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000001 
  389.790    -0.000001    -0.000001     0.000002    -0.000000     0.000001     0.000000    -0.000000     0.000002    -0.000002     0.000001     0.000002    -0.000001    -0.000001 
  392.790     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000002    -0.000002    -0.000002     0.000001    -0.000000     0.000001 
  395.790    -0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000002    -0.000002     0.000001 
  398.789     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000002    -0.000002     0.000002     0.000001    -0.000002    -0.000000 
  401.788    -0.000000    -0.000000     0.000001     0.000002     0.000002    -0.000001     0.000000     0.000002    -0.000002    -0.000000     0.000001    -0.000001    -0.000001 
  404.787    -0.000001    -0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000002    -0.000002     0.000002     0.000002    -0.000002    -0.000001 
  407.785    -0.000001    -0.000000    -0.000001     0.000002     0.000000    -0.000001     0.000001     0.000002    -0.000000     0.000001     0.000001    -0.000000    -0.000001 
  410.783    -0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000002    -0.000000     0.000002     0.000001     0.000000    -0.000001 
  413.781     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000001     0.000002    -0.000000     0.000002     0.000002     0.000002     0.000001 
  416.834     0.000000     0.000000     0.000001    -0.000001    -0.000001     0.000000    -0.000000     0.000001    -0.000000     0.000002     0.000002     0.000001     0.000000 
  419.831     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001 
  422.828     0.000000    -0.000000     0.000001     0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000000     0.000001    -0.000000    -0.000000 
  425.824    -0.000000     0.000001     0.000002    -0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000001 
  428.820    -0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000 
  431.815     0.000000     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000 
  434.810     0.000000     0.000000     0.000000     0.000000     0.000002     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000001     0.000002     0.000001 
  437.862     0.000001    -0.000001    -0.000000    -0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000 
  440.856     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000002    -0.000000     0.000000     0.000001     0.000001     0.000002     0.000001     0.000000 
  443.850     0.000001     0.000001     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000000 
  446.844     0.000000     0.000001     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  449.837     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000 
  452.830    -0.000001     0.000001     0.000001    -0.000000    -0.000000     0.000000    -0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000001 
  455.878    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000001     0.000000     0.000000     0.000000 
  458.870     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000001     0.000001    -0.000001     0.000000    -0.000000     0.000001     0.000001     0.000000 
  461.862     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000 
  464.853    -0.000000    -0.000001    -0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  467.901     0.000000     0.000001     0.000001    -0.000000     0.000000    -0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000001    -0.000000     0.000001 
  470.891     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  473.881     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  476.871     0.000001     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000000     0.000001    -0.000000     0.000000 
  479.916    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001 
  482.905     0.000000     0.000001     0.000000    -0.000001     0.000000    -0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000    -0.000000 
  485.894     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000 
  488.882     0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000 
  491.925    -0.000000     0.000001     0.000001    -0.000001    -0.000001    -0.000000     0.000001     0.000001    -0.000000     0.000000     0.000001    -0.000000    -0.000000 
  494.913    -0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000001     0.000000    -0.000000 
  497.899     0.000000    -0.000000     0.000001    -0.000001    -0.000001     0.000001     0.000000     0.000001    -0.000001     0.000000     0.000002     0.000000    -0.000000 
  500.942     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000001    -0.000001 
  503.928     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000001 
  506.913     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000 
  509.954    -0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000 
  512.939    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000002     0.000001     0.000000     0.000000     0.000001     0.000001     0.000000 
  515.923     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000001    -0.000000     0.000000 
  518.963     0.000000    -0.000000     0.000001     0.000001     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001 
