# number of points on sci filter + aux + bad z = 8
# number of points on sci filter               = 8
# number of positions in lambda                = 81
# noof scans  1            1            1            1            1            1            1            1          
# x_pos      25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000     0.000000 
# y_pos       0.000000    25.000000     0.000000   -25.000000     0.000000    50.000000     0.000000   -50.000000 
# angle       1.490000     1.490000     2.110000     2.110000     1.320000     1.320000     2.500000     2.500000 
# z_pos      56.000000    56.000000    57.000000    57.000000    55.000000    55.000000    58.000000    58.000000 
# r_pos      25.000000    25.000000    25.000000    25.000000    50.000000    50.000000    50.000000    50.000000 
# phi         0.000000     1.570796     3.141593     4.712204     0.000000     1.570796     3.141593     4.712204 
# gnupl col      2            3            4            5            6            7            8            9      
# pos_id       321          322          323          324          325          326          327          328      
#
# lambda for peak transmission
#          572.0280000  575.0030000  572.0280000  572.0280000  572.0280000  566.0210000  572.0280000  568.9970000 
# peak transmission
#            0.7594247    0.7597104    0.7597699    0.7593810    0.7593896    0.7594267    0.7597831    0.7556116 
# lambda blue with 1/2 of peak transmission
#          550.5021424  550.5987578  550.4955087  550.5351561  550.4608508  551.0411247  550.4524043  552.1825471 
# lambda red  with 1/2 of peak transmission
#          697.1871430  698.5325415  697.0502724  695.8522188  697.6437710  700.2808212  697.1845104  696.8590810 
# half width                              
#          146.6850005  147.9337838  146.5547637  145.3170626  147.1829202  149.2396965  146.7321061  144.6765339 
# central wavelength                      
#          623.8446427  624.5656497  623.7728905  623.1936874  624.0523109  625.6609729  623.8184574  624.5208141 
# central wavelength calculated as SAGEM (mean frequency)
#          615.2221076  615.8058002  615.1646698  614.7223851  615.3740272  616.7613899  615.1900212  616.1418702 
# lambda blue with 80% of peak transmission
#          553.0278934  553.1475574  553.0266146  553.0428585  553.0111595  553.5444165  553.0057266  554.6741206 
# lambda red  with 80% of peak transmission
#          693.4134873  694.7128452  693.2374992  692.2959304  693.8348224  696.4659035  693.3775628  693.1597588 
# lambda blue with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# lambda red  with 0.0001 of peak transmission
#         9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 9999.0000000 
# ATB calculated from points above 80%
#            0.7284022    0.7286370    0.7276434    0.7283031    0.7287521    0.7260291    0.7282494    0.7263019 
# ATB calculated from points above 50%
#            0.7185113    0.7134599    0.7176176    0.7162336    0.7193779    0.7225954    0.7184510    0.7186996 
# ABR calculated from points below and above 0.0001
#            9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000    9.9999000 
# minCWL      = 623.193687 at column =  5, at id = 324 
# maxCWL      = 625.660973 at column =  7, at id = 326 
# difference =    2.4672855 
# minBW       = 144.676534 at column =  9, at id = 328 
# maxBW       = 149.239697 at column =  7, at id = 326 
# difference =    4.5631626 
# minATB80    = 0.726029 at column =  7, at id = 326 
# maxATB80    = 0.728752 at column =  6, at id = 325 
# difference =    0.0027230 
# minBlueEdge = 550.452404 at column =  8, at id = 327 
# maxBlueEdge = 552.182547 at column =  9, at id = 328 
# difference =    1.7301428 
# minRedEdge  = 695.852219 at column =  5, at id = 324 
# maxRedEdge  = 700.280821 at column =  7, at id = 326 
# difference =    4.4286024 
# minABR      = 9.999900 at column =  2, at id = 321 
# maxABR      = 9.999900 at column =  2, at id = 321 
# difference =    0.0000000 
  499.928     0.000001     0.000001     0.000001     0.000000     0.000000     0.000002    -0.000000    -0.000000 
  502.914     0.000002     0.000001     0.000001     0.000001     0.000001     0.000002     0.000001     0.000001 
  505.899     0.000002     0.000002     0.000000     0.000001     0.000001     0.000002     0.000001     0.000001 
