# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 78
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       2.110000     1.490000     1.490000     2.110000     2.500000     1.320000     1.320000     2.500000 
# z_pos      57.000000    56.000000    56.000000    57.000000    58.000000    55.000000    55.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       421          422          423          424          425          426          427          428      
#
# lambda for peak transmission
#          497.8990000  494.9130000  497.8990000  497.8990000  497.8990000  494.9130000  494.9130000  494.9130000 
# peak transmission
#            0.7486600    0.7497865    0.7489319    0.7493929    0.7468365    0.7468434    0.7471444    0.7464318 
# lambda blue with 1/2 of peak transmission
#          411.5971521  411.4970451  411.5750741  411.6544751  409.7758483  409.8523388  409.8655076  409.8290264 
# lambda red  with 1/2 of peak transmission
#          545.0157772  544.9326265  545.0112629  545.0830230  542.6248838  542.8252999  542.8266341  542.6169340 
# half width                              
#          133.4186251  133.4355814  133.4361888  133.4285478  132.8490355  132.9729611  132.9611265  132.7879077 
# central wavelength                      
#          478.3064647  478.2148358  478.2931685  478.3687491  476.2003660  476.3388194  476.3460708  476.2229802 
# central wavelength calculated as SAGEM (mean frequency)
#          469.0025294  468.9067523  468.9865247  469.0646414  466.9349037  467.0587609  467.0678054  466.9664821 
# lambda blue with 80% of peak transmission
#          413.6851626  413.6333936  413.6763477  413.7243495  412.6841596  412.7630699  412.7731267  412.7403032 
# lambda red  with 80% of peak transmission
#          543.0964636  543.0283207  543.0991699  543.1549467  540.5593453  540.6861161  540.6953903  540.5621222 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7158661    0.7166341    0.7162136    0.7161709    0.7156124    0.7160994    0.7168766    0.7149466 
# ATB calculated from points above 50%
#            0.7158661    0.7166341    0.7162136    0.7161709    0.7104676    0.7107253    0.7114512    0.7096570 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 476.200366 at column =  6, at id = 425 
# maxCWL      = 478.368749 at column =  5, at id = 424 
# difference =    2.1683830 
# minBW       = 132.787908 at column =  9, at id = 428 
# maxBW       = 133.436189 at column =  4, at id = 423 
# difference =    0.6482811 
# minATB80    = 0.714947 at column =  9, at id = 428 
# maxATB80    = 0.716877 at column =  8, at id = 427 
# difference =    0.0019299 
# minBlueEdge = 409.775848 at column =  6, at id = 425 
# maxBlueEdge = 411.654475 at column =  5, at id = 424 
# difference =    1.8786268 
# minRedEdge  = 542.616934 at column =  9, at id = 428 
# maxRedEdge  = 545.083023 at column =  5, at id = 424 
# difference =    2.4660889 
# minABR      = 9.999900 at column =  2, at id = 421 
# maxABR      = 9.999900 at column =  2, at id = 421 
# difference =    0.0000000 
  380.788     0.000005     0.000002     0.000004     0.000003     0.000003    -0.000000     0.000002     0.000003 
  383.789     0.000002     0.000003     0.000002    -0.000001     0.000004     0.000000     0.000004     0.000001 
  386.789     0.000003     0.000004     0.000002     0.000001     0.000003     0.000002     0.000003     0.000004 
  389.790     0.000005     0.000003     0.000005     0.000002     0.000005     0.000015     0.000003     0.000005 
  392.790     0.000039     0.000027     0.000033     0.000036     0.000047     0.000046     0.000046     0.000041 
  395.790     0.000078     0.000068     0.000068     0.000060     0.000120     0.000127     0.000117     0.000130 
  398.789     0.000260     0.000263     0.000261     0.000246     0.000659     0.000651     0.000648     0.000659 
  401.788     0.001440     0.001516     0.001452     0.001384     0.003328     0.003243     0.003192     0.003255 