  521.946    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000 
  524.929     0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000     0.000001 
  527.967     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000001     0.000000    -0.000000 
  530.949     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000001 
  533.987    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000 
  536.968     0.000000    -0.000000     0.000001    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001 
  539.948     0.000000     0.000000     0.000001     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000 
  542.984    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000000     0.000000 
  545.964     0.000000     0.000000     0.000001    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000 
  548.999     0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000001    -0.000000     0.000000 
  551.977    -0.000000     0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000     0.000000 
  555.012    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000000     0.000000 
  557.989     0.000000     0.000001     0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000001     0.000001     0.000001     0.000001     0.000000    -0.000000 
  561.023     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001    -0.000000     0.000001 
  563.999     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  567.032     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  570.007     0.000001     0.000001    -0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000001    -0.000001     0.000000     0.000001     0.000000     0.000001 
  573.038     0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000 
  576.013     0.000001     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000 
  579.043     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  582.017     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000000    -0.000000     0.000000 
  585.046    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000000 
  588.019    -0.000000     0.000000     0.000004     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 
  591.047     0.000004     0.000005     0.000002     0.000001     0.000001     0.000005     0.000004     0.000007     0.000001     0.000002     0.000001     0.000001     0.000002 
  594.019     0.000011     0.000011     0.000008     0.000012     0.000010     0.000009     0.000009     0.000013     0.000013     0.000010     0.000011     0.000015     0.000011 
  597.046     0.000005     0.000002     0.000002     0.000004     0.000005     0.000002     0.000002     0.000009     0.000003     0.000001     0.000001     0.000012     0.000006 
  600.073     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000002     0.000005     0.000002 
  603.043     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001 
  606.068     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000 
  609.038     0.000000     0.000001     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000 
  612.062     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001    -0.000000 
  615.086     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000002     0.000001    -0.000000 
  618.053     0.000001     0.000002     0.000002     0.000001     0.000001     0.000002     0.000010     0.000005     0.000001     0.000002     0.000011     0.000001     0.000001 
  621.076     0.000011     0.000011     0.000010     0.000008     0.000008     0.000013     0.000009     0.000011     0.000010     0.000011     0.000013     0.000010     0.000011 
  624.099     0.000013     0.000011     0.000011     0.000011     0.000011     0.000010     0.000011     0.000010     0.000009     0.000009     0.000012     0.000013     0.000011 
  627.064     0.000011     0.000010     0.000009     0.000011     0.000010     0.000009     0.000008     0.000010     0.000009     0.000008     0.000009     0.000012     0.000011 
  630.086     0.000010     0.000009     0.000008     0.000010     0.000008     0.000010     0.000011     0.000009     0.000008     0.000008     0.000009     0.000011     0.000008 
  633.106     0.000011     0.000010     0.000011     0.000010     0.000008     0.000005     0.000011     0.000010     0.000009     0.000009     0.000011     0.000011     0.000010 
  636.071     0.000012     0.000010     0.000010     0.000011     0.000009     0.000011     0.000005     0.000012     0.000009     0.000009     0.000011     0.000011     0.000011 
  639.090     0.000014     0.000010     0.000010     0.000012     0.000010     0.000012     0.000011     0.000012     0.000012     0.000011     0.000011     0.000013     0.000010 
  642.109     0.000013     0.000014     0.000015     0.000013     0.000014     0.000011     0.000012     0.000013     0.000013     0.000014     0.000015     0.000014     0.000013 
  645.128     0.000022     0.000019     0.000018     0.000020     0.000019     0.000015     0.000017     0.000018     0.000019     0.000018     0.000021     0.000016     0.000016 
  648.090     0.000030     0.000025     0.000028     0.000029     0.000025     0.000024     0.000027     0.000027     0.000024     0.000031     0.000030     0.000025     0.000025 