  508.941     0.000002     0.000002     0.000001     0.000001     0.000001     0.000001     0.000001     0.000000 
  511.925     0.000002     0.000002     0.000007     0.000001     0.000002     0.000002     0.000001     0.000002 
  514.909     0.000009     0.000015     0.000013     0.000007     0.000013     0.000014     0.000009     0.000002 
  517.949     0.000015     0.000019     0.000019     0.000016     0.000017     0.000016     0.000019     0.000014 
  520.933     0.000025     0.000026     0.000023     0.000019     0.000023     0.000025     0.000024     0.000016 
  523.972     0.000051     0.000050     0.000051     0.000052     0.000048     0.000044     0.000051     0.000033 
  526.954     0.000112     0.000112     0.000111     0.000107     0.000115     0.000098     0.000111     0.000069 
  529.936     0.000239     0.000236     0.000232     0.000222     0.000244     0.000218     0.000233     0.000150 
  532.974     0.000452     0.000464     0.000437     0.000420     0.000467     0.000464     0.000448     0.000270 
  535.955     0.001117     0.001061     0.001097     0.001094     0.001127     0.000940     0.001098     0.000651 
  538.992     0.003457     0.003190     0.003449     0.003634     0.003450     0.002715     0.003427     0.001790 
  541.972     0.012057     0.011833     0.011933     0.011169     0.012363     0.010225     0.012034     0.006417 
  544.952     0.036996     0.036254     0.037091     0.035747     0.038084     0.033221     0.037604     0.018100 
  547.987     0.134488     0.126448     0.136671     0.136842     0.136736     0.108106     0.138297     0.063755 
  550.966     0.424938     0.415487     0.425502     0.420752     0.429306     0.372876     0.430221     0.247282 
  554.000     0.693630     0.682902     0.693937     0.693572     0.693675     0.649005     0.694401     0.572800 
  556.978     0.737752     0.740377     0.735880     0.738089     0.738478     0.741854     0.735234     0.712790 
  560.012     0.757013     0.752499     0.756179     0.758318     0.755244     0.741409     0.754765     0.750743 
  562.988     0.756516     0.757758     0.756449     0.753003     0.757102     0.757933     0.755947     0.748293 
  566.021     0.759011     0.758829     0.758931     0.758964     0.758568     0.759427     0.758622     0.750054 
  568.997     0.758772     0.757259     0.758177     0.758768     0.757942     0.754972     0.757793     0.755612 
  572.028     0.759425     0.758979     0.759770     0.759381     0.759390     0.755758     0.759783     0.754019 
  575.003     0.758599     0.759710     0.758834     0.756805     0.759061     0.758246     0.759580     0.753539 
  578.033     0.755528     0.757679     0.755160     0.752407     0.756316     0.757761     0.756092     0.750115 
  581.007     0.754014     0.755529     0.753726     0.753718     0.754435     0.755412     0.754373     0.748034 
  584.037     0.751247     0.754367     0.750739     0.747435     0.752177     0.754961     0.751762     0.746571 
  587.010     0.751641     0.753032     0.751051     0.753137     0.751833     0.752380     0.751837     0.745150 
  590.038     0.749522     0.750661     0.749084     0.750431     0.750031     0.750160     0.749346     0.748848 
  593.010     0.748777     0.748944     0.748191     0.750072     0.749181     0.747355     0.748158     0.747075 
  596.037     0.745027     0.745213     0.744399     0.746377     0.745051     0.745737     0.743929     0.743854 
  599.064     0.746178     0.745570     0.745516     0.747090     0.746328     0.743968     0.745715     0.743638 
  602.034     0.741092     0.741514     0.739959     0.741282     0.741263     0.743620     0.740280     0.741260 
  605.060     0.742800     0.740618     0.742597     0.745642     0.743013     0.738400     0.743269     0.738511 
  608.085     0.747031     0.745510     0.746204     0.748172     0.747038     0.744657     0.747406     0.744997 
  611.054     0.744077     0.743281     0.743328     0.745648     0.744196     0.743590     0.744602     0.744079 
  614.078     0.741682     0.741831     0.741402     0.743690     0.742676     0.741148     0.742259     0.740958 
  617.046     0.740922     0.740844     0.740812     0.741888     0.741731     0.741048     0.741364     0.739206 
  620.069     0.739425     0.739899     0.738871     0.739625     0.740017     0.740409     0.739518     0.737169 
  623.091     0.735243     0.735947     0.735208     0.736917     0.736080     0.736696     0.735606     0.733864 