  404.787     0.006939     0.007368     0.007044     0.006697     0.019124     0.017962     0.017802     0.018560 
  407.785     0.050248     0.054062     0.051183     0.048409     0.145322     0.138477     0.137436     0.140644 
  410.783     0.286755     0.299712     0.289773     0.280042     0.488810     0.479187     0.477707     0.481760 
  413.781     0.609237     0.615371     0.610336     0.605667     0.660158     0.658285     0.658492     0.658496 
  416.834     0.680851     0.682568     0.681339     0.681740     0.674874     0.674747     0.674677     0.673751 
  419.831     0.684314     0.685684     0.684869     0.684782     0.680289     0.680129     0.679672     0.679223 
  422.828     0.683507     0.684547     0.684044     0.683954     0.679622     0.679700     0.679352     0.678762 
  425.824     0.687057     0.687618     0.686925     0.687604     0.680551     0.680695     0.680356     0.679767 
  428.820     0.687019     0.687913     0.686947     0.687423     0.686818     0.686454     0.686520     0.685861 
  431.815     0.693644     0.694020     0.694148     0.694200     0.692172     0.692086     0.691910     0.691245 
  434.810     0.694401     0.694986     0.694435     0.694585     0.686703     0.687617     0.687619     0.686339 
  437.862     0.688138     0.689103     0.688742     0.688482     0.688705     0.688017     0.689158     0.686831 
  440.856     0.704402     0.705815     0.704772     0.704435     0.707790     0.707090     0.708267     0.706809 
  443.850     0.709945     0.710743     0.710550     0.710421     0.704612     0.704822     0.706511     0.703865 
  446.844     0.707596     0.708112     0.707936     0.708349     0.696944     0.696914     0.698374     0.695790 
  449.837     0.698937     0.699488     0.699380     0.699703     0.707259     0.707885     0.708704     0.706479 
  452.830     0.710200     0.710697     0.709877     0.709992     0.705981     0.706933     0.708169     0.704916 
  455.878     0.709877     0.709349     0.710101     0.710282     0.704184     0.704506     0.705464     0.702877 
  458.870     0.708096     0.708813     0.708373     0.707978     0.714608     0.714932     0.715814     0.713505 
  461.862     0.721544     0.722954     0.722239     0.721656     0.720760     0.721835     0.722259     0.719893 
  464.853     0.728752     0.729681     0.729074     0.729030     0.726368     0.726667     0.727676     0.725309 
  467.901     0.729323     0.729776     0.729396     0.729171     0.724428     0.725105     0.726052     0.723323 
  470.891     0.730315     0.731104     0.730213     0.729781     0.729119     0.729449     0.730586     0.727847 
  473.881     0.737635     0.738226     0.737883     0.737038     0.737369     0.737408     0.738140     0.737202 
  476.871     0.744346     0.744697     0.744191     0.743760     0.737741     0.738666     0.739594     0.737520 
  479.916     0.737983     0.738084     0.737931     0.737524     0.729304     0.730651     0.731183     0.729233 
  482.905     0.739892     0.741289     0.739528     0.739052     0.743254     0.742951     0.743899     0.743016 
  485.894     0.748338     0.748505     0.747559     0.748116     0.741706     0.742528     0.742738     0.741584 
  488.882     0.744549     0.745575     0.744077     0.744757     0.741526     0.741787     0.742062     0.741590 
  491.925     0.743039     0.745833     0.744003     0.744748     0.742479     0.742991     0.743524     0.742763 
  494.913     0.747386     0.749787     0.747832     0.748438     0.746765     0.746843     0.747144     0.746432 
  497.899     0.748660     0.749626     0.748932     0.749393     0.746836     0.746142     0.747079     0.745860 
  500.942     0.745487     0.746788     0.745704     0.745963     0.744564     0.744343     0.745291     0.744075 
  503.928     0.744821     0.745480     0.744369     0.744693     0.735853     0.736744     0.737968     0.735722 