  651.107     0.000047     0.000044     0.000046     0.000046     0.000042     0.000044     0.000047     0.000044     0.000039     0.000048     0.000053     0.000047     0.000039 
  654.123     0.000080     0.000078     0.000078     0.000075     0.000072     0.000080     0.000084     0.000077     0.000066     0.000087     0.000093     0.000078     0.000065 
  657.139     0.000044     0.000030     0.000044     0.000011    -0.000004     0.000056     0.000013     0.000028     0.000022     0.000004     0.000032     0.000046     0.000034 
  657.642     0.000052     0.000057     0.000083     0.000085     0.000088     0.000115     0.000056     0.000022     0.000044     0.000100     0.000094     0.000041     0.000034 
  658.145     0.000048     0.000083     0.000060     0.000059     0.000021     0.000083     0.000074     0.000064     0.000021     0.000098     0.000049     0.000055     0.000076 
  658.647     0.000049     0.000085     0.000085     0.000084     0.000045     0.000084     0.000055     0.000046     0.000034     0.000087     0.000093     0.000083     0.000024 
  659.150     0.000069     0.000074     0.000099     0.000079     0.000064     0.000111     0.000063     0.000073     0.000021     0.000056     0.000133     0.000089     0.000104 
  659.653     0.000106     0.000077     0.000089     0.000113     0.000097     0.000149     0.000060     0.000484     0.000050     0.000099     0.000169     0.000109     0.000127 
  660.099     0.000108     0.000070     0.000102     0.000118     0.000079     0.000127     0.000095     0.000080     0.000082     0.000127     0.000163     0.000075     0.000110 
  660.602     0.000146     0.000134     0.000125     0.000129     0.000068     0.000178     0.000107     0.000106     0.000068     0.000129     0.000160     0.000119     0.000072 
  661.104     0.000165     0.000176     0.000155     0.000146     0.000116     0.000196     0.000167     0.000149     0.000099     0.000165     0.000190     0.000163     0.000109 
  661.607     0.000154     0.000171     0.000514     0.000176     0.000128     0.000232     0.000193     0.000138     0.000429     0.000221     0.000239     0.000207     0.000072 
  662.109     0.000192     0.000232     0.000443     0.000213     0.000508     0.000245     0.000278     0.000207     0.000094     0.000872     0.000616     0.000541     0.000128 
  662.612     0.000225     0.000223     0.000797     0.000234     0.000676     0.000929     0.000627     0.000275     0.000103     0.000933     0.000995     0.000748     0.000104 
  663.114     0.000896     0.000689     0.001042     0.000902     0.000681     0.000976     0.000825     0.000926     0.000821     0.001209     0.001236     0.000915     0.000202 
  663.617     0.000989     0.001181     0.001112     0.001027     0.000978     0.001271     0.001220     0.001122     0.000893     0.001515     0.001562     0.000945     0.000263 
  664.119     0.001159     0.001351     0.001420     0.001271     0.001202     0.001535     0.001346     0.001300     0.001053     0.001881     0.001994     0.001184     0.001042 
  664.621     0.001414     0.001556     0.001846     0.001447     0.001387     0.001846     0.001610     0.001515     0.001158     0.002271     0.002331     0.001389     0.001070 
  665.124     0.001932     0.001944     0.002056     0.001774     0.001790     0.002294     0.002094     0.001768     0.001571     0.002877     0.003009     0.001702     0.001294 
  665.626     0.002350     0.002615     0.002640     0.002208     0.002229     0.003023     0.002579     0.002316     0.001899     0.003638     0.003938     0.002114     0.001629 
  666.129     0.003054     0.003323     0.003399     0.002914     0.002680     0.003643     0.003429     0.002696     0.002420     0.004601     0.005007     0.002642     0.002073 
  666.631     0.003858     0.004317     0.004356     0.003557     0.003543     0.004678     0.004282     0.003276     0.003124     0.006042     0.006627     0.003401     0.002559 
  667.133     0.005009     0.005685     0.005516     0.004686     0.004417     0.006264     0.006168     0.004474     0.003754     0.008170     0.008620     0.004197     0.003224 
  667.635     0.006480     0.007178     0.007207     0.005886     0.005602     0.008268     0.008048     0.005595     0.004894     0.010674     0.011157     0.005338     0.004149 
  668.138     0.008664     0.009526     0.009707     0.007734     0.007646     0.010998     0.010799     0.007351     0.006486     0.014461     0.015350     0.006913     0.005222 
  668.640     0.011622     0.012942     0.012872     0.010161     0.010055     0.014532     0.014556     0.009645     0.008390     0.019860     0.021224     0.009183     0.007013 
  669.142     0.016422     0.018243     0.018244     0.014335     0.014127     0.021014     0.020124     0.013030     0.011593     0.028939     0.030481     0.012304     0.009264 
  669.645     0.022700     0.025629     0.025510     0.019531     0.019221     0.029313     0.028499     0.017646     0.015615     0.041182     0.043349     0.016502     0.012433 
  670.147     0.031745     0.036542     0.035963     0.027218     0.026898     0.041646     0.041064     0.024224     0.021463     0.058449     0.062407     0.022714     0.017080 
  670.649     0.045651     0.052990     0.051908     0.038539     0.038279     0.060558     0.059401     0.034006     0.030093     0.085947     0.091215     0.031575     0.023762 