  626.057     0.735113     0.735173     0.734930     0.737275     0.735338     0.734694     0.735746     0.732113 
  629.079     0.735706     0.735798     0.736146     0.738318     0.735972     0.734693     0.736724     0.734404 
  632.100     0.732846     0.733790     0.733425     0.735092     0.733663     0.733846     0.733853     0.733472 
  635.120     0.729721     0.730173     0.729720     0.731771     0.730653     0.730985     0.730725     0.729225 
  638.084     0.728868     0.729266     0.728193     0.729962     0.728706     0.729476     0.728984     0.727724 
  641.103     0.724682     0.725515     0.723598     0.726209     0.724599     0.726730     0.724115     0.724567 
  644.121     0.722827     0.722221     0.721830     0.725585     0.722434     0.721798     0.721891     0.720871 
  647.084     0.724292     0.724609     0.723420     0.725708     0.724507     0.722953     0.723860     0.723000 
  650.101     0.720954     0.720771     0.719367     0.722032     0.721070     0.722324     0.720106     0.720991 
  653.118     0.716952     0.716794     0.715288     0.717497     0.717570     0.717526     0.716430     0.717373 
  656.134     0.710958     0.711358     0.709172     0.711153     0.711517     0.714554     0.710223     0.710870 
  659.150     0.711788     0.708740     0.710273     0.714482     0.710926     0.707919     0.711114     0.709377 
  662.109     0.714632     0.714735     0.713409     0.713108     0.714690     0.713353     0.714665     0.712044 
  665.124     0.708280     0.709435     0.707341     0.709120     0.708802     0.713296     0.708231     0.705434 
  668.138     0.709728     0.709667     0.709056     0.710310     0.709664     0.709409     0.709756     0.706844 
  671.151     0.702633     0.704445     0.701045     0.701760     0.702838     0.706578     0.701786     0.703005 
  674.164     0.694296     0.695674     0.693181     0.696242     0.694823     0.695212     0.693823     0.693167 
  677.120     0.693773     0.692960     0.692332     0.696949     0.693588     0.691105     0.693491     0.692357 
  680.132     0.692554     0.690955     0.691362     0.694724     0.691966     0.689220     0.691978     0.692591 
  683.143     0.690189     0.688723     0.689739     0.693085     0.690044     0.686152     0.690243     0.689461 
  686.153     0.687641     0.688294     0.686398     0.687482     0.687953     0.687227     0.687645     0.686538 
  689.163     0.680640     0.682072     0.679137     0.677953     0.681765     0.684176     0.680743     0.678707 
  692.172     0.651467     0.666729     0.647008     0.614598     0.657988     0.676949     0.650500     0.647382 
  695.181     0.545000     0.596905     0.536328     0.442370     0.566647     0.644506     0.543989     0.516719 
  698.189     0.297168     0.412687     0.284583     0.161478     0.338306     0.557971     0.297619     0.267714 
  701.196     0.065392     0.125309     0.061157     0.028171     0.083147     0.301725     0.065927     0.058596 
  704.203     0.014268     0.023618     0.013387     0.008179     0.017079     0.064892     0.014114     0.011475 
  707.209     0.006380     0.009075     0.005935     0.003757     0.007284     0.017095     0.006210     0.004899 
  710.214     0.002160     0.003591     0.001989     0.001070     0.002594     0.007573     0.002104     0.001827 
  713.219     0.000558     0.000907     0.000516     0.000314     0.000663     0.002233     0.000543     0.000461 
  716.223     0.000243     0.000333     0.000228     0.000155     0.000270     0.000631     0.000235     0.000184 
  719.227     0.000128     0.000175     0.000120     0.000080     0.000144     0.000296     0.000125     0.000099 
  722.230     0.000052     0.000078     0.000048     0.000031     0.000058     0.000142     0.000051     0.000044 
  725.232     0.000023     0.000035     0.000025     0.000021     0.000028     0.000058     0.000023     0.000020 
  728.233     0.000024     0.000025     0.000016     0.000016     0.000021     0.000029     0.000022     0.000019 
  731.234     0.000011     0.000021     0.000015     0.000012     0.000015     0.000022     0.000016     0.000013 
  734.235     0.000002     0.000003     0.000002     0.000001     0.000001     0.000016     0.000000     0.000001 
  737.234     0.000003     0.000003     0.000001     0.000001     0.000002     0.000001     0.000001     0.000001 
  740.233     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001     0.000001 