  506.913     0.735298     0.735344     0.734946     0.735322     0.729505     0.729819     0.730815     0.728878 
  509.954     0.732217     0.733032     0.733600     0.732254     0.739392     0.740191     0.740815     0.740025 
  512.939     0.734241     0.735778     0.735522     0.734701     0.728374     0.730094     0.731074     0.729078 
  515.923     0.716791     0.717383     0.718016     0.717112     0.706284     0.708616     0.708904     0.706411 
  518.963     0.706387     0.708207     0.707730     0.706357     0.710808     0.711619     0.712600     0.709969 
  521.946     0.718969     0.720243     0.719705     0.718963     0.720533     0.721140     0.722121     0.719473 
  524.929     0.727322     0.727990     0.728027     0.727212     0.724037     0.724226     0.725545     0.723120 
  527.967     0.726051     0.726389     0.726589     0.726043     0.725118     0.725265     0.726421     0.723686 
  530.949     0.729648     0.730379     0.730063     0.729545     0.732591     0.731911     0.733794     0.731548 
  533.987     0.737277     0.737567     0.737379     0.737761     0.735158     0.734097     0.735624     0.734091 
  536.968     0.738403     0.738971     0.739035     0.738963     0.736554     0.735833     0.737656     0.736656 
  539.948     0.735939     0.735205     0.736181     0.736828     0.663782     0.674783     0.676319     0.664071 
  542.984     0.612089     0.605064     0.612679     0.619447     0.334465     0.356800     0.357022     0.333214 
  545.964     0.263369     0.253068     0.262515     0.271973     0.082074     0.090975     0.091049     0.081935 
  548.999     0.058102     0.054791     0.057364     0.060121     0.016836     0.018934     0.018856     0.016813 
  551.977     0.012376     0.011573     0.012195     0.012810     0.003227     0.003632     0.003631     0.003237 
  555.012     0.002383     0.002274     0.002365     0.002457     0.000940     0.001034     0.001031     0.000934 
  557.989     0.000790     0.000775     0.000798     0.000812     0.000343     0.000378     0.000380     0.000342 
  561.023     0.000287     0.000278     0.000289     0.000295     0.000136     0.000148     0.000145     0.000133 
  563.999     0.000120     0.000115     0.000121     0.000121     0.000053     0.000061     0.000060     0.000054 
  567.032     0.000042     0.000047     0.000042     0.000052     0.000027     0.000025     0.000024     0.000023 
  570.007     0.000021     0.000024     0.000022     0.000022     0.000012     0.000018     0.000016     0.000014 
  573.038     0.000013     0.000014     0.000013     0.000013     0.000002     0.000003     0.000005     0.000002 
  576.013     0.000004     0.000001     0.000002     0.000002     0.000002     0.000003     0.000002     0.000002 
  579.043     0.000000     0.000002     0.000002     0.000002     0.000002    -0.000000     0.000002     0.000002 
  582.017     0.000002     0.000002     0.000002     0.000002     0.000001     0.000002     0.000002     0.000002 
  585.046     0.000001     0.000002     0.000001     0.000002     0.000001     0.000001     0.000001     0.000002 
  588.019     0.000001     0.000002     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  591.047     0.000001     0.000001     0.000000     0.000001     0.000000     0.000001     0.000001     0.000001 
  594.019     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000001 
  597.046     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000 
  600.073     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000000     0.000001 
  603.043     0.000001     0.000001     0.000000     0.000001     0.000001     0.000001     0.000001     0.000000 
  606.068     0.000001     0.000001     0.000000     0.000001     0.000000     0.000000     0.000001     0.000000 
  609.038     0.000001     0.000001    -0.000000     0.000000     0.000001     0.000001     0.000001     0.000001 
  612.062     0.000001     0.000001     0.000000     0.000000     0.000000     0.000001     0.000000     0.000000 