  671.151     0.067191     0.077808     0.076635     0.056133     0.055261     0.089313     0.087451     0.048647     0.043318     0.125250     0.133461     0.044954     0.033325 
  671.653     0.098004     0.114136     0.112545     0.081722     0.081202     0.130694     0.128792     0.070894     0.063019     0.178989     0.191809     0.064942     0.047722 
  672.155     0.145637     0.168226     0.165144     0.120822     0.120351     0.190470     0.188973     0.104526     0.093265     0.251345     0.270177     0.094914     0.070597 
  672.658     0.213624     0.243748     0.239467     0.178437     0.177371     0.270612     0.269492     0.154767     0.138488     0.338595     0.363330     0.139684     0.104752 
  673.160     0.301820     0.338946     0.333079     0.258128     0.257807     0.368223     0.366782     0.227438     0.205356     0.431059     0.457328     0.205810     0.156670 
  673.662     0.393296     0.428799     0.419815     0.346444     0.344219     0.455742     0.453125     0.311295     0.282166     0.503596     0.526038     0.284972     0.221884 
  674.164     0.486341     0.517128     0.505810     0.446088     0.442905     0.539236     0.529111     0.412678     0.381261     0.562331     0.574258     0.385860     0.312483 
  674.666     0.549638     0.573539     0.558439     0.527491     0.524991     0.591586     0.571973     0.506944     0.476796     0.594162     0.594144     0.484660     0.412879 
  675.168     0.584006     0.596711     0.582151     0.575627     0.572519     0.611631     0.585381     0.570584     0.546566     0.603982     0.597777     0.561457     0.504819 
  675.670     0.587914     0.597462     0.583324     0.594366     0.588910     0.611128     0.582222     0.602413     0.584692     0.598078     0.587971     0.602732     0.572010 
  676.172     0.580328     0.585268     0.573436     0.592079     0.583502     0.599578     0.572015     0.605035     0.587383     0.584074     0.576124     0.613308     0.595135 
  676.674     0.569791     0.572658     0.563297     0.583877     0.571272     0.584499     0.562456     0.600016     0.578067     0.567750     0.565106     0.609710     0.591746 
  677.120     0.560573     0.562735     0.558272     0.577209     0.563260     0.573666     0.555944     0.593802     0.567999     0.551920     0.555392     0.603380     0.580794 
  677.622     0.556488     0.554396     0.552983     0.573213     0.555990     0.560254     0.550734     0.589356     0.556564     0.533954     0.545250     0.597084     0.566885 
  678.124     0.553886     0.548972     0.551633     0.572745     0.552285     0.549524     0.546400     0.586198     0.551482     0.516077     0.536678     0.592462     0.556632 
  678.626     0.553267     0.543944     0.551008     0.575030     0.552264     0.538510     0.542155     0.587592     0.549232     0.499197     0.528410     0.590570     0.549193 
  679.128     0.555526     0.540507     0.550780     0.578317     0.552757     0.529724     0.541409     0.588996     0.547197     0.484188     0.522863     0.590215     0.545200 
  679.630     0.557566     0.538408     0.554179     0.581520     0.555845     0.521321     0.540112     0.590799     0.549753     0.474005     0.520700     0.590687     0.543564 
  680.132     0.558019     0.537390     0.556163     0.583840     0.558320     0.515553     0.540715     0.591180     0.550482     0.466478     0.521788     0.590088     0.542153 
  680.634     0.561353     0.537362     0.557763     0.585246     0.559385     0.512226     0.543590     0.589246     0.550578     0.462525     0.525385     0.586482     0.540903 
  681.136     0.562999     0.539011     0.561797     0.585422     0.560349     0.510196     0.548459     0.586361     0.551599     0.460124     0.530323     0.583125     0.539324 
  681.638     0.564085     0.539246     0.562934     0.583818     0.562861     0.507538     0.549673     0.582810     0.552663     0.454690     0.529510     0.578433     0.539169 
  682.139     0.560703     0.533873     0.557452     0.579220     0.559804     0.498842     0.544757     0.576905     0.551169     0.438639     0.514235     0.574458     0.538468 
  682.641     0.546167     0.517887     0.540242     0.567855     0.549804     0.478432     0.525777     0.567492     0.545669     0.407864     0.478593     0.566500     0.534753 
  683.143     0.516589     0.481449     0.501099     0.542274     0.526131     0.438484     0.484760     0.548133     0.531617     0.356827     0.415854     0.553892     0.528397 
  683.645     0.459523     0.422047     0.438913     0.496134     0.481005     0.376997     0.417605     0.514234     0.501388     0.290208     0.333175     0.532428     0.512144 
  684.146     0.382776     0.344489     0.358253     0.430492     0.417852     0.302795     0.335949     0.463020     0.451706     0.220576     0.249663     0.492394     0.480725 
  684.648     0.303719     0.263494     0.271196     0.349852     0.335271     0.227700     0.251563     0.392774     0.380519     0.158659     0.176901     0.435482     0.429511 
  685.150     0.220644     0.191046     0.196951     0.265803     0.254044     0.162710     0.179125     0.312513     0.302225     0.109763     0.121758     0.361965     0.361170 
  685.652     0.161631     0.137494     0.142296     0.200392     0.191292     0.117050     0.127941     0.243565     0.231292     0.077812     0.086363     0.288958     0.291991 
  686.153     0.114322     0.094761     0.096569     0.141039     0.131001     0.080245     0.087569     0.175875     0.163502     0.052971     0.058818     0.216191     0.217506 
  686.655     0.078380     0.067025     0.069964     0.100551     0.094782     0.057040     0.062053     0.128095     0.119648     0.037724     0.041942     0.159322     0.160213 
  687.157     0.055900     0.046222     0.048071     0.070438     0.065960     0.039708     0.043220     0.090111     0.082061     0.026575     0.029764     0.112185     0.112684 
  687.658     0.040711     0.033873     0.034648     0.050671     0.045890     0.028855     0.030787     0.065178     0.058212     0.019553     0.021643     0.081760     0.080552 
  688.160     0.027781     0.023995     0.025003     0.035280     0.032872     0.020611     0.021804     0.045605     0.041437     0.013889     0.015687     0.057005     0.055798 
  688.662     0.020679     0.017115     0.017999     0.025655     0.023749     0.014871     0.015896     0.032616     0.028894     0.010356     0.011679     0.040399     0.039033 
  689.163     0.015393     0.013020     0.013590     0.019192     0.017338     0.011187     0.012281     0.024361     0.021256     0.007861     0.008965     0.030004     0.028493 
  689.665     0.011098     0.009823     0.010312     0.014046     0.013084     0.008595     0.008937     0.017850     0.015925     0.005882     0.006790     0.021904     0.020821 
  690.166     0.008983     0.007640     0.007870     0.010856     0.009816     0.006797     0.007070     0.013637     0.011718     0.004701     0.005387     0.016550     0.015455 
  690.668     0.006887     0.005871     0.006212     0.008248     0.007645     0.005135     0.005384     0.010330     0.008915     0.003688     0.004197     0.012600     0.011640 
  691.169     0.005132     0.004589     0.004790     0.006469     0.006020     0.004003     0.004334     0.007913     0.007051     0.002849     0.003453     0.009636     0.008891 
  691.671     0.004121     0.003668     0.003841     0.005136     0.004861     0.003002     0.003377     0.006242     0.005249     0.002356     0.002708     0.007470     0.006610 
  692.172     0.003155     0.002750     0.003152     0.004071     0.003846     0.002564     0.002827     0.004819     0.004210     0.001650     0.002177     0.005820     0.005148 
  692.674     0.002620     0.002139     0.002459     0.003225     0.003047     0.002086     0.002011     0.004011     0.003378     0.001524     0.001811     0.004474     0.004043 
  693.175     0.002337     0.001801     0.001962     0.002704     0.002218     0.001629     0.001943     0.003065     0.002647     0.001134     0.001385     0.003500     0.003262 
  693.677     0.001585     0.001626     0.001676     0.002174     0.001730     0.001238     0.001253     0.002453     0.002148     0.000884     0.001169     0.002990     0.002504 
  694.178     0.001250     0.001363     0.001331     0.001779     0.001620     0.001271     0.001064     0.001972     0.001716     0.000474     0.001027     0.002425     0.002044 
  694.679     0.001072     0.000900     0.001106     0.001391     0.001278     0.000857     0.000990     0.001769     0.001442     0.000243     0.000917     0.001899     0.001658 
  695.181     0.000986     0.000836     0.000864     0.001151     0.001071     0.000870     0.000802     0.001434     0.001029     0.000108     0.000418     0.001629     0.001435 
  695.682     0.000822     0.000810     0.000513     0.001058     0.000968     0.000373     0.000423     0.001122     0.001047     0.000185     0.000385     0.001311     0.000972 
  696.183     0.000071    -0.000003     0.000064     0.000946     0.000449     0.000176     0.000056     0.000901     0.000519     0.000182     0.000431     0.001057     0.000590 
  696.685     0.000190     0.000096     0.000591     0.000828     0.000792     0.000223     0.000290     0.000970     0.000094     0.000130     0.000506     0.000937     0.000496 
  697.186     0.000176     0.000127     0.000156     0.000039     0.000092     0.000197     0.000192     0.000453     0.000509     0.000093     0.000372     0.000846     0.000093 
  697.687     0.000118     0.000097     0.000192     0.000214     0.000230     0.000168     0.000189     0.000485     0.000143     0.000069     0.000214     0.000421     0.000156 
  698.189     0.000116     0.000095     0.000156     0.000195     0.000179     0.000161     0.000175     0.000041     0.000153     0.000073     0.000144     0.000073     0.000148 
  698.690     0.000115     0.000106     0.000114     0.000197     0.000138     0.000195     0.000107     0.000030     0.000171     0.000056     0.000094     0.000135     0.000150 
  699.191     0.000065     0.000097     0.000092     0.000139     0.000115     0.000104     0.000136     0.000139     0.000145     0.000033     0.000091     0.000149     0.000122 
  702.198     0.000107     0.000092     0.000101     0.000118     0.000114     0.000073     0.000094     0.000129     0.000123     0.000032     0.000082     0.000141     0.000134 
  705.205     0.000037     0.000029     0.000033     0.000035     0.000035     0.000020     0.000031     0.000037     0.000036     0.000005     0.000025     0.000039     0.000040 
  708.211     0.000010     0.000012     0.000012     0.000013     0.000010     0.000002     0.000007     0.000012     0.000010    -0.000001     0.000010     0.000012     0.000012 
  711.216     0.000000     0.000001     0.000001    -0.000001     0.000001     0.000003     0.000001     0.000001     0.000000     0.000001    -0.000001     0.000005     0.000001 
  714.220     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
  717.224     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001 
  720.228     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000     0.000001     0.000001    -0.000001     0.000000     0.000000     0.000000     0.000001 
  723.230     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001    -0.000001     0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001 
  726.232     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000     0.000000 
  729.234     0.000000     0.000000     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000000 
  732.234    -0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000001    -0.000000    -0.000000     0.000000    -0.000000 
  735.235     0.000000    -0.000000     0.000001     0.000001     0.000000     0.000000    -0.000001     0.000000    -0.000001    -0.000000    -0.000000     0.000001    -0.000000 
  738.234     0.000001    -0.000000     0.000001     0.000001     0.000000     0.000001     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000 
  741.233     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000000    -0.000000 
  744.231     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000001 
  747.228     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000001    -0.000001     0.000000    -0.000000    -0.000000    -0.000001 
  750.225    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000001    -0.000001    -0.000001    -0.000000    -0.000000     0.000000     0.000000    -0.000001 
  753.221    -0.000000    -0.000000     0.000000     0.000000     0.000001     0.000000    -0.000001    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000001 
  756.272     0.000001     0.000001    -0.000000     0.000001     0.000000     0.000000    -0.000001    -0.000000    -0.000001    -0.000000     0.000001     0.000000    -0.000001 
  759.267    -0.000000     0.000001    -0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000001    -0.000001    -0.000000     0.000001    -0.000000    -0.000001 
  762.261     0.000000     0.000000     0.000000     0.000001     0.000000     0.000001    -0.000001    -0.000000    -0.000001    -0.000001     0.000000     0.000000    -0.000000 
  765.254    -0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000001     0.000000     0.000000     0.000001     0.000001     0.000001    -0.000000 
  768.247    -0.000000    -0.000000     0.000001     0.000001    -0.000001     0.000001     0.000000    -0.000001    -0.000001     0.000001     0.000001     0.000000    -0.000000 
  771.294     0.000000     0.000001     0.000001     0.000001    -0.000000     0.000000    -0.000000    -0.000001    -0.000001     0.000000     0.000001     0.000000     0.000000 
  774.286     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000001     0.000001    -0.000000 
  777.277     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000001    -0.000000    -0.000000    -0.000001     0.000001     0.000001     0.000001 
  780.266    -0.000000     0.000001     0.000001     0.000001     0.000001    -0.000000    -0.000001    -0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001 
  783.311     0.000000     0.000000     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000001    -0.000000     0.000000     0.000000     0.000001 
  786.300    -0.000000     0.000001     0.000001     0.000000     0.000001    -0.000000    -0.000000     0.000000    -0.000000     0.000001     0.000001     0.000001     0.000001 
  789.288     0.000000     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001    -0.000001     0.000002     0.000001     0.000001     0.000001 
  792.275     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001    -0.000000     0.000002     0.000001     0.000002     0.000001 
  795.316     0.000001     0.000002     0.000001     0.000002     0.000002     0.000002     0.000001     0.000002     0.000008     0.000007     0.000001     0.000002     0.000002 
  798.302     0.000000     0.000002     0.000002     0.000002     0.000001     0.000002     0.000001     0.000001     0.000000     0.000000     0.000001     0.000001     0.000002 
  801.287     0.000000     0.000000     0.000001     0.000001     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001 
  804.327     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  807.310    -0.000000     0.000001     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  810.348    -0.000000     0.000000     0.000000     0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  813.331     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  816.312     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000000 
  819.348     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001    -0.000001     0.000000     0.000000     0.000000 
  822.328     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000001    -0.000000     0.000000    -0.000000    -0.000000 
  825.362     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  828.341    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000 
  831.374    -0.000000     0.000000    -0.000000     0.000000     0.000001     0.000000    -0.000000    -0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000 
  834.351    -0.000000     0.000000    -0.000000     0.000000     0.000001    -0.000000    -0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000 
  837.382    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  840.357    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  843.387    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  846.361    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  849.389    -0.000000    -0.000000    -0.000001    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  852.362    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000001 
  855.389     0.000000     0.000001    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  858.359     0.000000    -0.000000    -0.000000     0.000000     0.000001     0.000000     0.000000     0.000001    -0.000000     0.000000     0.000000     0.000000     0.000000 
  861.385    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000001     0.000000    -0.000000    -0.000000     0.000000 
  864.409     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  867.378    -0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000    -0.000001 
  870.400    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000001     0.000000     0.000000    -0.000000    -0.000000 
  873.422    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000001    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  876.389    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000001    -0.000000     0.000001     0.000000    -0.000000    -0.000000 
  879.409     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  882.428     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000001     0.000000    -0.000000 
  885.447     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000001     0.000001     0.000001     0.000000    -0.000000 
  888.410     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000001     0.000001     0.000001     0.000004    -0.000000 
  891.427     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000004    -0.000000     0.000001     0.000000     0.000006     0.000000 
  894.444     0.000001     0.000001     0.000004     0.000002     0.000001     0.000001     0.000004     0.000001     0.000001     0.000001     0.000001     0.000000     0.000000 
  897.459     0.000001     0.000002    -0.000000     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 
  900.419     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000002     0.000000     0.000001 
  903.433     0.000001     0.000001     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000001     0.000001     0.000000     0.000001 
  906.446     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
  909.458     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000 
  912.469     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000004     0.000000     0.000000     0.000000     0.000005     0.000000 
  915.480     0.000000     0.000000     0.000002     0.000004     0.000002     0.000000     0.000000     0.000006     0.000000     0.000002     0.000000     0.000008     0.000002 
  918.489     0.000004     0.000003     0.000003     0.000007     0.000004     0.000002     0.000003     0.000007     0.000003     0.000001     0.000003     0.000006     0.000003 
  921.443     0.000006     0.000005     0.000006     0.000007     0.000007     0.000004     0.000005     0.000004     0.000006     0.000004     0.000004     0.000003     0.000004 
  924.451     0.000005     0.000007     0.000007     0.000003     0.000007     0.000005     0.000007     0.000000     0.000007     0.000004     0.000007     0.000000     0.000007 
  927.458     0.000003     0.000005     0.000002     0.000001     0.000003     0.000005     0.000004     0.000000     0.000004     0.000004     0.000005     0.000000     0.000005 
  930.465     0.000000     0.000002     0.000000    -0.000000     0.000000     0.000003     0.000000     0.000000     0.000000     0.000003     0.000001     0.000000     0.000002 
  933.470     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001    -0.000000     0.000000 
  936.475     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000001     0.000000    -0.000000     0.000000 
  939.478     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  942.481     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  945.483     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  948.484     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
  951.484     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  954.538     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  957.537     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000 
  960.534     0.000000    -0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  963.531     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
  966.526     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000    -0.000000 
  969.521     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
  972.515     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000 
  975.563     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000    -0.000000     0.000000 
  978.555     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
  981.546     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000 
  984.537    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  987.580     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
  990.569     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000     0.000000 
  993.556     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000 
  996.543     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
  999.583     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1002.568    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1005.552     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000 
 1008.589     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1011.571     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1014.606     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1017.587     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1020.620     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1023.598     0.000000     0.000000     0.000001     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1026.629     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1029.606     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1032.635     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1035.610     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1038.637     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1041.610     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1044.635     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1047.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1050.629     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1053.652     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1056.620     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1059.640     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1062.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1065.678     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1068.642     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1071.658     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1074.674     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1077.688     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1080.702     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1083.660     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1086.672     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1089.682     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1092.691     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1095.699     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1098.707     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1101.713     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1104.718     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1107.722     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1110.725     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1113.727     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1116.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1119.728     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1122.726     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1125.724     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
 1128.720     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1131.770     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1134.764     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1137.757     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
 1140.749     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1143.741     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1146.784     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1149.773     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000 
 1152.761     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1155.801     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000 
 1158.786     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1161.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1164.807     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1167.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1170.771     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000 
 1173.804     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1176.783     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1179.814     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000 
 1182.790     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000     0.000000 
 1185.819     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000 
 1188.793     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000    -0.000000     0.000000    -0.000000    -0.000000 
 1191.820     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
 1194.845     0.000000     0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1197.815    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000    -0.000000    -0.000000     0.000000     0.000000     0.000000    -0.000000 
 1200.838    -0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000     0.000000    -0.000000     0.000000     0.000000    -0.000000 
